Page 31

Using ESP

Menu Toolbar File > New Whenever New is selected from the File menu, the default configuration of ESP is loaded.

Open / Save When Save or Save As is selected, the ESP configuration is saved to the host computer’s hard drive and available whenever the same file is selected under Open. When you save menu changes to your hard drive, these changes are not saved to your imager. The diagram below shows how settings can be saved and received between ESP and the imager, and ESP and the host hard drive.

(Save to Imager)

(Receive Reader Settings)

Import / Export Import converts the ASCII settings from a text file to ESP configuration settings. Export converts the active ESP configuration settings to an ASCII text file.

MS-Q Imager User’s Manual

2-5

Page 32

Menu Toolbar

Model The Model menu allows you to select between reader models. When you choose another model, the current connection with your present model will be terminated.

New Model To connect to another model, select New Model, choose the model you want, and click OK. All models you have selected and enabled will continue to appear in the dropdown model menu. The New Model option is repeated when you click the Switch Model button on the top row of icons.

2-6

MS-Q Imager User’s Manual

Page 33

Using ESP

Options You can use the Options menu to save memos and set up ESP preferences. Preferences will be saved and loaded into ESP the next time ESP is opened, whether or not you save the ESP file to the host computer.

Preferences > General Tab

Reload Last File At startup, reloads the last file saved to the computer.

Show Model Prompt At startup, remembers the last connected model and displays it in the Connecting... dialog whenever you attempt to connect.

Skip EZ Mode At startup, skips EZ Mode and opens directly in App Mode.

Show Connect Prompt At startup, displays the Would you like to connect... prompt.

Receive After Connect At startup, loads the imager’s settings into ESP. (This is not recommended if you want to preserve your ESP settings for future use.)

Show Both Icon and Text (Default) Sets the toolbar to display icons and names of all operations.

Only Show Icon Sets the toolbar to display only icons representing operations, without text.

Only Show Text Sets the toolbar to display names of operations only, without icons. MS-Q Imager User’s Manual

2-7

Page 34

Menu Toolbar

Terminal Tab When Show Non-Printable Characters is checked, characters such as ‘CRLF’ will be displayed in the terminal window. When the Enhanced Format radio button is checked, subscript and superscript formatting is shown. When Display incoming data even when not in focus is checked, data from the imager will continue to appear in the terminal even when ESP is not the top window on the host computer’s screen. When Enable Echo is checked, the terminal window displays user-entered data.

Change Keyboard Macros Clicking the Change Keyboard Macros button brings up the Function Keys dialog. In this dialog you can select the desired function key and then enter your macro keystrokes in the associated key map. For example, to make Ctrl-F2 the keystroke to send a trigger character, select F2, then in the Ctrl row, enter <trigger character> and click OK. Then whenever the Ctrl-F2 keystroke is pressed, the trigger character will start the read cycle. Note: The F1 key is reserved for opening ESP Help and the F3 key is reserved for the Find Next function.

Change Font Sets the font characteristics for data received from the imager.

Change Echo Font Sets the font characteristics of user-entered data.

2-8

MS-Q Imager User’s Manual

Page 35

Using ESP

Bar Code Options Tab

Sizing Information Sets element size (in thousands of an inch) of symbols that you create and print from the Bar Code Dialog under View.

MS-Q Imager User’s Manual

2-9

Page 36

Menu Toolbar

Advanced Tab

The Auto Sync dialog on the Advanced tab allows you to determine whether Auto Sync will be automatically enabled in sections of ESP where it is used, or if it will ask you before it enables Auto Sync functions.

Always Ask Before Auto Sync Occurs If you check this option box, you are then able to determine what specific Auto Sync functions will be enabled. Receive Settings from the Reader will automatically send the imager’s settings to ESP when Auto Sync is enabled. Send ESP Settings to the Reader will automatically send all imager configuration settings chosen in ESP to the imager. Do Not Send or Receive Settings creates a condition in which Auto Sync will not send imager settings to ESP, or send ESP settings to the imager.

Send XON with Auto-Connect Sends an XON (Begin Transmission) command to the imager before starting the Auto-Connect routine.

2-10

MS-Q Imager User’s Manual

Page 37

Using ESP

Document Memo The information you type in the Document Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Document Memo item on the Options menu.

Model Memo Similar to Document Memo, the information you type in the Model Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Model Memo item on the Options menu. Memos created in Model Memo are specific to the model enabled when the message was created.

Note: Memos must be saved in a .esp file if you want them to available in your next session. If you do not save your current session, any memos that you have entered during the session will be discarded, and will be unavailable in your next session.

MS-Q Imager User’s Manual

2-11

Page 38

Menu Toolbar

Connect

Connection Wizard When you choose to connect to the imager via the Connection Wizard, you will first need to select the correct protocol (see Select Protocol and Connect to Imager in Chapter 1, Quick Start.) When you have successfully connected to the imager you will see one of the two following displays in the status bar at the lower right of the screen: RS-232:

USB:

Settings / Options Settings allows you to set baud rate, parity, stop bits, data bits and communications port for the RS-232 interface before connecting.

Options allows you to auto-connect to the imager (RS-232), follow standard connection procedure (RS-232 and USB), and disconnect the imager from ESP (RS-232 and USB).

2-12

MS-Q Imager User’s Manual

Page 39

Using ESP

View The options in the View menu correspond to icons on the operations toolbar (Configuration, Imager, Terminal, Utilities). Each option allows you to configure the imager or to perform various other functions in the chosen view. The Imager, Terminal, and Utilities views are explained fully in later sections. The View menu also allows you to access the Barcode Dialog.

Barcode Dialog In the Barcode Dialog you can directly type the text and commands you want to encode. This allows you to create configuration symbols that you can print and read with the imager.

MS-Q Imager User’s Manual

2-13

Page 40

Send/Receive

Send/Receive To access Receive, Save, Default, and Advanced options, click the Send/Recv button.

You can also access these options by right-clicking in any of the configuration views.

Receive Reader Settings From the Send/Recv menu, select Receive Reader Settings. This option is useful if you want to receive the imager’s settings and save them as a file for later retrieval. For example, if your imager has settings that you do not want to change, choosing Receive Reader Settings will allow you to load those settings to ESP and save them as an ESP file. Receiving the imager’s settings also assures that you will not subsequently save any unwanted configuration changes previously made in ESP. Select this option if you want to upload the imager’s settings to ESP. For example, if your ESP file has a number of custom settings that you want to maintain and download to the imager, you will lose those ESP settings if you choose to receive settings from the imager.

Save to Reader Send, No Save This saves ESP settings to current memory.

Send and Save This activates all changes in current memory and saves to the imager.