The text of a manual · part 3 of 25
MS-Q Imager User's Manual, pages 21 to 30
Pages 21 to 30 of 250
The original document is the PDF (4.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-Q
Page 21
Quick Start
Bluetooth Interface Note: The USB interface draws its power from the host computer. Note: The Microscan Bluetooth modem defaults to a USB keyboard interface, and data is displayed as if input from a keyboard.
Bluetooth Configuration Item
1
2 3
Description
MS-Q Imager
USB Bluetooth Modem (Default option) USB Cable Note: RS-232 options also available
Part Number Rev 5 Hardware Rev 6 Hardware Quadrus: FIS-6100-0033G, -0034G, -0038G, -0039G, -0042G, -0043G, Quadrus: FIS-6100-0050G, -0054G -0044G, -0045G Basic: FIS-6150-0031G Basic: FIS-6150-0023G, -0024G, -0026G, -0027G 98-000076-10 Included with kit 98-000076-07, -08, -09
Installation Steps for Bluetooth 1. Connect the USB cable (3) from the host computer to the Bluetooth Modem (2). You DO NOT need to power off your host computer. 2. Open any program in the host computer that can receive and display keyboard data. 3. Read the symbol on the Bluetooth modem’s top label (2). 4. Read the Save Settings symbol at the bottom of this page. You are now ready to send data to the host.
Bluetooth Configuration
RF Two-Way Mode Note: If you are using an older Bluetooth Modem, read the RF Two-Way Mode symbol above to enable wireless communication with the host computer. Note: See Connecting to the Bluetooth Modem via RS-232 for instructions on how to use the Bluetooth Modem with a serial connection. Save Settings
MS-Q Imager User’s Manual
Default to USB
Default to PS/2
Clear All Data
Clear XML Rules
1-9
Page 22
Batch/Battery Interface
Batch/Battery Interface Important: ESP does not support Batch/Battery Interface.
Overview In Batch Mode a battery replaces the blank inside the MS-Q. The MS-Q is capable of reading more than 4,000 times from a single battery charge without being physically connected to the host. When you do connect (either by cable or wireless), the buffered data is transferred to the host in the manner determined by your batch setup.
Batch/Battery Configuration Item
Description
1
MS-Q Imager
2
Battery
Part Number Rev 5 Hardware Rev 6 Hardware Quadrus: FIS-6100-0031G, -0032G, -0036G, Quadrus: FIS-6100-0048G, -0052G -0037G Basic: FIS-6150-0029G Basic: FIS-6150-0021G, -0022G Included
Installation Steps for Batch/Battery 1. Insert the tab on the back of the battery handle into the imager’s recessed slot at the base of the battery bay. 2. Snap the imager onto the handle over the battery. Be sure that the underside of the imager is latched at the front of the handle. 3. Secure the underside of the imager to the handle with the two screws provided. 4. Select one of the Batch Setup modes - Send and Log, or Send and Buffer. 5. Read symbols as required. 6. Save settings. 7. When convenient, or when the buffer is full, open any Windows-compatible program that can accept keyboard text (for USB and PS/2) or serial data (for RS-232 and Bluetooth). 8. Attach a cable or connect to Bluetooth to download buffered data.
Batch Setup Send and Log Mode If you read the Send and Log Mode symbol to the left, all buffered data will be downloaded to the host but retained in the imager’s memory whenever you connect. Send and Buffer Mode (Default) If you read the Send and Buffer Mode symbol to the right, all buffered data will be downloaded to the host and ERASED in the imager whenever you connect. You must have a data collection program open before connecting in Send and Buffer Mode or all buffered data will be lost. Save Settings 1-10
MS-Q Imager User’s Manual
Page 23
Quick Start
Install ESP ESP Software can be found on the Microscan Tools CD that is packaged with the MS-Q. 1. Follow the prompts to install ESP from the CD. 2. Click on the ESP icon to run the program.
Note: ESP can also be installed from the Download Center at www.microscan.com.
ESP System Requirements • 166 MHz Pentium processor (recommended) • Windows Vista, XP, or 2000 operating system • Internet Explorer 5.0 or higher • 64 MB minimum RAM • 40 MB minimum disk space
Important: The imager must be in one of the modes below to communicate with ESP.
USB
USB Connect Mode
RS-232
RS-232 Connect Mode
MS-Q Imager User’s Manual
1-11
Page 24
Select Model
Select Model When you start ESP, the following menu will appear:
If you need to select another model later, click Switch Model at the top of the screen.
1. Click the MS-Q button and then click OK. If you do not want to make this selection every time you start ESP, uncheck “Show this dialog at startup”. 2. Select the default reader name (MS-Q-1), or type a name of your choice in the Description text field and click OK. 3. Click Yes when this dialog appears:
1-12
MS-Q Imager User’s Manual
Page 25
Quick Start
Select Protocol and Connect to Imager RS-232 • In the Select Protocol dialog box, select the communications protocol you are using and click Next.
• Print the RS-232 Connect Mode symbol and read it with the imager to ensure that you are in the correct communications mode. Keep the printed symbol in a convenient place for future use. • Click Next when you are finished. • The Com Port dialog will then appear. Select which communications port you are using. If you don’t see your communications port listed on the dropdown menu, select Other.
• Click Connect. • When you are connected successfully, the CONNECTED message will appear in a green box in the status bar at the bottom right of the screen.
If the connection attempt fails, enable a different communications port, check your port connections, and try again. You can also check the Force Connect box and then click the Connect button. You are now ready to configure your imager using ESP. Subsequent sections provide more detailed information about ESP’s configuration options. MS-Q Imager User’s Manual
1-13
Page 26
Select Protocol and Connect to Imager
USB • In the Select Protocol dialog box, select the communications protocol you are using and click Next.
• Print the USB Connect Mode symbol and read it with the imager to ensure that you are in the correct communications mode. Keep the printed symbol in a convenient place for future use. • Click Next when you are finished. The following dialog will then appear:
Imager ID number
• You will see a “ Reader” ID number in the Select Device field. Click Next. Note: If the imager is in the default USB Keyboard Mode when you attempt to connect, the USB Reader ID dialog will tell you to click the Switch Mode button. ESP will attempt to switch the imager to USB HID Mode. Once the imager has switched modes, click Next. • When you are connected successfully, the CONNECTED message will appear in a green box in the status bar at the bottom right of the screen.
You are now ready to configure your imager using ESP. Subsequent sections provide more detailed information about ESP’s configuration options.
1-14
MS-Q Imager User’s Manual
Page 27
2 Using ESP Contents EZ Mode ....................................................................................................................................... 2-2 Application Mode .......................................................................................................................... 2-3 Tree Controls................................................................................................................................ 2-4 Menu Toolbar ............................................................................................................................... 2-5 Send/Receive ............................................................................................................................ 2-14
This section is designed to help you understand the structure and application of ESP. When you open ESP, unless otherwise specified in the ESP Preferences dialog accessible from the Options heading on the menu toolbar, you will enter EZ Mode for initial setup. From there, you can enter Application Mode (App Mode) and access several configuration menus (Communications, Read Cycle, Symbologies, I/O Parameters, an Imager setup interface, a Terminal interface, and a Utilities interface). ESP can be used to configure the MS-Q Imager in the following ways: • Tree Controls: Each configuration menu contains a list of all option settings that pertain to that specific element of imager operation. For example, the Communications menu shows a Communications Mode command, and then the options PS/2 (AT) Keyboard, RS-232 Serial, USB Keyboard, RF (Bluetooth), and USB Native (HID), all of which are accessible from a dropdown menu. • Graphic User Interfaces: Settings can be configured using such point-and-click tools as radio buttons, tabs, spin boxes, check boxes, and drag-and-drop functions. • Terminal: ESP’s Terminal interface allows you to send configuration and utility commands directly to the imager by typing them in the provided text field.
MS-Q Imager User’s Manual
2-1
Page 28
EZ Mode
EZ Mode The EZ Mode screen is the first thing you will see when you start ESP. EZ Mode will help you get your imager up and running quickly, and will acquaint you with the ESP interface.
The EZ Mode toolbar allows you to switch to App Mode, check your connection parameters, and to switch models.
The Decode button allows you to begin capturing images and displaying decoded symbol data right away.
The Taking Pictures dropdown menu allows you to choose which trigger will activate an image capture: Handle Trigger, Right Button, or Left Button.
When an image is captured, it is displayed here as a split view that shows both the near field and far field images. Double click this image to view it in a larger format. Click Save Image to save it to a location of your choice.
2-2
MS-Q Imager User’s Manual
Page 29
Using ESP
Application Mode Application Mode gives you access to a robust configuration environment, including tree controls that let you make precise changes to operation parameters, and graphic interfaces that make configuring your imager easy and intuitive. Click here to return to EZ Mode.
Click on this icon to return to this view from Utilities or Terminal.
Menu toolbar
Click these buttons to Send and Receive commands or switch reader models.
Click here for imager button optimization, configuration, and configuration summary.
Click here to open Terminal.
Click here for Image Upload, Batch Files, and Firmware.
Click these tabs to access configuration tree controls.
Assign Preamble and Postamble characters using the simple interface shown above.
Note: For specific information on any of the icons shown above in the operations bar or configuration bar, see corresponding chapters in this manual.
MS-Q Imager User’s Manual
2-3
Page 30
Tree Controls
Tree Controls To make changes to configuration settings in the tree control menus:
1. Left click on the +/to expand or collapse the tree.
2. Double click on the parameter and click once in the selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change and click once on the setting.
4. Left click again on the open screen to complete the selection. 5. Right click on the open screen and select Save to Reader to implement the command in the imager.
The imager must be in one of the modes below to communicate with ESP.
2-4
USB
USB Connect Mode
RS-232
RS-232 Connect Mode
MS-Q Imager User’s Manual