Page 61

Communications

Bluetooth Access When the default Private Access is enabled, only one active and connected imager will be able to send data. An imager remains active if it is connected and has not reached the timeout period set in Sleep Mode Timeout. If it enters Sleep Mode, any other imager enabled for Private Access can become active and maintain exclusive access as long as it remains active itself. When Shared Access is enabled, an imager will disconnect from the host after a successful data transmission and re-connect only when it has new data to send and the host port is available. In this mode any imager can send data, but since an imager must identify itself each time it connects, a few seconds of latency will necessarily occur before each transmission. This does not prevent the imager from reading and decoding while awaiting access. All imagers must have Shared Access enabled before this mode can function in any of the imagers individually. Auto-Connect should also be enabled (otherwise, it will be necessary to read a Quick Connect Code before every re-connect and data transmission).

Private Access (Default)

Shared Access

Important: Shared Access is recommended only when RF Two-Way Mode is enabled.

Default RF

Bluetooth Access by ESP In ESP, Bluetooth Access settings are controlled by the Reader Auto-Disconnect command in the Communications tree control. When Auto-Disconnect is Disabled, the MS-Q retains a connection to the host until it enters Sleep Mode or until an explicit Disconnect command is sent (Private Access). When Auto-Disconnect is Enabled, the MS-Q will disconnect whenever there is no data to send to the host. When there is data to send, the MS-Q will connect, send the data, and disconnect once again (Shared Access).

MS-Q Imager User’s Manual

4-11

Page 62

Bluetooth Interface

Sleep Mode Timeout Following a period of inactivity, the imager will go into Sleep Mode, during which it will no longer signal its presence to the modem. It leaves Sleep Mode whenever it is powered-on or a read is attempted. When the imager leaves Sleep Mode, there will be approximately 5 seconds of connect time before a symbol can be read and transmitted. Read the symbols below to set the period of time before Bluetooth enters Sleep Mode.

90 Seconds (Default)

30 Minutes

5 Minutes

1 Hour

10 Minutes

2 Hours

15 Minutes Note: Increasing the amount of time before the imager times out will decrease battery life. Note: If the imager has power (USB cable, power cable, etc.) it will disconnect based on Cabled Timeout settings.

Default RF

Save Settings

4-12

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual

Page 63

Communications

Out-of-Range Notification This feature allows you to set the imager to beep or vibrate when the Bluetooth radio is out of range. Read the symbols below to set the desired Out-of-Range Notification profile.

Enable Out-of-Range Beep

Enable Out-of-Range Vibrate

Enable Out-of-Range Beep and Vibrate

Disable Out-of-Range Notification (Default)

Default RF

Auto-Save Last Bluetooth Address If the MS-Q is saved in the proper RF communication mode, enabling Auto-Save will allow the imager to automatically save the last device to which it was connected. This eliminates the need to Save Settings after reading the Quick Connect Code.

Disable Auto-Save (Default)

Enable Auto-Save

Default RF

Save Settings

MS-Q Imager User’s Manual

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

4-13

Page 64

Bluetooth Interface

Lockout Link Mode Lockout Link Mode can be used to establish a permanent connection between the MS-Q and a Bluetooth Modem. • Read the Quick Connect Code on the top of the modem to which you wish to establish a permanent link. • Listen for the single beep to indicate a successful connection. • Read the Lockout Link Mode symbol below. To reassign a permanent connection between the modem and a different MS-Q, read the Unlock Link symbol below. Follow the above instructions with the new imager to establish the new connection.

Unlock Link

Lockout Link Mode

Save Settings

4-14

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual

Page 65

Communications

Connecting via RS-232 with a USB Bluetooth Modem In some applications, it may become necessary to connect to a host via RS-232 using a USB Bluetooth Modem. The following steps allow you to convert a USB Bluetooth connection to RS-232. 1. Plug the USB cable into the Bluetooth Modem and the host computer’s USB port. Important: You must use a charged MS-Q battery for this procedure to work properly. 2. Read the Quick Connect Code on the top label of the Bluetooth Modem. You will now be able to decode and send data to a program in the host computer that can receive and display data. 3. Read the RS-232 Bluetooth Mode symbol and then the Save Settings symbol at the bottom of this page.

RS-232 Bluetooth Mode 4. Plug the Bluetooth Modem into an RS-232 connector and power supply. 5. Open a terminal program and connect using the following port settings: Baud = 9600 Parity = Even Stop Bits = One Data Bits = Seven Flow Control = None 6. Read the symbol below to return to USB Bluetooth Mode, and then read the Save Settings symbol at the bottom of this page.

USB Bluetooth Mode

Save Settings

MS-Q Imager User’s Manual

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

4-15

Page 66

Batch/Battery

Batch/Battery See Batch/Battery Interface on page 1-10 for instructions on installing the battery. The battery automatically charges every time a cable interface is attached to the imager and the host is powered-on. The RS-232 interface power adapter must be plugged into a wall socket for the battery to charge. In USB and PS/2 interfaces, the imager and battery draw their current from the host computer. Typical Battery Charge Times USB and PS/2 6 to 8 hours

RS-232 6 to 8 hours

Battery Charger 4 hours

Typical Battery Usage when not connected to the host: • Up to 8 hours Standby • Up to 4,000 reads Batch/Battery Communication Indicators Imager Activity Successful Decode and Data Storage Batch Memory Full

Memory LED (LEFT indicator)

Battery LEDa (RIGHT indicator)

Sound

Memory Status

None

1 beep

Solid RED

None

3 beeps a. When power is supplied via cable, the LED will remain green whenever the imager is active.

Important: When the memory LED turns RED, you must download or data will be lost.

4-16

MS-Q Imager User’s Manual

Page 67

Communications

Batch Mode Options The MS-Q Imager features three different Batch Modes for applications requiring a portable imager. Batch Modes allow a user to save data to the imager’s non-volatile memory and later transfer that data to a host computer when connected, either by USB or RS-232 cable, or by Bluetooth. The imager’s dedicated batch memory is a minimum of 1MB. The imager will automatically detect when the Bluetooth radio is out of range, or a USB or RS-232 cable is detached (provided it is plugged into a power supply). If a battery is installed, the imager will switch to Batch Mode and buffer the data in non-volatile memory. Send and Buffer Mode (Default)

Log Only Mode

Send and Log Mode

If you read the Send and Buffer Mode symbol at left, all data in the buffer will be downloaded to the host and ERASED in the imager whenever you connect. You must have a data collection program open before connecting in this mode or all buffered data will be lost. Important: Once the unit is reattached to a cable or enters within radio range, decoded data will NOT be saved to non-volatile memory. If you are using an RS-232 connection, the imager must be in Batch Mode for the data to be stored. In Log Only Mode, the imager will only store data in non-volatile memory. You can only send the data by sending the Transfer All Data command. Once the memory has been transferred to a host, all of the data will still reside in memory. You must read the Delete Data symbol to clear memory. If you read the Send and Log Mode symbol to the left, all data in the buffer will be downloaded to the host but retained in the imager’s memory whenever you connect. The data can be transferred again by reading the Transfer All Data symbol.

Reconnecting to the Host When reconnected to the host, or when the Bluetooth Radio is back in range, the imager will automatically detect the connection and, depending on the Batch Mode, transfer or log (retain) buffered data. The imager can be considered connected if: • The Bluetooth radio is in range and active. • The USB cable is attached to a host computer and the imager is enumerated. • It is in RS-232 Mode and the cable is attached to a host with power supply plugged in. • The RS-232 cable is attached to a host computer with power supply and the imager is in Batch Mode. Save Settings

MS-Q Imager User’s Manual

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

4-17

Page 68

Batch/Battery

Transferring and Deleting Data The MS-Q Imager has three different commands that can transfer data or delete data in memory. Transfer All Data

Transfer New Data

Delete Data

All data in memory is sent every time the Transfer All Data symbol is read.

Every time the Transfer New Data symbol is read, only the data in memory that hasn’t been sent will be transferred. Note: This command is not applicable in Log Only Mode. If you are in Log Only Mode, use Transfer All Data. Reading the Delete Data symbol will erase all data in the imager’s non-volatile memory.

Auto-Transfer Buffer Memory By default, when the MS-Q re-connects to the host, it will automatically transfer any data in memory. If the application on your host computer is not ready, the imager will send the data anyway, and the data could be lost. If you do not wish for the imager to send data immediately upon connection, read the Disable Auto-Transfer Buffer Memory symbol.

Enable Auto-Transfer Buffer Memory (Default)

Save Settings

4-18

Disable Auto-Transfer Buffer Memory

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual

Page 69

Communications

RS-232 Batch Features RS-232 interfaces will NOT detect when an RS-232 cable is removed unless the power supply for that cable is plugged in. If your power cable is unplugged, you still enter Batch Mode by reading the RS-232 Batch (Cable Detect) symbol below. However, when you re-connect to the RS-232 power supply you must enable RS-232 Cabled - No Power to put the imager back in Cabled mode. In RS-232 Cabled, the imager has no way to check if it is unplugged. Therefore, collected data will be automatically sent out the disconnected port (i.e., it will not buffer the data - it will only log it, assuming the imager is in Send and Log Mode.) This data would be lost if the imager were in Send and Buffer Mode.

RS-232 Batch (Cable Detect)

RS-232 Cabled - No Power

The opposite is true for RS-232 Batch (Cable Detect). In this mode, the imager assumes that it is NOT cabled. It will buffer and log the data unless you plug it into the cable that has a power supply. The imager will be able to detect the power source and will automatically switch to cabled operation. Important: When the imager is in RS-232 Cabled Mode, it will behave as if it is being attached to a cable when it is placed in the battery charger. This will cause it to download collected data, and the data will be erased from memory. To disable this feature, read the RS-232 Batch (Cable Detect) symbol.

Save Settings

MS-Q Imager User’s Manual

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

4-19

Page 70

Preamble

Preamble A preamble is a character or series of characters that is added to the beginning of a decoded data string. Preamble characters will appear in the order that they are enabled (left to right). For example, if you enable a comma and then a space, and then decode a symbol containing the data ‘ABC’, your output will look like this:

, ABC The only limit to the number of preambles enabled is the total memory size available. Important: Be sure to save all settings before reading any of the following preamble symbols - otherwise your settings may be lost.

Save Settings Set the desired preamble by reading the appropriate symbol below.

Comma

Space

Tab (USB Only)

Important: Use only with serial applications.

Tab

Erase All Preamble Data

Carriage Return Line Feed

Note: To erase all preamble and postamble data, read the following symbol:

Erase Preamble and Postamble Data

4-20

MS-Q Imager User’s Manual