The text of a manual · part 15 of 25
MS-Q Imager User's Manual, pages 141 to 150
Pages 141 to 150 of 250
The original document is the PDF (4.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-Q
Page 141
Advanced Operations
Set Decode Time The MS-Q’s default settings are designed for optimal, general purpose performance with high quality symbols on typical surfaces. For poor quality symbols, more decode time may be required. You can control the amount of time the imager spends on each decode attempt before abandoning the current attempt and beginning a new attempt. Short Decode Time
Normal Decode Time (Default) (approx. 375 mS)
Long Decode Time (approx. 675 mS)
Extra Long Decode Time (approx. 750 mS)
Save Settings
MS-Q Imager User’s Manual
Default to USB
Default to PS/2
Clear All Data
Clear XML Rules
7-21
Page 142
Button Stay-Down Time
Button Stay-Down Time Button Stay-Down Time sets the amount of time (in seconds) that the imager will continue to process the current “decode symbol” event. The imager will behave as if the trigger is being activated for this specified amount of time.
Available Button Stay-Down Time values are 0.000 to 2147483.750 (in seconds).
7-22
MS-Q Imager User’s Manual
Page 143
Advanced Operations
Mirroring Mirroring allows the MS-Q to decode symbols that are reversed. When Mirroring is enabled, all other decode functionality is disabled. Note: Once the imager has been set to Mirroring On, it can only return to its default mode by reading the Mirroring Off symbol below. Mirroring On
Mirroring Off (Default)
Note: Mirrored symbols can be read on dark or light backgrounds (depending on the current Symbol Background setting. See Symbol Background on page 7-20.)
Image Transform In ESP, the Mirroring feature is part of the Image Transform command. When Image Transform is set to Standard, Mirrored Image is disabled. When Image Transform is set to Mirrored Image, the MS-Q’s optics reverse the captured image before attempting to decode.
Save Settings
MS-Q Imager User’s Manual
Default to USB
Default to PS/2
Clear All Data
Clear XML Rules
7-23
Page 144
Motion Detection
Motion Detection Motion Detection causes the MS-Q to attempt a decode whenever it senses motion in its field of view. Motion Detection On
Motion Detection Off (Default)
Motion Detection by ESP Motion Detection settings can be refined further using the options in ESP.
Select the action you want the MS-Q to perform when it detects motion in the field of view.
Motion Sensitivity The MS-Q’s sensitivity to motion in the field of view can be configured as shown below. Note: The lower the number, the greater the sensitivity.
Save Settings
7-24
Default to USB
Default to PS/2
Clear All Data
Clear XML Rules
MS-Q Imager User’s Manual
Page 145
Advanced Operations
Auto White Balance When Auto White Balance is enabled, the MS-Q performs an automatic white balance routine, much like a digital camera. Light and dark values are optimized to improve decode performance.
MS-Q Imager User’s Manual
7-25
Page 146
Symbol Readability Index
Symbol Readability Index The Symbol Readability Index provides a measurement of a specific symbol’s readability. It is specific to the MS-Q Imager and should not be confused with a verification quality measurement. The Symbol Readability Index is a blend of information obtained from the internal operations of the decoding algorithm relating to contrast, symbology construct, error detection, forward error correction (if applicable), and other symbology-specific characteristics. The Index is a score on a scale of 1 (very poor) to 100 (very readable). Due to the effects of motion, skew, reflection, focus, and ambient light, the Readability Index on the same symbol may vary somewhat from read to read. However, a poor contrast or damaged symbol will score lower than a high contrast undamaged symbol. The Index can be used as a quick check on the reliability of label generation or marking systems. When used in conjunction with a stand and constant ambient light, the Index provides a symbol quality assurance tool and check-point for feedback to an overall symbol or marking quality control system. The Symbol Readability Index is enabled by reading an XML rule into imager memory. Enable Symbol Readability Index
The imager will store this XML rule and reset, but will not output a Readability Index value until the Enable Readability Index Output symbol is read. When output is enabled, a Symbol Readability Index value will be added to all decoded data output. Example: 100 (symbol readability),1234567890 (symbol data) The imager will output the Symbol Readability Index for every decode until the feature is disabled. Enable Readability Index Output
Save Settings
7-26
Default to USB
Disable Readability Index Output
Default to PS/2
Clear All Data
Clear XML Rules
MS-Q Imager User’s Manual
Page 147
8 Terminal Contents Terminal View................................................................................................................................8-2 Find ...............................................................................................................................................8-3 Send ..............................................................................................................................................8-4 Macros...........................................................................................................................................8-5 Terminal Right-Click Menu ............................................................................................................8-6 Terminal Dropdown Menu .............................................................................................................8-7
This section describes the Terminal interface and macro functions in ESP.
MS-Q Imager User’s Manual
8-1
Page 148
Terminal View
Terminal View Click the Terminal button.
You will see the following view: Clear screen, copy, paste, save.
Type text here to find matching text in the terminal window.
Terminal screen
Macros listed on this bar. Click on Macros arrow to Add Macro, Remove Macro, or Edit Macro.
Type text commands here.
Click on desired macro to run.
The Terminal interface allows you to send commands to the imager by using macros, by copying and pasting, or by typing commands in the Send text field. The Terminal view also displays symbol data or information from the imager. You can also right click on the Terminal screen to bring up a menu of further options.
8-2
MS-Q Imager User’s Manual
Page 149
Terminal
Find The Find function allows you to enter text strings to be searched for in the terminal window. For example, suppose a series of symbols have been scanned into the terminal view and you want to determine if a particular symbol whose data begins with “ABC” has been read. 1. Type “ABC” into the Find box.
2. Press Enter. The first instance of “ABC” will be highlighted in the terminal window. 3. Click the Find button to the left of the text field to locate additional instances of “ABC”.
MS-Q Imager User’s Manual
8-3
Page 150
Send
Send The Send function allows you to enter text commands and then send them to the imager. (See Text Commands on page 4-24.) For example, suppose you want to enable the imager’s laser target. To enable the target using a text command, you would enter “P%0f3” (the command string that activates the laser target) in the text field and click Send.
Click here to access the dropdown menu of stored text commands.
Type text commands in the text field and then click the Send button to initiate. Clicking Send repeatedly will initiate the command repeatedly.
Once text commands are initiated, they are saved in a dropdown menu that can be accessed by clicking the arrow to the right of the text field. You can also send the current command repeatedly by clicking the Send button repeatedly.
8-4
MS-Q Imager User’s Manual