Page 131
Advanced Operations
Right Button Optimization Important: VGA “Fast Processing” is only supported in Rev 5 hardware and earlier. High and Low Density Symbols
High Density Symbols Low Density Symbols
Near and Far Field
Near Field
Far Field
A1
B1
C1
D1
A2
B2
C2
D2
B3
C3
D3
Region of Interest
A3
Fast Processing (VGA Mode)
Right Button Programming Both Fields (Default)
Near Field Only
Far Field Only
Right Button Take Picture
Disable Right Button
MS-Q Imager User’s Manual
7-11
Page 132
Trigger Optimization
Continuous Trigger Optimization Important: VGA “Fast Processing” is only supported in Rev 5 hardware and earlier. High and Low Density Symbols
High Density Symbols Low Density Symbols
Near and Far Field
Near Field
Far Field
A1
B1
C1
D1
A2
B2
C2
D2
B3
C3
D3
Region of Interest
A3
Fast Processing (VGA Mode)
Continuous Trigger Programming Both Fields
Near Field Only
Far Field Only
Disable Continuous Trigger (Default)
Save Settings
7-12
Default to USB
Default to PS/2
Clear All Data
Clear XML Rules
MS-Q Imager User’s Manual
Page 133
Advanced Operations
Optimization Parameters The following 12 settings (A1 through D3) allow you to optimize the imager’s performance in your particular application environment. Try several settings to familiarize yourself with the differences between the 12 options. Use A1 if you are reading a variety of symbol sizes and densities, and you are more concerned with decode capability than with decode speed. Use A2 if you are reading a variety of symbol sizes and densities, and you require dependable but moderately fast decodes.
Use A3 if you are reading a variety of symbol sizes and densities, but you are concerned mainly with obtaining fast decodes.
Use B1 if you are reading a variety of symbol sizes and densities, and you need reliable, moderately fast decodes.
Use B2 if you are reading a variety of symbol sizes and densities, and you want a balance of decode reliability and decode speed. Use B3 if you are reading a variety of symbol sizes and densities, but you want the fastest decode speed available.
High and Low Density Symbols Near and Far Field A1: Reads high and low density symbols at high resolution in near and far fields; spends 675 mS attempting to decode the symbol; large region of interest that extends beyond the symbol.
B1: Reads high and low density symbols in near and far fields at high resolution in both fields; spends 375 mS attempting to decode the symbol; large region of interest that extends beyond the symbol.
A2: Reads high and low density symbols in near and far fields at medium-high resolution in near field and high resolution in far field; spends 375 mS attempting to decode the symbol; region of interest that extends somewhat beyond the symbol.
B2: Reads high and low density symbols in near and far fields at medium-low resolution in near field and medium-high resolution in far field; spends 250 mS attempting to decode the symbol; region of interest that extends somewhat beyond the symbol.
A3: Reads high and low density symbols at low resolution in near field and medium-low resolution in far field; spends 250 mS attempting to decode the symbol; region of interest limited to the symbol and its quiet zone.
B3: Reads high and low density symbols in near and far fields at low resolution in both fields; spends 250 mS attempting to decode the symbol; small region of interest limited to the symbol and its quiet zone. (Rev 5 hardware and earlier only.)
Note: See the Optimization Guide for definitions of optimization terminology (page 7-7).
MS-Q Imager User’s Manual
7-13
Page 134
Trigger Optimization
Optimization Parameters (cont.) High Density Symbols Low Density Symbols Near Field
Far Field
C1: Reads high density symbols only at high resolution in near field only; spends 375 mS attempting to decode the symbol; large region of interest that extends beyond the symbol.
D1: Reads low density symbols only at high resolution in far field only; spends 375 mS attempting to decode the symbol; large region of interest that extends beyond the symbol.
C2: Reads high density symbols only at medium-low resolution in near field only; spends 375 mS attempting to decode the symbol; region of interest that extends somewhat beyond the symbol.
D2: Reads low density symbols only at medium resolution in far field only; spends 375 mS attempting to decode the symbol; region of interest that extends somewhat beyond the symbol.
Use C1 if you are reading small or medium high density symbols and you need reliable and moderately fast decodes. Use C2 if you are reading small or medium high density symbols and you are more concerned with decode speed than decode reliability. Use C3 if you are reading small or medium high density symbols and you are most concerned with obtaining fast decodes. Use D1 if you are reading medium or large low density symbols and you want reliable and moderately fast decodes.
Use D2 if you are reading medium or large low density symbols and you want a balance of decode reliability and speed. C3: Reads high density symbols only, at low resolution in near field only; spends 250 mS attempting to decode the symbol; small region of interest limited to the symbol and its quiet zone. (Rev 5 hardware and earlier only.)
D3: Reads low density symbols only at low resolution in far field only; spends 250 mS attempting to decode the symbol; small region of interest limited to the symbol and its quiet zone. (Rev 5 hardware and earlier only.)
Use D3 if you are reading medium or large low density symbols and you are more concerned with fast decodes than reliability.
Note: See the Optimization Guide for definitions of optimization terminology (page 7-7).
7-14
MS-Q Imager User’s Manual
Page 135
Advanced Operations
Trigger Optimization by ESP You can use ESP’s Imager view to set operation parameters for the handle trigger and both buttons.
Single click the Imager button to begin.
ESP Optimization Matrix Choose which trigger or button to optimize from this dropdown menu.
Each button corresponds with a setting on the Optimization Guide matrix (page 7-7).
Note: VGA Fast Processing settings B3, C3, and D3 are shown here when a Rev 5 (or earlier) MS-Q model is connected. VGA settings are not supported in Rev 6 MS-Q models.
The Configuration Status display shows current settings for each trigger or button.
MS-Q Imager User’s Manual
7-15
Page 136
Trigger Optimization by ESP
Trigger/Button Configuration In the Trigger/Button Configuration view you can set the same optimization parameters from a list, and you can also set additional parameters.
Choose which trigger or button to optimize from this dropdown menu.
Each trigger optimization option corresponds with a setting on the Optimization Guide (page 7-7).
The Configuration Status display shows current settings for each trigger or button.
7-16
MS-Q Imager User’s Manual
Page 137
Advanced Operations
Trigger/Button Summary The Trigger/Button Summary view has the same Configuration Status information as the other two views, but it supplements that information with a diagram of the MS-Q Imager.
This graphic interface orients the user to the location of the imager’s handle trigger and the left and right top buttons.
Configuration Status shows current settings for each trigger or button.
MS-Q Imager User’s Manual
7-17
Page 138
Continuous Operations
Continuous Operations Continuous Read Read any of the following symbols to enable or disable Continuous Read features. Note: Continuous Read modes are only recommended for short term use because of battery consumption. See Sleep Mode Timeout on page 4-12.
Near and Far Field
Near Field Only
Far Field Only
Continuous Read Off (Default)
Continuous Read, Sleep Timeout Cabled Read one of the symbols below to set the amount of time the cabled imager will operate in Continuous Read before entering Sleep Mode.
Cabled - 2 Hours
Cabled - Always On (Default)
Uncabled Read one of the symbols below to set the amount of time the uncabled imager will operate in Continuous Read before entering Sleep Mode.
Uncabled - 5 Minutes (Default)
Uncabled - 15 Minutes
Uncabled - 30 Minutes
7-18
MS-Q Imager User’s Manual
Page 139
Advanced Operations
Continuous Read, Trigger Delays Read the following symbols to set the delay time between decodes.
0 Seconds (Default)
1 Second
3 Seconds
Continuous Read, Duplicate Read Delays
0 Seconds (Default)
1 Second
3 Seconds
Continuous Read Off (Default)
Save Settings
MS-Q Imager User’s Manual
Default to USB
Default to PS/2
Clear All Data
Clear XML Rules
7-19
Page 140
Symbol Background
Symbol Background “Symbol Background” refers to the color of the substrate on which a symbol is printed or marked. In the default state, Reverse Background On means that both types of symbols, dark-on-light and light-on-dark, will be read. Reverse Background Off will speed up image processing if only dark symbols on light backgrounds are being read.
Reverse Background On (Default)
Reverse Background Off
Sample Data Matrix Symbol (Light Background)
Sample Data Matrix Symbol (Dark Background)
Save Settings
7-20
Default to USB
Default to PS/2
Clear All Data
Clear XML Rules
MS-Q Imager User’s Manual