Page 151

Terminal

Macros Macros can be stored in a macro selection bar, edited in a separate window, and executed by clicking on the macro name.

When you click Move to Start, the names of all the macros appear, as shown at left. Choose which macro button you want to appear in the first position at the bottom of the terminal view.

Click on all subsequent arrows to Edit the associated macros.

Click on Next Row to see the next set of macro buttons.

Click on the first arrow here to see Add Macro, Default Macros, and Move to Start. When you default macros, the entire macros set is restored to original commands.

Clicking on a macro button executes the related command. The command is also sent to the imager at the same time it is displayed.

Editing a Macro When you click the arrow next to a any macro and select Edit, the following dialog appears:

You can edit an existing macro or type in the Macro Name text field and define it in the Macro Value text field. MS-Q Imager User’s Manual

8-5

Page 152

Terminal Right-Click Menu

Terminal Right-Click Menu Right click in the terminal window to display the following menu: • Copy selected text to clipboard. • Paste from terminal or other text. • Clear all text in terminal window. • Select All text in the terminal window. • Save... incoming and outgoing data into a text file. • Change Font... of data received from the imager. • Change Echo Font... to change the appearance of user-entered data. • Disable Echo to hide user-entered data. • Change Background Color of the terminal window. • Non-Printable Characters can be shown or hidden in the terminal view in Standard or Enhanced format. • Default Settings to return all of the above to original settings. • Keyboard Macros brings up the Function Keys dialog, which allows you to create customized macro functions.

Function Keys The Function Keys dialog allows you to assign commands to specific function keys on a standard keyboard. Note that the F1 key is reserved for opening ESP Help, and the F3 key is reserved for the Find Next function.

Select the desired function key and then enter your macro keystrokes in the associated key map. For example, to make Ctrl-F2 the keystroke to send a trigger character, select F2, then in the Ctrl text field, enter <trigger character> and click OK. Then whenever Ctrl-F2 is keyed, the trigger character will start the read cycle.

Note: This feature is also available from the Terminal Dropdown Menu and the Terminal tab of the Preferences dialog.

8-6

MS-Q Imager User’s Manual

Page 153

Terminal

Terminal Dropdown Menu The terminal dropdown menu allows you to capture and save current text, and it also includes the functions defined for the Terminal Right-Click Menu. • Capture Text... lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened. You can select Pause to interrupt the capture flow or Stop to end the flow and open the file. • Save Current Text... saves all text in the terminal window to a text file of your choice. • Find Next locates the next instance of the specified data string in the terminal. This function can also be activated by pressing F3. • Find Previous locates the most recently occurring instance of the specified data string in the terminal. • Keyboard Macros brings up the Function Keys dialog, which allows you to create customized macro functions.

MS-Q Imager User’s Manual

8-7

Page 154

Terminal Dropdown Menu

8-8

MS-Q Imager User’s Manual

Page 155

9 Utilities Contents Image Upload................................................................................................................................9-2 Device Control...............................................................................................................................9-3 Differences from Default ...............................................................................................................9-4 Firmware .......................................................................................................................................9-5 Bluetooth .......................................................................................................................................9-7 Advanced ......................................................................................................................................9-8

This chapter explains ESP’s Utilities features. These include Image Upload, which allows you to capture images using the MS-Q; Device Control, an interface that lets you perform major operations with one click; Differences from Default, which shows all currently enabled MS-Q settings that are not default settings; Firmware, where you can update your imager’s firmware; Bluetooth, which can produce a “Quick Connect” symbol from alphanumeric text input; and Advanced, which allows you to collect batch files for customized imager configuration and optimization.

MS-Q Imager User’s Manual

9-1

Page 156

Image Upload

Image Upload ESP’s Image Upload feature allows you to collect and save image captures. Choose desired JPEG image resolution, or select Bitmap (BMP) format.

Select your depth of field and field of view (SXGA-1280 x 1024) (VGA available for Rev 5 hardware or earlier).

Select the trigger you want to use to capture the image, then click the Start button to begin the image capture process.

Image captures are displayed in the Far Field and Near Field windows, depending on which field is enabled (Far, Near, or Both).

9-2

MS-Q Imager User’s Manual

Page 157

Utilities

Device Control This feature allows you to clear data stored in the imager’s memory, to default the imager, to deactivate or clear XML rules, to upload or delete stored errors, to reboot the imager, and to delete stored results.

• Clear All Data removes decoded symbol data and commands in the imager’s memory. • Default Reader returns the imager to its default state, without any optimization or configuration. • Deactivate XML Rules turns off, but does not erase, preambles, postambles, and XML commands. • Clear XML Rules removes preambles, postambles, and other XML commands. • Upload Logged Errors allows you to look at stored error reports. • Delete Stored Errors erases all logged errors whether you have looked at them or not. • Reboot Reader refreshes the imager’s memory and functionality, returning it to the most recent configuration you have saved. • Delete Stored Results erases logged data.

MS-Q Imager User’s Manual

9-3

Page 158

Differences from Default

Differences from Default Clicking the Differences from Default button will cause ESP to check all stored configuration settings and compare them to default settings. All settings that are different from default will appear in the left column (shown below), and descriptions of those settings will appear in the right column. Click this button for a list of ESP configuration settings that are different from default settings.

Click Generate Barcode to bring up the Bar Code Configuration dialog. Then create symbols containing the configuration commands of your choice.

Send configuration settings to the reader without saving by clicking Send to Reader.

Click Save As to save the report as plain text or a tab-delimited text file.

Send configuration settings to the reader and save in ESP by clicking Send and Save.

• To create a symbol containing any of the command settings in the table, click Generate Barcode. This will bring up the Bar Code Configuration dialog. • To save the Differences from Default report, either as plain text or as a tab-delimited text file, click Save As. • Click Send and Save to send the settings to the reader and save them, or Send to Reader to send the settings without saving them.

9-4

MS-Q Imager User’s Manual

Page 159

Utilities

Firmware The Firmware view in ESP Utilities is a simple way to update and verify your imager’s firmware and to update batch files. Choose App Code from the Firmware Update dropdown menu and click Start to install new firmware in the MS-Q.

Use this dropdown menu to locate batch files in the host computer’s file directory. Download the needed files directly to the imager by clicking the Start button.

MS-Q Imager User’s Manual

The Firmware Verification tool sends a direct query to the imager for its Application Code Version, Firmware Version, Boot Code Version, and Radio Version.

9-5

Page 160

Firmware

Imager ID Another way to query the imager for its identifying information is by reading the following symbol:

Imager ID

The host’s text program will output a data string containing the imager’s identifying information in the following format: Internal ID

Boot code version

App code (software part number)

Serial number

Xap/i2300230006000010006664A0235-616001-16

Firmware version

Save Settings

9-6

Radio version (Bluetooth)

Default to USB

“A” indicates that running firmware is the application. “B” if bootloader. “02” is an internal ID.

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual