For the Microscan MS-890

Page 21

Quick Start

Step 7, Receive Settings To copy the scanner’s memory settings into ESP, right-click in the configuration window and select Receive Reader Settings from the dropdown menu.

Receive Reader Settings

When you select Receive Reader Settings, the settings from the scanner’s memory are sent to ESP.

MS-890 Industrial Automation Scanner User’s Manual

1-9

Page 22

Calibrate

Step 8, Calibrate 1. Click the Calibration button in EZ Mode or in the Calibration view.

2. Allow some time for the scanner to cycle through the focus, gain, and tracking settings. Do not move or disturb the scanner or test symbol while calibration is in progress. 3. When calibration is complete, the settings that provided the highest read rate will be selected. You will see one of the following messages: Calibration Passed, Calibration Failed, or Original Settings Were Optimal. Note: To silence the beeper, interrupt scanning by removing or blocking the test symbol, or send a <K702,0> command to disable the beeper.

If calibration fails, try the following: 1. Check the read range for your particular symbol density. 2. Examine symbol quality and try a different sample symbol. 3. Slightly skew or tilt the symbol or scanner to minimize specular reflection. 4. Verify that the correct symbology is enabled.

1-10

MS-890 Industrial Automation Scanner User’s Manual

Page 23

Quick Start

Step 9, Test Read Rate Important: To receive symbol data through the 9-pin configuration port, you must enable the port with the following command: <K146,,1>. 1. Position the symbol in front of an operational MS-890 scanner. 2. Click the Utilities button. 3. Click the Start button in the Read Rate view.

If calibration has passed, the scanner sends data to the host computer and emits a beep (if the beeper is enabled) for each good read. Move your symbol toward the scanner and away from the scanner until the decode rates drop off in each direction. This will give you a sense of the depth of field (inner and outer ranges) for your symbol’s density and range.

De p th f i e of ld

Note: If the scanner is in the default Continuous Read mode and not in read rate or calibration routine, it will read and beep repeatedly as long as a readable symbol remains in the read range and the read cycle configuration has not changed. • To end the read rate test, right click Read Rate and select the Stop button.

MS-890 Industrial Automation Scanner User’s Manual

1-11

Page 24

Configure the Scanner in ESP

Step 10, Configure the Scanner in ESP To make setup changes to the MS-890, click the App Mode button.

The following modes are accessible by clicking the buttons in the first row of App Mode icons: • Test and Calibrate the scanner in EZ Mode. • Establish communications between ESP and the scanner by clicking the Autoconnect button. • Send or receive commands by clicking the Send/Recv button. • Switch reader models by clicking the Switch Model button. • Click the Parameters button to make changes to tree control settings. • Click the Setup button to adjust and test scanner settings in Calibration, Raster Setup, Laser Framing, Configuration Database, Ordered Output, and Output Format. • Access the Terminal, where you can view symbol data and enter serial commands. • Review status settings or make changes to operational commands in Utilities.

1-12

MS-890 Industrial Automation Scanner User’s Manual

Page 25

Quick Start

Step 11, Save Configuration in ESP To make changes to a configuration setting: 1. Left click on the + to expand the desired tree. 2. Double click on the desired parameter and click once in the selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change, and click once on the setting.

4. Left click again on the open screen to complete your selection.

5. Right click on the open screen and select Save to Reader to implement the command in the scanner.

Saving Options • Send, No Save. Changes will be lost when power is re-applied to the scanner. • Send and Save. This activates all changes in current memory and saves to the scanner for power-on.

MS-890 Industrial Automation Scanner User’s Manual

1-13

Page 26

Save Configuration in ESP

1-14

MS-890 Industrial Automation Scanner User’s Manual

Page 27

2 Using ESP Contents EZ Mode........................................................................................................................................2-2 Application Mode...........................................................................................................................2-3 Menu Toolbar ................................................................................................................................2-4 Autoconnect ................................................................................................................................2-12 View ............................................................................................................................................2-14 Navigating in ESP .......................................................................................................................2-15 Send/Receive Options ................................................................................................................2-16

This section is designed to help you understand the basic structure and elements of ESP (Easy Setup Program). When you open ESP, unless otherwise specified in the ESP Preferences dialog accessible from the Options heading on the menu toolbar, you will enter EZ Mode for initial setup. From there, you can enter Application Mode (App Mode) and access several configuration menus (Communications, Read Cycle, Symbologies, I/O Parameters, Symbol Quality, Matchcode, and Diagnostics), a Camera setup interface, a Terminal interface, a Utilities interface, and an Output Format interface. For ESP system requirements, see System Requirements for ESP in Chapter 1, Quick Start. Important: If you are switching from an MS-880 to an MS-890 in your application, follow these steps when you open ESP: • With your MS-890 connected to the host computer, open your most recent MS-880 .esp file. • Connect to the MS-890 and send all settings. • Click the Switch Model button at the top of the ESP view. When you see the model menu, select the MS-890. • Receive settings. Note: After receiving settings, you can delete the previous MS-880 model by opening the Model dropdown menu from the menu toolbar, selecting Remove Model, and selecting MS-880.

MS-890 Industrial Automation Scanner User’s Manual

2-1

Page 28

EZ Mode

EZ Mode In EZ Mode you are presented with the Locate, Calibrate, and Test options. After connecting to your scanner, EZ Mode is the screen you will see. You will be provided with on-screen instructions that will help you with positioning, testing, and calibration.

Test Click the Test button to start the Read Rate test for a quick indication of the scanner’s read capabilities and the limits of your application. When Decodes per Second is unchecked, the test will count the percentage of decodes relative to the number of actual scans. Click Stop to end the test.

Calibrate The calibration routine that will optimize the scanner by comparing Read Rates at various camera and image processing settings.

Starts Read Rate test.

Click Calibrate to begin the initial calibration routine. Calbration is explained at the left of the EZ Mode screen, and also in Quick Start.

Enter App Mode to access configuration trees and other setup features.

Saves Calibration settings. Allows you to decode a variety of symbologies without stopping your application to reconfigure symbology settings.

Ends Read Rate test.

2-2

MS-890 Industrial Automation Scanner User’s Manual

Page 29

Using ESP

Application Mode From EZ Mode, you can click on the App Mode button to access specific configuration menus, Utilities tools, Camera setup, Output Format options, and a Terminal window where serial commands can be entered.

Note: The App Mode and EZ Mode buttons appear in the same position to allow easy switching between these primary modes. Click this icon to return to EZ Mode.

Menu toolbar.

Calibration, Raster/Laser, Terminal, Utilities.

Click here for Ordered Output and Output Format features.

Click on icons in this row to access configuration trees like the one shown here.

Click the Configuration button to return to full App Mode view from Calibration, Raster/Laser, Terminal, Utilities, or Output Format.

Note: For specific information on any of the icons shown above in the operations bar or configuration bar, see the corresponding sections of this manual.

MS-890 Industrial Automation Scanner User’s Manual

2-3

Page 30

Menu Toolbar

Menu Toolbar File > New Whenever New is selected, the default configuration of ESP is loaded.

Open/Save When Save or Save As is selected, the ESP configuration is saved to the host computer’s hard drive and available whenever the same file is selected under Open. Important: When you save menu changes to your hard drive, these changes are not saved to your scanner. The illustration below shows how settings can be saved and received between ESP and the scanner, and ESP and the host hard drive.

(Save to Scanner) (Receive Scanner Settings)

Import/Export Import converts the ASCII settings from a text file to ESP configuration settings. Export converts the active ESP configuration settings to an ASCII text file.

2-4

MS-890 Industrial Automation Scanner User’s Manual