The text of a manual · part 4 of 31
MS-890 Industrial Automation Scanner User's Manual, pages 31 to 40
Pages 31 to 40 of 308
The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-890
Page 31
Using ESP
Model In Model you can select any of the models shown in ESP’s model menu. When you choose another model, your current connection to your present model will be terminated. To connect to another model, select New Model, choose a new model from the menu, and click OK.
Note: All the models you have enabled by selecting will continue to appear in the Model menu and that the same menu is repeated when clicking the Switch Model icon.
When you save your ESP file, you will be saving the settings of all the models defined in a single ESP file.
MS-890 Industrial Automation Scanner User’s Manual
2-5
Page 32
Menu Toolbar
Options The Options menu allows you to save memos and set up ESP Preferences. Note: Preferences will be saved and loaded into ESP whenever ESP is opened next, whether or not you save the ESP file.
Preferences > General Tab
The Toolbar Style options allow you to determine how ESP will display the mode options in the two rows at the top of the screen.
Reload Last File At startup, reloads the last file saved to the host computer’s hard drive.
Show Model Prompt At startup, shows the model menu displaying all supported readers.
Show Connect Prompt At startup, displays the Would you like to connect to the MS-890? prompt.
Receive After Connect At startup, loads the scanner’s settings into ESP. (This is not recommended if you want to preserve your ESP settings for future use.)
Skip EZ Mode At startup, skips EZ Mode and opens directly in App Mode.
Enable ‘Send and Save as Customer Defaults’ At startup, enables the Send and Save as Customer Defaults option in the Send/Recv command. 2-6
MS-890 Industrial Automation Scanner User’s Manual
Page 33
Using ESP
Preferences > Terminal Tab
Show Non-Printable Characters When Show Non-Printable Characters is enabled, characters such as “CRLF” will be displayed in the Terminal window. When Enhanced Format is checked, the characters are displayed with more detailed formatting.
Change Keyboard Macros Clicking the Change Keyboard Macros button brings up the Function Keys dialog. In this dialog you can select the desired function key and then enter your macro keystrokes in the associated key map. For example, to make Ctrl-F2 the keystroke to send a trigger character, select F2, then in the Ctrl row, enter <trigger character> and click OK. Then whenever the Ctrl-F2 keystroke is pressed, the trigger character will start the read cycle. Note: The F1 key is reserved for opening ESP Help and the F3 key is reserved for the Find Next function.
Change Font Allows you to modify the font used for decode data received from the scanner on the Terminal screen.
Change Echo Font Allows you to modify the font used for command characters typed into the Terminal view.
Enable Echo Allows you to enter command characters in Terminal.
Display Incoming Data Even When Not in Focus When Display Incoming Data Even When Not in Focus is enabled, data from the scanner will continue to appear in the terminal even when ESP is not the top window. MS-890 Industrial Automation Scanner User’s Manual
2-7
Page 34
Menu Toolbar
Preferences > Bar Code Options Tab
The Bar Code Options dialog allows you to set the size of user-created symbols.
Sizing Information Sets the bar width or module width (in mils, or thousandths of an inch) of user-created symbols. Example: A bar width of 13 is 0.013 inches.
Caption Allows you to choose the font of human-readable captions (if symbol captions are required), and to determine the orientation of captions in relation to symbols. Note: Symbols can be created using the Bar Code Dialog.
2-8
MS-890 Industrial Automation Scanner User’s Manual
Page 35
Using ESP
Preferences > Advanced Tab
The Auto Sync options at the top of the Advanced tab allow you to determine whether Auto Sync will be enabled automatically in sections of ESP where it is used, or if it will ask you before it enables Auto Sync functions.
Always Ask Before Auto Sync Occurs If you check this option box, you are then able to determine what specific Auto Sync functions will be enabled. Receive Settings from the Reader will automatically send the scanner’s settings to ESP when Auto Sync is enabled. Send ESP Settings to the Reader will automatically send all scanner configuration settings chosen in ESP to the scanner. Do Not Send or Receive Settings creates a condition in which Auto Sync will not automatically send scanner settings to ESP, or send ESP settings to the scanner.
Send XON with Autoconnect Sends an XON (Begin Transmission) command to the scanner before starting the Autoconnect routine.
Ask to Save ESP File when Quitting When enabled, prompts the user to save a .esp file when ending a session.
The .esp file will be saved in the location of your choice.
MS-890 Industrial Automation Scanner User’s Manual
2-9
Page 36
Menu Toolbar
Preferences > Advanced Tab (cont.)
Show TCP/IP Connection Option When enabled, shows a TCP/IP option on the Select Protocol dialog. Note: This option should only be selected if you intend to connect using an Ethernet adapter.
Use Default Storage Location When enabled, automatically stores data in ESP’s Application Data folder.
2-10
MS-890 Industrial Automation Scanner User’s Manual
Page 37
Using ESP
Document Memo The information you type in the Document Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Document Memo item on the Options menu.
Model Memo Similar to Document Memo, the information you type in the Model Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Model Memo item on the Options menu. Memos created in Model Memo are specific to the model enabled when the message was created.
Note: Memos must be saved in a .esp file if you want them to available in your next session. If you do not save your current session, any memos that you have entered during the session will be discarded, and will be unavailable in your next session.
MS-890 Industrial Automation Scanner User’s Manual
2-11
Page 38
Autoconnect
Autoconnect • You can use Autoconnect to establish a connection between the scanner and the host.
• If your communications port is not the default COM1, use the dropdown menu to change ports.
• Once you have chosen the correct port, click Start to connect.
When you are connected, you will see the green connection indicator in the status bar at the bottom right of your screen:
2-12
MS-890 Industrial Automation Scanner User’s Manual
Page 39
Using ESP
Autoconnect (cont.) If your RS-232 host settings cannot be changed to match the scanner’s settings: • Click Connect on ESP’s menu toolbar, and then select Connection Wizard. • When the Select Protocol dialog appears, select RS-232 and click Next.
• When the RS-232 dialog appears, check the Force Connect box and click the Connect button.
MS-890 Industrial Automation Scanner User’s Manual
2-13
Page 40
View
View The View menu allows you to move quickly between interfaces without using the icon buttons on the App Mode toolbar. It also allows you to access the Bar Code Dialog.
Bar Code Dialog In the Bar Code Dialog you can create symbols by typing the text you wish to encode. This is a useful tool for creating configuration symbols, allowing you to configure your scanner by reading the symbols you create.
Drag configuration commands from the tree controls directly into this field to encode new symbols. Choose a spatial orientation for the new symbol. Create a caption for the symbol that matches the encoded data, or write your own caption.
The symbols you create will be displayed in the field at the bottom of the Bar Code Dialog.
Click the Differences from Default Settings button to create a symbol encoded with configuration settings that differ from ESP defaults. Differences from Default can be viewed on the Differences tab in the Utilities view. Click Add start configuration code and Add end configuration code; Save Settings to add a symbol that will enable Bar Code Configuration mode and a symbol that will save all new configuration settings. (Both symbols shown at left).
See Bar Code Configuration on page A-23 for more information about configuring the MS-890 by decoding symbols.
2-14
MS-890 Industrial Automation Scanner User’s Manual