Page 11

Introduction

Statement of RoHS Compliance All Microscan readers with a ‘G’ suffix in the FIS number are RoHS-Compliant. All compliant readers were converted prior to March 1, 2007. All standard accessories in the Microscan Product Pricing Catalog are RoHS-Compliant except 20-500013-01 and 98-000039-02. These products meet all the requirements of the European Parliament and the Council of the European Union for RoHS compliance. In accordance with the latest requirements, our RoHS-compliant products and packaging do not contain intentionally added Deca-BDE, Perfluorooctanes (PFOS) or Perfluorooctanoic Acid (PFOA) compounds above the maximum trace levels. To view the documents stating these requirements, please visit: http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=CELEX:32002L0095:EN:HTML and http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2006:372:0032:0034:EN:PDF

Please contact your sales manager for a complete list of Microscan’s RoHS-Compliant products. This declaration is based upon information obtained from sources which Microscan believes to be reliable, and from random sample testing; however, the information is provided without any representation of warranty, expressed or implied, regarding accuracy or correctness. Microscan does not specifically run any analysis on our raw materials or end product to measure for these substances. The information provided in this certification notice is correct to the best of Microscan’s knowledge at the date of publication. This notice is not to be considered a warranty or quality specification. Users are responsible for determining the applicability of any RoHS legislation or regulations based on their individual use of the product.

MS-890 Industrial Automation Scanner User’s Manual xi

Page 12

Statement of RoHS Compliance xii

MS-890 Industrial Automation Scanner User’s Manual

Page 13

1 Quick Start Contents Step 1 Check Required Hardware................................................................................................ 1-2 Step 2 Connect the System.......................................................................................................... 1-3 Step 3 Position Scanner and Symbol ........................................................................................... 1-5 Step 4 Install ESP......................................................................................................................... 1-6 Step 5 Select Model ..................................................................................................................... 1-7 Step 6 Autoconnect ...................................................................................................................... 1-8 Step 7 Receive Settings ............................................................................................................... 1-9 Step 8 Calibrate.......................................................................................................................... 1-10 Step 9 Test Read Rate ............................................................................................................... 1-11 Step 10 Configure the Scanner in ESP ...................................................................................... 1-12 Step 11 Save Configuration in ESP............................................................................................ 1-13

This chapter is designed to get your MS-890 up and running quickly, using the EZ Button or ESP (Easy Setup Program). Following these steps will allow you to get a sense of the scanner’s capabilities and to test symbol decode performance. Detailed setup information for installing the scanner into your application can be found in the subsequent chapters. Important: If you are switching from an MS-880 to an MS-890 in your application, follow these steps when you open ESP: 1. With your MS-890 connected to the host computer, open your most recent MS-880 .esp file. 2. Connect to the MS-890 and send all settings. 3. Click the Switch Model button at the top of the ESP view. When you see the model menu, select the MS-890. 4. Receive settings. Note: After receiving settings, you can delete the previous MS-880 model by opening the Model dropdown menu from the menu toolbar, selecting Remove Model, and selecting MS-880.

MS-890 Industrial Automation Scanner User’s Manual

1-1

Page 14

Check Required Hardware

Step 1, Check Required Hardware

Hardware Required Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.

Item 1 2 3 4 5

Description MS-890 Industrial Automation Scanner 9-Pin Configuration Cable Power Supply Object Detector (optional) Comm./Serial Cable

Part Number FIS-0890-0001G, -0002G 61-000010-02 97-100004-15 99-000004-01 61-000034-02

Note: Standalone configuration shown above.

1-2

MS-890 Industrial Automation Scanner User’s Manual

Page 15

Quick Start

Step 2, Connect the System

With Wiring Box

Standalone

Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.

Connecting the MS-890 Standalone 1. Attach the configuration cable to either the 9-pin (preferred) or 25-pin connector (on bottom of unit) to configure, test, and default the scanner.

2 Receive 3 Transmit 5 Signal ground 9-pin host configuration connector

2. Attach the power supply cable to the 3-pin power connector on the bottom of the scanner.

Chassis ground 2

3 Power +10 to 28 VDC (in)

25-pin host connector

Power ground 1

1 Power Ground 17

Power connector

MS-890 Industrial Automation Scanner User’s Manual

18 Power

25 3

4

1 2 Trigger connector

1-3

Page 16

Connect the System

Connecting the MS-890 with Wiring Box 1. Be sure that the wiring box power cord is not plugged in. 2. Connect the scanner to the host computer. 3. Use the 9-pin configuration connector shown below to connect with your computer. This port is useful for setting up, testing, and defaulting the scanner.

2 Receive 3 Transmit 5 Signal ground 9-pin host configuration connector

4. Connect power to the wiring box. 5. Apply power to the wiring box and confirm that the LED next to the right side power terminal is green and not red. 6. Disconnect power.

7. Plug the ribbon cable (provided with wiring box) into the bottom of the scanner. 8. Attach the scanner to the wiring box with the 4 screws provided. 9. Power-on the scanner.

1-4

MS-890 Industrial Automation Scanner User’s Manual

Page 17

Quick Start

Step 3, Position Scanner and Symbol • Set up a symbol at the distance that will be used in your application. Center line ofof Centerline scan window scan window

Scan range starts here

Scan Range Starts Here Note: Code 39 is the default symbology enabled. If you are uncertain as to the symbology type in your application, enable all symbologies by clicking the Autodiscriminate button in EZ Mode. Important: If using Interleaved 2 of 5 symbols in your application, verify that the number of characters in the symbols being scanned matches the symbol length enabled for the Interleaved 2 of 5 symbology (default is 10 and 6).

MS-890 Industrial Automation Scanner User’s Manual

1-5

Page 18

Install ESP

Step 4, Install ESP Easy Setup Program (ESP) is Microscan’s proprietary setup and testing application. The purpose of ESP is to provide a quick and easy way to set up and configure Microscan products. When the MS-890 is connected to a host computer (Windows Vista, XP, or 2000), ESP can be used to set up communication with a host, configure various firmware settings, and control verification processes. Important: To migrate MS-880 settings to MS-890 settings in ESP, refer to the beginning of Chapter 2, Using ESP.

If installing from the Microscan Tools CD: 1. Insert the Microscan Tools CD in your computer’s CD drive. 2. Choose ESP Software from the main menu. 3. Select the Current Version of ESP and follow the file download prompts.

If downloading from the Microscan website: 1. Go to http://www.microscan.com/downloadcenter 2. Create a new “myMicroscan” member account or, if you are already a member, enter your user name and password. 3. Click the Download Software link and extract the latest version of ESP to a directory of your choice. Note where your ESP.exe file is stored on your hard drive. 4. At the end of the installation process, the following icon will appear on your desktop:

5. Click the ESP icon to start the program.

System Requirements for ESP • 166 MHz Pentium processor (recommended) • Windows Vista, XP, or 2000 operating system • Internet Explorer 5.0 or higher • 64 MB minimum RAM • 40 MB minimum disk space

1-6

MS-890 Industrial Automation Scanner User’s Manual

Page 19

Quick Start

Step 5, Select Model When you start ESP, this menu will appear:

1. Select the MS-890 from the menu and click OK. If you do not want to make this selection every time you start ESP, uncheck “Show this dialog at startup”. 2. Click Yes when the following dialog appears:

Note: If you need to select another model later, click the Switch Model button near the top of the screen.

MS-890 Industrial Automation Scanner User’s Manual

1-7

Page 20

Autoconnect

Step 6, Autoconnect 1. Select the appropriate port and click Start when the following dialog appears.

Note: If your communications port is not the default COM1, use the dropdown menu to change your port. Once you have chosen the correct port, click Start to connect. When you are connected, you will see the green connection indicator in the status bar at the bottom right of your screen:

2. If the connection attempt fails, click the Autoconnect button, select a different communications port, and try again.

Note: If your RS-232 host settings cannot be changed to match the scanner’s settings, select Connect... from the Connect menu in the menu toolbar, and then click the Force Connect box when you see the dialog shown at left. 1-8