Page 211
Raster/Laser
Raster/Laser by Embedded Menu To access the Raster/Laser Framing menu, send <@> to open the Calibration Setup menu and type the number 2.
Raster Settings Type the letter T to increment the Top Offset and an R to decrement. Notice that the Top Offset reading at the bottom of the menu changes accordingly. Type the letter B to increment the Bottom Offset and V to decrement. Sweep Rate, Raster Status, and Raster On/Off are explained more fully in Raster Setup on page 10-3.
Laser Settings Laser settings are also dynamically updated at the bottom of the menu. Full instructions and menus for laser operations can be found in Laser Framing on page 10-7. Press the enter key (CR) to return to the main calibration menu or ESC to leave the Auto Calibration Setup menu entirely.
MS-890 Industrial Automation Scanner User’s Manual
10-9
Page 212
Raster/Laser by Embedded Menu
10-10
MS-890 Industrial Automation Scanner User’s Manual
Page 213
11 Terminal Contents Terminal Window........................................................................................................................ 11-2 Find............................................................................................................................................. 11-3 Send ........................................................................................................................................... 11-4 Macros........................................................................................................................................ 11-5 Terminal Window Menus ............................................................................................................ 11-6
This section describes the Terminal window and macro functions. Note: The characters NUL, <, >, and , can only be entered through embedded menus, not through ESP or serial commands.
MS-890 Industrial Automation Scanner User’s Manual
11-1
Page 214
Terminal Window
Terminal Window Click this button to bring up the Terminal view.
The following window will appear: Copy, paste, save
Type text here to find matching text in the Terminal window.
Terminal screen
Type serial commands here.
Clear screen
Macros listed on this bar
Click on Macros arrow to Add Macro, Remove Macro, or Edit Macro. Click on desired Macro to run.
The Terminal screen allows you to send serial commands to the scanner by using Macros, by copying and pasting, or by typing commands in the Send text field. The Terminal screen also displays symbol data or information from the scanner. You can also right-click on the Terminal screen to bring up a menu of further options.
11-2
MS-890 Industrial Automation Scanner User’s Manual
Page 215
Terminal
Find The Find function allows you to enter text strings to be searched for in the Terminal window. For example, a series of symbols have been scanned into the Terminal view and you want to determine if a particular symbol whose data begins with “ABC” has been read. 1. Type “ABC” into the Find box.
2. Press Enter. The first instance of “ABC” will be highlighted in the Terminal window. 3. Click the Find button to the right of the text field to locate additional instances of “ABC”.
MS-890 Industrial Automation Scanner User’s Manual
11-3
Page 216
Send
Send The Send function in ESP’s Terminal allows you to enter serial commands and then send them to the scanner. 1. Type the command into the Send box.
2. Press Enter. 3. Click the Send button to the left of the text field to send.
11-4
MS-890 Industrial Automation Scanner User’s Manual
Page 217
Terminal
Macros Macros can be stored in a macro selection bar, edited in a separate window, and executed by clicking on the macro name.
Click on Next Row to see the next row of macros
Click on the first arrow here to see Add Macro or Default Macros. When you default macros, the entire macros set is restored to their original macro commands.
Click on subsequent arrows to edit macros.
When you click on the macro name, the macro is executed in the Terminal window. If this is a command, it is sent to the scanner at the same time that it is displayed.
Editing a Macro When you click the arrow next to any macro and select Edit, the following appears:
You can edit an existing macro or type in the Macro Name text field and define it in the Macro Value text field. Click OK.
MS-890 Industrial Automation Scanner User’s Manual
11-5
Page 218
Terminal Window Menus
Terminal Window Menus Right-click on the Terminal window to display the following menu: • Copy selected text to clipboard. • Paste from Terminal or computer text. • Clear all text in Terminal window. • Select All text in the Terminal window. • Save... brings up a save as dialog box. • Change Font... of data text, brings up a text dialog. • Change Echo Font... to change typed in text or commands. • Change Background Color of Terminal window. • Default Settings changes all the above back to default settings.
Terminal Dropdown Menu The dropdown Terminal menu has Capture Text and Save Current Text functions, as well as the functions defined above. • Capture lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened. You can select Pause to interrupt the capture flow or Stop to end the flow and open the file. • Save Current Text... saves all text in the Terminal window to a text file of your choice.
11-6
MS-890 Industrial Automation Scanner User’s Manual
Page 219
12 Utilities Contents Serial Utility Commands ............................................................................................................. 12-2 Read Rate .................................................................................................................................. 12-4 Counters ..................................................................................................................................... 12-6 Device Control ............................................................................................................................ 12-8 Differences from Default........................................................................................................... 12-10 Master Database ...................................................................................................................... 12-11 Digital Bar Code ....................................................................................................................... 12-16 Firmware................................................................................................................................... 12-17 Autodiscriminate ....................................................................................................................... 12-19 Scanner Status Requests......................................................................................................... 12-20
Utility commands are generally commands that are performed during scanner operations to check read rates, determine read rates or perform miscellaneous operations on scanner hardware. Serial utility commands are not prefaced with a K and a numeric code, nor do they require an initialization command (<A> and <Z>). They can be entered from within any terminal program or from within ESP in the Terminal window. Note: The characters NUL, <, >, and , can only be entered through embedded menus, not through ESP or serial commands.
MS-890 Industrial Automation Scanner User’s Manual
12-1
Page 220
Serial Utility Commands
Serial Utility Commands Command Type Read Rate
Counters
Device Control
Matchcode
Master Database
Firmware
Symbologies
Trigger
12-2
Command <C> <Cs> <Cp> <Cm> <Ce> <CPDF> <J> <N> <O> <T> <U> <V> <W> <X> <Y> <H> <I> <K500> <K501> <L1> <L2> <L3> <E> <F> <G> <Gn> <Mn> <Mn?> <Mn,> <!> <!b> <!a> <!c> <#> <#b> <#a> <P> <Q> <R> <S> <char>
Name Enter Read Rate Test Enter Multisymbol Read Rate Test Enter Percent Test Enter Multisymbol Percent Test Extended Read Rate Enter Percent PDF Read Rate Test Exit Read Rate and Percent Test No Read Counter No Read Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Enable Laser Scanning (Laser On) Disable Laser Scanning (Laser Off) Motor On Motor Off Programmable Output 1 Pulse Programmable Output 2 Pulse Programmable Output 3 Pulse Enable Matchcode Type Disable Matchcode Type Store Next Symbol to Database Index 1 Store Next Symbol to Database Index n Download Master Symbol Data to Database Index n Display Master Symbol Data from Database Index n Delete Master Symbol from Database Index n Display Checksums for Boot Code and Application Code Display Checksum for Boot Code Display Checksum for Application Code Display Checksum for Raster Code Display Boot Code and Application Code Part Number Display Boot Code Part Number Display Application Code Part Number Autodiscriminate All Symbologies Enable Code 39 Only Enable Codabar Only Enable Interleaved 2/5 Only Serial Trigger Character
MS-890 Industrial Automation Scanner User’s Manual