Page 131

I/O Parameters

Output Indicators Note: System features such as autocalibration and EZ Button setup may illuminate scanner LEDs regardless of parameter settings.

Green Flash Mode Usage: Definition: Serial Cmd: Default: Options:

Used as a visual verification that a Good Read has occurred. An array of green LEDs in the front of the scanner can be programmed to flash in response to user-defined conditions. <K750,green flash LED status,green flash duration> Good Read 0 = Disabled 1 = Good Read 2 = Static Presentation 3 = Match 4 = Mismatch

Disabled Green flash LEDs are disabled.

Good Read Green flash LEDs will flash when a Good Read condition is met or when Matchcode is enabled and a match occurs.

Static Presentation Mode Static Presentation Mode is used in conjunction with Continuous Read Mode: <K200,0>. When operating in Static Presentation Mode, the red LEDs will illuminate while the scanner is searching for a symbol in Continuous Read Mode. When a symbol is placed in the field of view and a Good Read occurs, the green LEDs will illuminate and stay on for the duration of time set in Green Flash Duration. Only one read will occur during that time unless more than one symbol is enabled in Number of Symbols. Note: If Static Presentation Mode is selected but the scanner is not in Continuous Read, the Green Flash will not occur. To use Static Presentation: 1. Enable Continuous Read. 2. Select the number of symbols. 3. Enable Static Presentation in Green Flash Mode. 4. Select the read time in Green Flash Duration.

MS-890 Industrial Automation Scanner User’s Manual

6-9

Page 132

Output Indicators

Match The green LEDs will flash when a match condition is met. If multisymbol is enabled, then green flash LEDs will illuminate only if all symbols qualify as a match. If matchcode is disabled, then this mode will activate the LEDs on a Good Read.

Mismatch Same as Match, except that LEDs will illuminate on a mismatch.

6-10

MS-890 Industrial Automation Scanner User’s Manual

Page 133

I/O Parameters

Green Flash Duration Usage: Definition: Serial Cmd: Default: Options:

Provides visual verification that a Good Read has occurred. When a Good Read occurs, the green LEDs will illuminate and stay on for the time set in the Green Flash Duration value. <K750,green flash mode,green flash duration> 100 (1 second) 0 to 65535 (in 10 ms increments)

MS-890 Industrial Automation Scanner User’s Manual

6-11

Page 134

Beeper

Beeper Usage:

Can be used as an audible verification that either a good read or a No Read has occurred.

Definition:

A beep is emitted either after each good read of a symbol or after each No Read. Note: Beeper will also sound if any of the following occur: • The scanner is defaulted. • A send/save command from ESP or an Exit command from any embedded menu. • A <Z>, <Zp>, <Zd>, or <K701,,1> command is sent.

Beeper Status Serial Cmd:

<K702,status>

Default:

On Good Read

Options:

0 = Disabled 1 = On Good Read 2 = On No Read

6-12

MS-890 Industrial Automation Scanner User’s Manual

Page 135

I/O Parameters

Serial Verification Usage:

These commands are useful in removing any doubt about the scanner’s acceptance and response to host configuration commands. For example, if the current preamble is “SOM” and <Kd1, START> is entered, the scanner will echo back <Kd1, SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore it is rejected and the existing “SOM” message is echoed back and remains the preamble message.

Definition:

Allows the user to verify configuration command status.

Serial Command Echo Status Important Note: ESP will not function whenever this command is enabled. Definition:

When enabled, a configuration command received from the host is echoed back to the host with the resultant settings.

Host

Scanner

Function:

If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change.

Serial Cmd:

<K701,serial command echo status,serial command beep status,control/ hex output>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Serial Command Beep Status Important: ESP will not function whenever this command is enabled. Usage:

Used to audibly verify the acceptance and validity of a command.

Definition:

Causes the scanner to beep once whenever a K command is entered to indicate that the command was accepted and processed.

Function:

If an invalid command is entered, the scanner beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response.

Serial Cmd:

<K701,serial command echo status,serial command beep status,control/ hex output>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

MS-890 Industrial Automation Scanner User’s Manual

6-13

Page 136

Serial Verification

Control/Hex Output Usage:

Useful for viewing settings with binary characters when using serial command on a terminal.

Definition:

Determines the response to a Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as the two characters: ^M. When set to Hex, the output is the hex character.

Serial Cmd:

<K701,serial command echo status,serial command beep status,control/ hex output>

Default:

Control

Options:

0 = Control

6-14

1 = Hex

MS-890 Industrial Automation Scanner User’s Manual

Page 137

I/O Parameters

EZ Button The EZ Button has four positions, selectable by the length of time the button is held down, and indicated by one, two, three, and four beeps in succession. Each position can be programmed for any of eight options. Definition: Serial Cmd: Default: Options:

Serves as a master switch to enable/disable the EZ Button status. <K770,global status,default on power-on,load configuration database, save for power-on> Enabled 0 = Disabled 1 = Enabled 2 = Trigger 3 = Unlatch Outputs 4 = Parameter Switch

Global Status Disabled When set to Disabled, the EZ Button does not function.

Enabled When selected, the EZ Button is enabled and the function of each button position is selected by the EZ Button Mode command.

Trigger When selected, the EZ Button acts as a trigger for the scanner to start and end read cycles. All other button operations are inactive. In External Level: In External Edge:

The read cycle endures for as long as the EZ Button is pressed, unless a timeout occurs and Timeout is enabled for End of Read Cycle. As with Level, Edge allows a read cycle to be initiated by pressing the EZ Button, but unlike Level, the read cycle ends with a Good Read output, a timeout, or a new trigger.

Unlatch Outputs In this configuration, the EZ Button will unlatch any logic outputs that have been latched.

Parameter Switch The parameter switch toggles between custom defaults and power-on settings. The condition is the same as that achieved by sending the <Arc> and <Arp> commands consecutively.

MS-890 Industrial Automation Scanner User’s Manual

6-15

Page 138

EZ Button

Default on Power-On Definition:

Serial Cmd: Default: Options:

When enabled, if the EZ Button is held down on power-on the scanner will default to customer defaults and save for power-on. This is the same as sending a <Zrc> command. <K770,global status,default on power-on,load configuration database, save for power-on> Enabled 0 = Disabled 1 = Enabled

Load Configuration Database Definition:

Serial Cmd: Default: Options:

Allows the user to load the Configuration Database with calibration results. When the user performs a calibration using the EZ Button, all the database entries are moved down one index and the results of the calibration are saved to index 1. The results will be saved as current settings as well. <K770,global status,default on power-on,load configuration database, save for power-on> Enabled 0 = Disabled 1 = Enabled

Save for Power-On Definition: Serial Cmd: Default: Options:

6-16

If enabled, after calibration is complete, all parameters will be saved for power-on. <K770,global status,default on power-on,load configuration database, save for power-on> Disabled 0 = Disabled 1 = Enabled

MS-890 Industrial Automation Scanner User’s Manual

Page 139

I/O Parameters

EZ Button Modes Usage: Definition: Serial Cmd: Options:

Useful for performing multiple, repetitive tasks at the work site. Allows the user to program each of the EZ Button’s 3 positions from a selection of 10 modes. <K771,single beep,two beeps,three beeps>

Single Beep 0 = Disabled 1 = Read Rate 2 = Calibration 3 = Save for Power-On 5 = Load New Master 9 = Bar Code Configuration

Two Beeps 0 = Disabled 1 = Read Rate 2 = Calibration 3 = Save for Power-On 5 = Load New Master 9 = Bar Code Configuration

Three Beeps 0 = Disabled 1 = Read Rate 2 = Calibration 3 = Save for Power-On 5 = Load New Master 9 = Bar Code Configuration

Disabled When set to disabled, the associated button position will have no function associated with it, and the position will be skipped over.

Read Rate Read Rate will be initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from the terminal. To exit Read Rate Mode quickly press and release the EZ Button.

Calibration Calibration will be initiated when the associated button position is selected. To abort calibration, quickly press and release the EZ Button.

Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from the terminal.

Load New Master Functions in the same way as new master pin input whenever the associated button position is selected. The new master pin’s Consecutive Decode requirement holds true for this function.

Bar Code Configuration Enables Bar Code Configuration mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button. MS-890 Industrial Automation Scanner User’s Manual

6-17

Page 140

EZ Button Modes

EZ Button Operation Single Beep (Position #1) Hold down button until a single beep is heard.

Two Beeps (Position #2) Hold down button until two quick beeps are heard.

Three Beeps (Position #3) Hold down button until three quick beeps are heard.

6-18

MS-890 Industrial Automation Scanner User’s Manual