Page 141

I/O Parameters

Input 1 Definition:

A programmable, discrete input used to reset counters, outputs or control optoelectrical settings.

Usage:

For example, an application is setup so that a mismatch stops the production line by using outputs in a latch mode. A push-button switch can be connected to the input pin so that when pressed, it unlatches the output, allowing the line to resume operations.

Input Mode Definition:

Determines the functionality of the input.

Serial Cmd:

<K730,input mode,active state>

Default:

Disabled

Options:

0 = Disabled 1 = Reset Counts 2 = Unlatch Output

Disabled Definition:

When set to Disabled, there is no effect on operation.

Reset Counts Usage:

Primarily used in test mode. Can also be used to reset counters daily.

Definition:

When set to Reset Counts, a transition to the active state of the input will cause the scanner to reset the internal counters (See Counters on page 12-6).

Unlatch Output Definition:

This setting is used in combination with any of the three discrete outputs that are in Unlatch Mode 1. A transition to the active state will clear any of the three outputs that were previously latched.

Active State Definition:

Determines the function of the input pin.

Serial Cmd:

<K730,input mode,active state>

Default:

Active Closed

Options:

0 = Active Open

1 = Active Closed

Note: If set to Match or Mismatch, Symbol Data Output Status will not take effect unless Matchcode Type is enabled and a master symbol is loaded into memory. MS-890 Industrial Automation Scanner User’s Manual

6-19

Page 142

Configurable Output 1

Configurable Output 1 Output On Usage: Definition: Serial Cmd: Default: Options:

This option provides discrete signalling to host software to control external devices such as PLCs and relays. It is useful for routing, sorting, and to prevent mis-packaging and mis-routing. Sets the discrete output functions for specific user-selected conditions. Allows the user to set the conditions under which an output (or outputs) will be activated. <K810,output on,output state,pulse width,output mode> Mismatch or No Read 0 = Mismatch or No Read 1 = Match or Good Read 2 = Mismatch 3 = No Read 4 = Trend Analysis 5 = [reserved] 6 = Diagnostic Warning 7 = In Read Cycle

Note: If Output On is set to Mismatch/No Read or Match/Good Read, a transition (switching) will not occur unless Matchcode Type is enabled and a master symbol is loaded into memory.

Mismatch or No Read Activates a discrete output when the data does not match that of the master symbol or the symbol has not been decoded before the end of the read cycle.

Match or Good Read Activates a discrete output when the symbol data matches the master symbol. Note: If you want to output for a Good Read and Matchcode is not enabled, you can enable any output for Match.

Mismatch Activates a discrete output whenever the symbol data does not match that of the master symbol.

No Read Activates a discrete output whenever the symbol data is not decoded before the end of the read cycle.

6-20

MS-890 Industrial Automation Scanner User’s Manual

Page 143

I/O Parameters

Trend Analysis Activates discrete output when a trend analysis condition is met, depending on the trend analysis option enabled. Typically used when successful decodes are occurring but a discrete output is needed to flag a trend in quality issues.

Diagnostic Warning Activates discrete output when a diagnostic warning condition is met, depending on the diagnostic option enabled. Typically used when a discrete indication of a diagnostic condition is needed.

In Read Cycle Activates a discrete output when the scanner is in a read cycle.

MS-890 Industrial Automation Scanner User’s Manual

6-21

Page 144

Configurable Output 1

Output State Definition: Serial Cmd: Default: Options:

Sets the active electrical state of the discrete output. <K810,output on,output state,pulse width,output mode> Negative 0 = Negative 1 = Positive

Pulse Width Definition: Serial Cmd: Default: Options:

Sets the time in 10 ms increments that the discrete output remains active. <K810,output on,output state,pulse width,output mode> 50 1 to 65535 (Divide the number entered on the command line by 100 for time in seconds)

Output Mode Definition: Serial Cmd: Default: Options:

Sets the condition in which the discrete output is de-activated. <K810,output on,output state,pulse width,output mode> Pulse 0 = Pulse 1 = Latch Mode 1 2 = Latch Mode 2 3 = Latch Mode 3

Pulse This is the default mode of operation in which the programmable output is activated when the Output On condition has been met and held active for the duration of the selected pulse width.

Latch Mode 1 (Unlatch on Input 1 Pin) In this mode the programmable output will be activated when the Output On condition is met. It will stay active until the state of the Input 1 pin changes from inactive to active or the proper mode is configured using the EZ Button. Important: To unlatch using the Input 1 pin, the input status must be set to “Unlatch Outputs”. To unlatch using the EZ Button, the button status must be set to Unlatch Mode.

Latch Mode 2 (Unlatch Opposite Condition) The programmable output is activated when the Output On condition has been met and held active until the opposite condition selected under Output On has been met. For example, if No Read is enabled under Output On, the programmable output will go active on a No Read and remain active until the opposite condition, a Good Read, occurs.

6-22

MS-890 Industrial Automation Scanner User’s Manual

Page 145

I/O Parameters

Latch Mode 3 (Unlatch Re-Enter Read Cycle) The programmable output is active when the Output On condition has been met and is held active until a new read cycle begins. Note: All of the Output On modes are inhibited when any Output on Warning is active for Output 1.

MS-890 Industrial Automation Scanner User’s Manual

6-23

Page 146

Configurable Output 1

Trend Analysis Output 1 Note: Output On in Output 1 Parameters must be set to Trend Analysis for this output to function. Usage: Definition:

Example:

6-24

Useful in cases where the user doesn’t want to shut down for one condition but wants to monitor quality and read conditions. Applies Trend Analysis settings to Output 1. With Trend Analysis, the user can track the occurrences and frequency of mismatches, No Reads, and the number of reads per trigger, and output the results to any of three outputs. Trend Analysis Mode = No Read Number of Triggers = 25 triggers (read cycles) Number to Output On = 4 Decodes per Trigger = 1 In this example, the scanner will activate an output when 4 No Reads occur within a period of 25 triggers (read cycles), at 1 decode per trigger.

MS-890 Industrial Automation Scanner User’s Manual

Page 147

I/O Parameters

Trend Analysis Mode Definition: Serial Cmd: Default: Options:

Sets the trend condition (Mismatch, No Read, Decodes/Trigger, Bad Symbol, or No Symbol) that will activate the output. <K780,trend analysis mode,number of triggers,number to output on, decodes/trigger threshold> No Read 0 = Mismatch 1 = No Read 2 = Decodes/Trigger Threshold 3 = Bad Symbol 4 = No Symbol

Mismatch Output will be activated when the number of mismatches equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.

No Read Output will be activated when the number of No Reads equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.

Decodes/Trigger Threshold Output will be activated when the number of decodes equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.

Bad Symbol Output will be activated when the number of Bad Symbol occurrences equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.

No Symbol Output will be activated when the number of No Symbol occurrences equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.

MS-890 Industrial Automation Scanner User’s Manual

6-25

Page 148

Configurable Output 1

Number of Triggers Definition: Serial Cmd: Default: Options:

The number of triggers to examine for the trend analysis condition. <K780,trend analysis mode,number of triggers,number to output on, decodes/trigger threshold> 0 0 to 255

Number to Output On Usage:

Definition:

Serial Cmd: Default: Options:

Example: If Number to Output On is set to 3 and Trend Analysis Mode is set to No Read, then the output will not be activated until 3 No Reads have occurred. Sets the number of Trend Analysis Mode events (mismatches, No Reads, or reads/trigger as configured by Trend Analysis Mode) to occur within the trigger evaluation period before activating the associated output. <K780,trend analysis mode,number of triggers,number to output on, decodes/trigger threshold> 0 0 to 255

Decodes/Trigger Threshold Definition:

Serial Cmd: Default: Options:

6-26

When set to this mode, and when the appropriate output is set to output on trend analysis, the scanner will function in a Decodes per Trigger mode during the read cycle and the trend analysis operation. Output will be activated based on whether or not the symbol decode count at the end of the read cycle crosses the decodes per trigger threshold. Note: Although this setup causes the scanner to function in a Decodes per Trigger mode, the decode count will only be appended to the symbol data if the status of the Decodes per Trigger command is enabled. <K780,trend analysis mode,number of triggers,number to output on, decodes/trigger threshold> 0 0 to 65535

MS-890 Industrial Automation Scanner User’s Manual

Page 149

I/O Parameters

Diagnostics Output 1 Note: Output On in Output 1 Parameters must be set to Diagnostic Warning for this output to function.

Over Temperature Serial Cmd: Default: Options:

<K790,over temperature,service threshold,[unused],laser current high,laser current low,low temperature> 0 0 = Disabled 1 = Enabled

Service Threshold Serial Cmd: Default: Options:

<K790,over temperature,service threshold,[unused],laser current high,laser current low,low temperature> 0 0 = Disabled 1 = Enabled

Laser Current High Serial Cmd: Default: Options:

<K790,over temperature,service threshold,[unused],laser current high,laser current low,low temperature> 0 0 = Disabled 1 = Enabled

Laser Current Low Serial Cmd: Default: Options:

<K790,over temperature,service threshold,[unused],laser current high,laser current low,low temperature> 0 0 = Disabled 1 = Enabled

Low Temperature Serial Cmd: Default: Options:

<K790,over temperature,service threshold,[unused],laser current high,laser current low,low temperature> 0 0 = Disabled 1 = Enabled

MS-890 Industrial Automation Scanner User’s Manual

6-27

Page 150

Configurable Output 2

Configurable Output 2 Note: Output 2 has the same parameters and default settings as Output 1. Serial Cmd:

<K811,output on,output state,pulse width,output mode>

Trend Analysis Output 2 Note: Output On under Output 2 Parameters must be set to Trend Analysis for this output to function. Serial Cmd:

<K781,trend analysis mode,trigger evaluation period,number to output on,decodes/trigger threshold>

Diagnostics Output 2 Note: Output On under Output 2 Parameters must be set to Diagnostic Warning for this output to function. Serial Cmd:

6-28

<K791,over temperature,service threshold,unused,laser current high,laser current low,low temperature>

MS-890 Industrial Automation Scanner User’s Manual