Page 101

Symbologies

EAN-128 Status Usage:

Definition:

Serial Cmd:

Sometimes called the “shipping code,” it is used as a standard to track a product from site to site with a single symbol that contains categories of information identifiable across industries worldwide. A subset of Code 128, with extended features using application identifiers to define the meaning and format of fields that immediately follow them. For more information, refer to the AIM website at: http://www.aimglobal.org/standards/aimpubs.asp

Default:

<K474,Code 128 status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets status,application record padding status,minimum ratio distance> Note: Code 128 serial command fields for K474 precede EAN-128. Disabled

Options:

0 = Disabled

1 = Enabled

2 = Required

If set to Enabled, symbols can be read with or without a function 1 character in the first position. If set to Required, the symbol must have a function 1 in the first position and conform to EAN format in order to decode the symbol. Note: Code 128 must also be Enabled for EAN-128 to function.

MS-890 Industrial Automation Scanner User’s Manual

5-7

Page 102

Code 128/EAN-128

Output Format (EAN-128) Usage:

Definition: Serial Cmd:

Default: Options: Standard:

Application Record:

Application Record is useful in applications in which the software can use application record formatting to help automate the processing of its EAN-128 data. Offers an option between Standard EAN-128 and Application Record format. <K474,Code 128 status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets status,application record padding status,minimum ratio distance> Standard 0 = Standard 1 = Application Record When set to Standard, EAN-128 application identifiers and data fields are sent, but none of the formatting (separators, parentheses, padding) will be included. Application Record is a variation of EAN-128 that allows the user to define separators between data fields, enclose application identifiers in parentheses, and enable padding (zeros) for variable length fields.

Note: If an illegal Application Record format is detected, the scanner will process it as a No Read and output a No Read message (if enabled).

Application Record Separator Status (EAN-128) Definition:

Default:

When enabled, a separator character is inserted between application records. <K474,Code 128 status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets status,application record padding status,minimum ratio distance> Disabled

Options:

0 = Disabled

Serial Cmd:

1 = Enabled

Application Record Separator Character (EAN-128) Definition: Serial Cmd:

Default: Options:

Defines an ASCII character as an application record separator. <K474,Code 128 status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets status,application record padding status,minimum ratio distance> , (comma) User Defined ASCII character

Note: Output Format must be set to Application Record before this parameter can take effect. 5-8

MS-890 Industrial Automation Scanner User’s Manual

Page 103

Symbologies

Application Record Brackets Status (EAN-128) Definition: Serial Cmd:

Default:

When enabled, parentheses ( ) are added to enclose application identifiers. <K474,Code 128 status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets status,application record padding status,minimum ratio distance> Disabled

Options:

0 = Disabled

1 = Enabled

Note: Output Format must be set to Application Record before this parameter can take effect.

Application Record Padding Status (EAN-128) Definition:

Serial Cmd:

Default: Options:

Padding is the insertion of zeros to make up the maximum length of a variable application record data field, except for the last field which does not require padding. When enabled, padding is included. When disabled, padding is omitted. Note: Padding is never added to fixed length fields or to the last data field of a symbol. Enabling or disabling Record Padding will have no effect on these. <K474,Code 128 status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets status,application record padding status,minimum ratio distance> Disabled 0 = Disabled 1 = Enabled

Note: Output Format must be set to Application Record before this parameter can take effect.

Minimum Ratio Distance (Code 128) Definition:

Serial Cmd:

Default: Options:

Determines the error tolerance level. Normal enforces a requirement for normal error tolerance. High enforces a requirement for high element-to-element quality. Highest enforces a requirement for very high element-to-element quality. <K474,Code 128 status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets status,application record padding status,minimum ratio distance> Normal 0 = Normal 1 = High 2 = Highest

MS-890 Industrial Automation Scanner User’s Manual

5-9

Page 104

Interleaved 2 of 5

Interleaved 2 of 5 Usage:

Interleaved 2 of 5 has been popular because it is the most dense symbol for printing numeric characters less than 10 characters in length; however, Microscan does not recommend this symbology for any new applications because of inherent problems (truncation, for example).

Definition:

A dense, continuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check digit is highly recommended.) Important: You must set Symbol Length in order to decode I 2/5 symbols.

Interleaved 2 of 5 Status Serial Cmd:

<K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,guard bar status,range mode>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Check Digit Status (Interleaved 2 of 5) Usage:

Typically not used but can be enabled for additional security in applications where the host requires redundant check digit verification.

Definition:

An error correcting routine in which the check digit character is added.

Serial Cmd:

<K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,guard bar status,range mode>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Check Digit Output Status (Interleaved 2 of 5) Definition:

When enabled, a check digit character is sent along with the bar symbol data for added data security.

Serial Cmd:

<K472,status,check digit status,check digit output,symbol length #1,symbol length #2,guard bar status,range mode>

Default:

Disabled

Options:

0 = Disabled

5-10

1 = Enabled

MS-890 Industrial Automation Scanner User’s Manual

Page 105

Symbologies

Symbol Length #1 (Interleaved 2 of 5) Usage:

With I–2/5, two symbol lengths can be defined. When using only one symbol length in an application, setting Symbol Length #2 to 0 (zero) to ensure data integrity is recommended.

Definition:

Allows user to define the symbol length. Because I–2/5 is a continuous symbology, it is prone to substitution errors. Hence, a symbol length must be defined and a symbol must contain an even number of digits. Note: If start, stop or check digits are used, they are not included in the symbol length count.

Serial Cmd:

<K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,guard bar status,range mode>

Default:

10

Options:

0 to 128, even Note: Since I 2/5 characters are paired, symbol length must be set to an even number. If Check Digit is enabled, add 2 to your symbol length. For example, if your symbol is 10 characters plus a check digit, then enable Symbol Length for 12. Note: Typically, when printing an I 2/5 symbol with an odd number of digits, a 0 will be added as the first character.Note: If both Symbol Length #1 and Symbol Length #2 are set to 0, then I–2 of 5 will be variable.

Symbol Length #2 (Interleaved 2 of 5) Usage:

If using a second symbol, a zero or any even symbol length from 2 to 64 may be specified. If not using a second symbol, set Symbol Length #2 to 0 to ensure data integrity.

Definition:

Allows user to define a second symbol length for I–2/5.

Serial Cmd:

<K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,guard bar status,range mode>

Default:

6

Options:

0 to 128, even Since I 2/5 characters are paired, symbol length must be set to an even number. If Check Digit is enabled, add 2 to your symbol length. For example, if your symbol is 10 characters plus a check digit, then enable Symbol Length for 12. Note: Typically, when printing an I 2/5 symbol with an odd number of digits, a 0 will be added as the first character. Note: If both Symbol Length #1 and Symbol Length #2 are set to 0, then I–2 of 5 will be variable.

MS-890 Industrial Automation Scanner User’s Manual

5-11

Page 106

Interleaved 2 of 5

Guard Bar (Interleaved 2 of 5) Note: Whenever Guard Bar is enabled, the presence of guard bars is required for decoding to take place. Usage:

Useful when I 2 of 5 multisymbols are enabled to prevent false data output. This typically occurs with highly tilted or skewed symbols.

Definition:

A guard bar is a heavy bar, at least 2 times the width of the wide bar, surrounding the printed I 2 of 5 symbol and helping to prevent false reads.

Serial Cmd:

<K472,status,check digit status,check digit output status,symbol length #1, symbol length #2,guard bar,range mode>

Default:

Disabled

Options:

0 = Disabled 1 = Enabled

Range Mode (Interleaved 2 of 5) Note: Whenever Guard Bar is enabled, the presence of guard bars is required for decoding to take place. Definition:

When enabled, this feature causes symbol length # 1 and symbol length # 2 to form of a range of lengths that can be decoded. For example, if symbol lengths of 10 and 6 are enabled, those are the lengths that can be decoded. Note that either length can serve as the minimum or maximum.

Serial Cmd:

<K472,status,check digit status,check digit output status,symbol length #1, symbol length #2,guard bar,range mode>

Default:

Disabled

Options:

0 = Disabled 1 = Enabled

5-12

MS-890 Industrial Automation Scanner User’s Manual

Page 107

Symbologies

Codabar Usage:

Used in photo-finishing and library applications. Used in some medical applications at one time, but not typically used in newer applications.

Definition:

Codabar is a 16-character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths.

Codabar Status Serial Cmd:

<K471,status,start and stop match status,start and stop output status,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output status>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Start and Stop Match Status (Codabar) Usage:

Used to increase security of symbology.

Definition:

Requires the Codabar start and stop characters (a, b, c, or d) to match before a valid read can occur.

Serial Cmd:

<K471,status,start and stop match status,start and stop output status, large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output status>

Default:

Enabled

Options:

0 = Disabled

1 = Enabled

Start and Stop Output Status (Codabar) Usage:

Used to verify matching.

Definition:

Causes the start and stop characters to be transmitted with symbol data.

Serial Cmd:

<K471,status,start and stop match status,start and stop output status, large intercharacter gap,fixed symbol length status,symbol length,check character type,check character status,check character output status>

Default:

Enabled

Options:

0 = Disabled

1 = Enabled

MS-890 Industrial Automation Scanner User’s Manual

5-13

Page 108

Codabar

Large Intercharacter Gap (Codabar) Usage:

It is helpful for reading symbols that are printed out of specification. Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled since enabling Large Intercharacter Gap (over 3x) could cause a narrow margins (5x) to be interpreted as an intercharacter gap.

Definition:

Instructs the scanner to read symbols with gaps between characters exceeding three times the narrow element width.

Serial Cmd:

<K471,status,start and stop match status,start and stop output status,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output status>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Fixed Symbol Length Status (Codabar) Usage:

Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted.

Definition:

When enabled, the scanner will check the symbol length against the fixed symbol length field. When disabled, any length would be considered a valid symbol.

Serial Cmd:

<K471,status,start and stop match status,start and stop output status,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output status>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Symbol Length (Codabar) Definition:

Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check character characters). The scanner ignores any symbol not having the specified length.

Serial Cmd:

<K471,status,start and stop match status,start and stop output status,large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status>

Default:

10

Options: 1 to 128 Note: Fixed Symbol Length Status must be enabled for Symbol Length to take effect. Note: Because of symbology limitations, setting Symbol Length to any number less than four will produce undetermined results. 5-14

MS-890 Industrial Automation Scanner User’s Manual

Page 109

Symbologies

Check Character Type (Codabar) Definition:

Allows the user to select the check character type Codabar will use.

Serial Cmd:

<K471,status,start and stop match,start and stop output status,large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status>

Default:

Disabled

Options:

0 = Disabled 1 = Modulus 16 2 = NW 7 3 = Both Modulus 16: Used in the photo-finishing market. NW 7: Used in Japanese markets.

Check Character Output Status (Codabar) Usage:

For additional security a check character can be added to the symbol.

Definition:

When enabled, the check character character is sent along with the symbol data. When disabled, symbol data is sent without the check character.

Serial Cmd:

<K471,status,start and stop match,start and stop output status,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output status>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

MS-890 Industrial Automation Scanner User’s Manual

5-15

Page 110

UPC/EAN

UPC/EAN Usage:

Definition:

Used primarily in POS application in the retail industry. It is commonly used in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length numeric, continuous symbology. UPC can have two- or five-digit supplemental symbol data following the normal symbol. The U.P.C., Version A (UPC-A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the scanner will read UPC-A and UPC-E only.

UPC Status Serial Cmd: Default:

<K473,UPC status,EAN status,supplemental status,separator status,separator character,supplemental type> Disabled

Options:

0 = Disabled

1 = Enabled

EAN Status Usage:

Default:

UPC/EAN is the European version of the UPC symbology and is used in European market applications. Note: UPC must be enabled for EAN to take effect. EAN is a subset of UPC. When enabled, the scanner will read UPC version A, UPC version E, EAN 13, and EAN 8. It also appends a leading zero to UPC version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC version A symbols is not desired, disable UPC/EAN. Note: The extra character identifies the country of origin. <K473,UPC status,EAN status,supplemental status,separator status,separator character,supplemental type> Disabled

Options:

0 = Disabled

Definition:

Serial Cmd:

5-16

1 = Enabled

MS-890 Industrial Automation Scanner User’s Manual