Page 91
Read Cycle
Automatic Gain Control (AGC) Settings Important: AGC settings apply to both AGC and symbol detection.
Symbol Detect Status Usage:
During the read cycle, the scanner counts the number of bar and space transitions defined in the Transition Counter. If the count matches or exceeds the threshold, the scanner will perform AGC routines.
Definition:
AGC is the acronym for Automatic Gain Control. AGC increases the depth of field by attempting to maintain signal strength at a constant level regardless of the range of the symbol.
Serial Cmd: <K505,symbol detect status,minimum number of transitions> Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Minimum Number of Transitions Usage:
Can be useful in certain application where extraneous objects in the field of view might require a higher threshold.
Definition:
Determines the number of bar/space transitions that must be read before a symbol is considered present and AGC can be resolved.
Serial Cmd: <K505,symbol detect status,minimum number of transitions> Default:
14
Options:
1 to 255
MS-890 Industrial Automation Scanner User’s Manual
4-21
Page 92
Maximum Element
Maximum Element Definition:
Maximum Element represents the maximum bar element width that is allowed before a video reset occurs (default to white). Caution: Do not change this parameter unless instructed by a Microscan representative.
Serial Cmd: <K502,maximum element> Default:
400 (x 0.01% of scan)
Options:
50 to 5000
4-22
MS-890 Industrial Automation Scanner User’s Manual
Page 93
Read Cycle
Tracking Adjustment Definition:
Sets a tracking value for the scanner’s analog circuitry. Changes to tracking adjustment should be made by Autocalibration.
Serial Cmd: <K520,tracking adjustment> Default:
40
Options:
5 to 127
MS-890 Industrial Automation Scanner User’s Manual
4-23
Page 94
Tracking Adjustment
4-24
MS-890 Industrial Automation Scanner User’s Manual
Page 95
5 Symbologies Contents Symbologies by ESP .................................................................................................................... 5-2 Symbologies Serial Commands ................................................................................................... 5-2 Code 39 ........................................................................................................................................ 5-3 Code 128 / EAN-128 .................................................................................................................... 5-6 Interleaved 2 of 5........................................................................................................................ 5-10 Codabar...................................................................................................................................... 5-13 UPC/EAN.................................................................................................................................... 5-16 Code 93 ...................................................................................................................................... 5-19 Pharmacode ............................................................................................................................... 5-20 PDF417 ...................................................................................................................................... 5-22 Narrow Margins / Symbology ID................................................................................................. 5-24 Background Color....................................................................................................................... 5-26 Autodiscriminate ......................................................................................................................... 5-27
This section describes the various symbol types that can be read and decoded by the scanner. Code 39 is enabled by default. To enable all symbologies, right-click Autodiscrimination under Symbol Type in the Utilities menu and select Enable, or send a <P> serial command to the scanner from the Terminal window. Note: The characters NUL, <, >, and , can only be entered through embedded menus, not through ESP or serial commands.
MS-890 Industrial Automation Scanner User’s Manual
5-1
Page 96
Symbologies by ESP
Symbologies by ESP
Click this button to bring up the Symbologies menu.
To change a setting, double-click the setting and use your cursor to scroll through the options.
To open nested options, single-click the +.
Symbologies Serial Commands Command Title Narrow Margins/Symbology ID Background Color Code 39 Codabar Interleaved 2 of 5 UPC/EAN
Code 128/EAN-128 Code 93 PDF417 Pharmacode
5-2
Command Format <K450,narrow margins status,symbology identifier status> <K451,background color> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start and stop match,start and stop output, large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output> <K472,status,check digit status,check digit output,symbol length #1,symbol length #2,guard bar status,range mode status> <K473,UPCstatus,EAN status,supplemental status,separator status, separator character,supplemental type> <K474,Code 128 status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets status,application record padding status,minimum ratio distance> <K475,status,fixed symbol length status,symbol length> <K476,status,raster sweeps before decode attempt,fixed symbol length status,symbol length,decode at end of read> <K477,status,fixed symbol length status,symbol length,minimum number of bars,bar widths,direction,fixed threshold value>
MS-890 Industrial Automation Scanner User’s Manual
Page 97
Symbologies
Code 39 Usage:
Code 39 is considered the standard for non-retail applications.
Definition:
An alphanumeric symbol with unique start/stop symbol patterns, composed of 9 black and white elements per character, of which 3 are wide.
Code 39 Status Serial Cmd:
<K470,status,check character status,check character output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set>
Default:
Enabled Note: This is the only symbol type enabled by default.
Options:
0 = Disabled
1 = Enabled
Check Character Status (Code 39) Serial Cmd:
<K470,status,check character status,check character output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Check Character Output (Code 39) Usage:
Check Character Output Status, added to the symbol, provides additional security.
Definition:
When enabled, the check character is read and sent along with the symbol data. When disabled, symbol data is sent without the check character. Note: With Check Character Output Status and an External or Serial trigger option enabled, an invalid check character calculation will cause a No Read message to be transmitted at the end of the read cycle.
Serial Cmd:
<K470,status,check character status,check character output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
MS-890 Industrial Automation Scanner User’s Manual
5-3
Page 98
Code 39
Large Intercharacter Gap (Code 39) Usage:
Large Intercharacter Gap is helpful for reading symbols that are printed out of specification. Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled since a large intercharacter gap (over 3x) could cause a narrow margins (5x) to be interpreted as an intercharacter gap.
Definition:
When enabled, the scanner can read symbols with gaps between symbol characters that exceed three times (3x) the narrow element width.
Serial Cmd:
<K470,status,check character status,check character output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length Status (Code 39) Usage:
Helps prevent truncations and increases data integrity by ensuring that only a fixed symbol length will be accepted.
Definition:
When enabled, the scanner will check the symbol length against the symbol length field. If disabled, any length is considered a valid symbol.
Serial Cmd:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Symbol Length (Code 39) Definition:
Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check character characters). The scanner ignores any symbol not having the specified length.
Serial Cmd:
<K470,status,check character status,check character output,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
Default:
10
Default:
1 to 128
5-4
MS-890 Industrial Automation Scanner User’s Manual
Page 99
Symbologies
Full ASCII Set (Code 39) Usage:
Default:
Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) User must know in advance whether or not to use Full ASCII Set option. Since Full ASCII Set requires two symbol words to encode one character, it is less efficient. Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign and percent symbol. When Full ASCII Set is enabled, the scanner can read the full ASCII character set, from 0 to 255. <K470,status,check character status,check character output,large intercharacter gap,fixed symbol length status,symbol length,full ASCII set> Disabled
Options:
0 = Disabled
Definition:
Serial Cmd:
1 = Enabled
MS-890 Industrial Automation Scanner User’s Manual
5-5
Page 100
Code 128/EAN-128
Code 128/EAN-128 Usage:
Code 128/EAN-128 is a smaller symbology, and is useful in applications with tight spots and high security needs.
Definition:
A very dense alphanumeric symbology. It encodes all 128 ASCII characters; it is continuous, has variable length, and uses multiple element widths measured edge to edge.
Code 128 Status Serial Cmd:
<K474,Code 128 status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets status,application record padding status,minimum ratio distance>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled (Serial Standard)
2 = Edge
3 = Serial Standard and Edge
Note: Code 128 must be Enabled for EAN-128 to function.
Fixed Symbol Length Status (Code 128) Definition:
When enabled, the scanner will check the symbol length against the symbol length field. When disabled, any length is considered a valid symbol.
Serial Cmd:
<K474,Code 128 status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets status,application record padding status,minimum ratio distance>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Symbol Length (Code 128) Usage:
Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted.
Definition:
Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check characters). The scanner ignores any symbol not having the specified length.
Serial Cmd:
<K474,Code 128 status,fixed symbol length status,symbol length,EAN-128 status,output format,application record separator status,application record separator character,application record brackets status,application record padding status,minimum ratio distance>
Default:
10
Options:
1 to 128
Note: Fixed Symbol Length Status must be enabled for Symbol Length to take effect. 5-6
MS-890 Industrial Automation Scanner User’s Manual