The text of a manual · part 19 of 23
MS-820 Industrial Bar Code Scanner User's Manual: MS-820 Industrial Bar Code Scanner User's Manual, pages 181 to 190
Pages 181 to 190 of 222, from MS-820 Industrial Bar Code Scanner User's Manual
The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-820
Page 181
Electrical Specifications Additional Isolated Output Circuit Examples Secondary Relay 1 to 28 V
Power +
Scanner Output
Outputs (+)
V
PLC
Input
Outputs (+)
Outputs (–)
Output
PLC
Power +
RELAY
Isolated Scanner
Scanner
Isolated Scanner
PLC GND
Power ground Outputs (–) Power ground
Appendices
MS-820 Industrial Bar Code Scanner User’s Manual
A-7
Page 182
Appendix B
Optoisolator Inputs All discrete inputs can be fully isolated pulses as PNP or NPN circuits. Inputs include trigger and new master. Generic Waveform Characteristicsa Minimum
Maximum
VIN-HIGH/IIN-HIGH 4.5 V/3.0mA
28 V/23mA
VIN-LOW/IIN-LOW
0 V/0mA
2.0V/1mA
Pulse Widthmin
48 µS a. New Master is activated by applying a voltage of 5 to 28 VDC between New Master (+) and internal ground.
Input (+) I load Input (–)
New master pin input (–) is internally grounded.
Input Examples Fully Optoisolated
Appendices
PNP Source +V
Isolated Scanner V CC
NPN Source (trigger only)
Isolated Scanner V CC
+V Input (+)
Signal Input (+)
Input (–)
Input (–)
Signal
New master pin input (–) is internally grounded.
Not Optoisolated Non-isolated Scanner V CC
PNP Source Power (+) Input (+)
+V
NPN Source (trigger only)
Non-isolated Scanner V CC
Signal
Power (+)
+V
Input (+) Input (–)
Input (–) Power ground Power ground
New master pin input (–) is internally grounded.
A-8
MS-820 Industrial Bar Code Scanner User’s Manual
Signal
Page 183
IB-131 Interface Module
Appendix C, IB-131 Interface Module The IB-131 interface module simplifies connecting to the scanner by providing separate ports for the host, power supply, trigger and network. The network port is used for multidrop or daisy chain configurations. See the following pages for configuration diagrams and a list of cables offered by Microscan for ease of connectivity when using the IB-131. Table A-4 Host 25-pin Connector
Table A-7 Scanner 15-pin Connector
Pin
Pin
Function
Function
External ground
1
Power + 10 to 28 VDC (out)
2
Transmit data (RS-232)
2
Transmit RS-232/RS-422 (–)
3
Receive data (RS-232)
3
Receive RS-232/RS-422 (–)
4
RTS
4
Power/Signal Ground
5
CTS
5
Trigger (–) (out)
6
Output 2 (+)
6
RTS/Aux Transmit/RS-232/RS-422 (+)
7
Signal ground
7
Output 1 (+)
8
Output 1 (+)
8
Default configuration
9
Trigger (–)
9
Trigger (+) (out)
10
Trigger (+)
10
CTS/Aux Receive RS-232/RS-422 (+)
11
Default configuration
11
Output 3 (+)
13
Receive data RS-422 (+)
12
New master/OMR (out)
14
Transmit data RS-422 (–)
13
External ground
15
Output 3 (+)
14
Output 2 (+)
16
Receive data RS-422 (–)
15
Output 1/2/3 (–)
17
Output 1/2/3 (–)
19
Transmit data RS-422 (+)
25
New master/OMR (in)
Table A-5 Trigger 4-pin Connector Pin
Function
Table A-8 Network 25-pin Connector Pin
Function
1
Ground
2
Aux Receive RS-232
3
Aux Transmit RS-232
1
Power + 10 to 28VDC (out)
6
Output 2 (+)
2
Trigger (–) (in)
7
Signal ground
3
Power Ground
8
Output 3 (+)
4
Trigger (+) (in)
13
Receive data/RS-422 (+)
Table A-6 Power 3-pin Connector Pin
Function
Appendices
1
14
Transmit data/RS-422 (–)
15
Output 3 (+)
16
Receive data/RS-422 (–)
1
Power Ground
17
Output 1/2/3 (–)
3
Power + 10 to 28VDC (in)
19
Transmit data (RS-422+)
MS-820 Industrial Bar Code Scanner User’s Manual
A-9
Page 184
Appendix C
Mounting holes 3 places 1.25" (3.18 cm)
3.2" (8.13 cm)
Trigger
Network
Power Supply
Scanner
Electrical: Voltage Input: Regulated +10 to 28VDC Cabling: RS-232 Cable: 61-300026 Multidrop Cable: 61-100030 Daisy Chain Cable: 61-100029 Mechanical: Length: 3.2 in. (8.13 cm) Width: 3.15 in. (8 cm) Height: 0.75 in. (1.9 cm)
Host
0.17: (0.43 cm) dia. 3. places
.75" (1.9 cm)
Figure A-2 IB-131 Mechanical
Scanner to IB-131 MS-820
61-100011 (6 feet) U
Scanner
Host
Host
With this configuration the scanner communicates directly with the host through the IB131. IB-131: 99-400005-02 (1 per MS-820) Host RS-232 Serial Cable: 61-300026 (for PC) Power Supply: 97-10004-05 (for each scanner) Trigger: 99-440001-10 (for each scanner)
Power
Power supply 97-10004-05
Network
Appendices
3.15" (8 cm)
Trigger
Trigger 99-440001-10
Figure A-3 Scanner/IB-131 Typical Setup
A-10
MS-820 Industrial Bar Code Scanner User’s Manual
Page 185
IB-131 Interface Module
Multidrop MS-911 MS-820
61-100031 (6 Feet)
Scanner Cable (3 Feet)
Network
Scanner Host
Power
U
61-100030 (10 Feet)
Network
U
Scanner Host
This setup allows the user to link multiple scanners together, using only one host. IB-131: 99-400005-02 (1 per MS-820) Multidrop Cable: 61-100030 (connects multiple IB-131s) Power Supply: 97-10004-05 (for each scanner) Trigger: 99-440001-10 (for each scanner)
Trigger
Power
Trigger 99-440001-10
Power Supply 97-10004-05
Trigger
Power Supply 97-10004-05
Trigger 99-440001-10
Figure A-4 IB-131 Multidrop Setup
Daisy Chain
Slave Scanner
Master Scanner
Appendices
Power
Power Supply 97-10004-05
Daisy Chain Cable 61-100029 (1 Foot)
U Scanner
Trigger
Power
Trigger 99-440001-10
Power Supply 97-10004-05
Network
U
Scanner Network
To Host 61-3000026
Host
Trigger: 99-440001-10 (for each scanner)
61-100031 (6 Feet)
Host
This setup allows the user to link multiple scanners together, using only one host. IB-131: 99-400005-02 (1 per MS-820) Daisy Chain Cable: 61100029 (connects multiple IB-131s) Power Supply: 97-10004-05 (for each scanner)
Trigger
To Next Slave Scanner Trigger 99-440001-10
Figure A-5 Scanner/IB-131 Daisy Chain Setup
MS-820 Industrial Bar Code Scanner User’s Manual
A-11
Page 186
Appendix D
Appendix D, Serial Configuration Commands The following table is a list of all the available serial configuration commandsalphabetical. These commands are also listed at the beginning of each applicable chapter. For utility (operational) commands see Table 11-1, “Summary of Utility Serial Commands,” on page 11-3.
Appendices
Table A-9 Complete List of Serial Configuration Commands Command Title
Cmd
Host Port Parameters
Ka
<Kabaud,parity,stop bits,data bits>
Auxiliary Port Parameters
Ky
<Kyaux port mode,baud,parity,stop bits,data bits,daisy chain status,daisy chain ID>
Host Protocol
Kf
<Kfprotocol>
LRC
Kc
<Kcstatus>
Response Timeout
KA
<KAresponse timeout>
Intercharacter Delay
KB
<KBintercharacter delay>
Preamble
Kd
<Kdstatus,preamble>
Postamble
Ke
<Kestatus,postamble>
Comm. Status Request
KT?
<KT?>
Triggering Mode
Kg
<Kgtrigger mode,filter time>
End of Read Cycle
Kh
<Khmode,timeout>
Serial Trigger Character
Ki
<Kicharacter>
External Trigger State
Kj
<Kjexternal trigger state>
Decodes Before Output
Km
<Kmdecodes before output>
Multilabel
KL
<KLnumber of labels,multilabel separator>
Narrow Margins/Symbology ID
Ko
<Konarrow margins status,symbology ID status>
Background Color
Kx
<Kxbackground color>
Code 39
Kp
<Kpstatus,check digit status,check digit output status,large intercharacter gap,fixed code length status,fixed code length,full ASCII>
Interleaved 2 of 5
Kr
<Krstatus,check digit,check digit output,length 1,length 2>
UPC/EAN
Ks
<Ksstatus,EAN status,supplementals status,separator char>
PDF417
K[
<K[status,,fixed code length status,fixed code length>
Code 128
Kt
<Ktstatus,fixed length,length,,,,,,>
UCC/EAN-128 (subset of Code 128)
Kt
<Kt,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding
Codabar
Kq
<Kqstatus,start & stop match status,start & stop output status,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output>
Code 93
K!
<K!status,fixed code length status,fixed code length>
A-12
Format
MS-820 Industrial Bar Code Scanner User’s Manual
Page 187
Serial Configuration Commands Command Title
Format
AIAG
KZ
<KZAIAG status, ID1, status1, ID2, status2, ID3, status3, ID4, status4, *ID5a,ID5b,ID5c, status5, ID6, status6, ID7, status7, ID8, status8, ID9, status9, ID9, status10, ID11, status11, ID12, status12>
Code Type Status Request
KW?
<KW?>
Match Code Type
Kn
<Kntype,sequential matching,match start position,match length,wild card character,sequence on noread,sequence on every mismatch>
Master Label Data Base Size
KM
<KMnumber of master labels>
New Master Pin
Kz
<Kzstatus>
Operations Status Request
KV?
<KV?>
Background Color
Kx
<Kxbackground color
Code Type Status Request
KW?
<KW?>
Noread Message
Kk
<Kkstatus,output>
Laser On/Off
KC
<KCstatus,laser on/off status,laser framing status,laser off time,laser on time>
Serial Verification
KS
<KSserial command status,serial command beep status,control/hex output>
Beeper
Ku
<Kustatus,volume>
Output 2
Kw
<Kwoutput on,active state,pulse width,number before output>
Output 3
K‘
<K‘output on,active state,pulse width,number before output>
Output 1
Kv
<Kvoutput on,active state,pulse width,number before output>
Output 2
Kw
<Kwoutput on,polarity,pulse width,# before output>
Output 3
K‘
<K‘output on,polarity,pulse width,# before output>
Bar Code Output
Kl
<Klstatus,when to output>
Partial Output
KY
<KYstatus,start position,length>
Operational Command Output Format
K/
<K/status>
Scanner Output Status Request
KX?
<KX?>
Scanner Type (factory)
KP
<KPdensity>
Scan Speed (factory)
KE
<KEscan speed>
Gain/Tracking (factory)
KD
<KDgain,tracking>
Transition Trigger Sampling Rate
KH
<KHtransition sample status,transition sample rate threshold>
No Barcode Output
KN
<KNstatus,message>
MS-820 Industrial Bar Code Scanner User’s Manual
A-13
Appendices
Cmd
Page 188
Appendix D Command Title
Cmd
Format
K’
<K’status,message>
KU?
<KU?>
Raster Setup
KR
<KRstatus,top offset,bottom offset,sweep rate,read cycle on/off>
Warning Message Status
K"
<K"status1,laserhi,laserlo,novram corrupt>
Laser Overcurrent
K;
<K;message>
Laser Undercurrent
K:
<K:message>
Over-temperature
K+
<K+deg,message>
Under-temperature
K-
<K-deg,message>
Lifetime Hours
K$
<K$hours10,message>
Present Operating TemK% perature
<K%deg> (read only)
Counts
K_
<K_powerups,resets> (read only)
Time Since Last Reset
K@
<K@hours,minutes> (read only)
All Status Request
K?
<K?>
Appendices
Bad Barcode Output Scanner Setup Status Request
A-14
MS-820 Industrial Bar Code Scanner User’s Manual
Page 189
Serial Command Format
Appendix E, Serial Command Format Serial commands are of two types: utility and configuration.
Rules that apply to both utility and configuration commands • A less than < and greater than > characters enclose the commands. • Commands and data are “case sensitive.” That is, characters must be entered as upper or lower case, as specified.
Serial Utility Commands These are sent during operations and are not followed by a <A> or <Z>. See Table 11-1, “Summary of Utility Serial Commands,” on page 11-3.
Serial Configuration “K” Commands See Appendix E, “Serial Command Format” on page A-15.
Serial Configuration Command Conventions • All data fields (except the last) must be followed by a comma (without a space). • The following characters cannot be used: , < > NUL. • All fields preceding a modified field must be included. • If there is no change in preceding fields, then commas alone can be entered in these fields. For example, if only the last field in the following command is changing, <Ka4,1,0,0> can be entered as <Ka,,,0>. • All fields following a modified field can be omitted. For example, to change Baud Rate, send <Ka3>.
MS-820 Industrial Bar Code Scanner User’s Manual
A-15
Appendices
These begin with a single K character followed by a single character, data fields, and an initializing command, as follows: <Kparameterdata,data,...etc.><initializing command> An initializing command <A> or <Z> always follows the command. A <Z> initializes the scanner’s memory and saves for power-on; an <A> initializes the scanner’s memory but does not save for power-on. For example, to enable UPC and save the change for power-on, send <K1><Z>. To change Baud Rate and reset without saving changes for power-on, send <Ka3><A>.
Page 190
Appendix E Concatenating Configuration Commands Commands can be concatenated (added together) in a single string or data block.
Serial Command Status Request To ensure that any command was received and accepted, you can send the Show Scanner Status command: <?>. The status of a specific serial command can be requested by entering the command followed by a question mark.
Entering Special Characters in Serial Commands To enter control characters within a serial command, hold down the control key while typing the desired character.
Entering Special Characters in Embedded Menus
Appendices
Control Characters Control characters entered on the command line are displayed in the menu as mnemonic characters, such as: <CR><LF><NUL><NUL>. Press SP (the space bar) once, then enter the control character by holding down the control key and simultaneously pressing the desired character. For example to define a line feed, press SP, then Control and J simultaneously. It is displayed as ^J on the command line and as <LF> in the menu when the screen is refreshed.
To Define a Carriage Return as a Character Press SP, then CR. It is displayed as ^M on the command line and as <CR> in the menu when the screen is refreshed.
To Define a Space as a Character Press SP twice. It is displayed as a blank space in the menu when the screen is refreshed. While it appears that nothing has been assigned, the hex value 20 will be sent during data transmission.
To Select NUL as the Character Press SP, then a 0 (zero). It is displayed as <NUL> in the menu when the screen is refreshed.
A-16
MS-820 Industrial Bar Code Scanner User’s Manual