Page 191
ASCII Table
Appendix F, ASCII Table Table A-10 ASCII Table with Control Characters Hex 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
Mne NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
Ctrl ^ ^A ^B ^C ^D ^E ^F ^G ^H ^I ^J ^K ^L ^M ^N ^O ^P ^Q ^R ^S ^T ^U ^V ^W ^X ^Y ^Z ^[ ^\ ^] ^^ ^_
Dec 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
Hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
Ch SP ! “ # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
Dec 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
Hex 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
Ch @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
MS-820 Industrial Bar Code Scanner User’s Manual
Dec 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
Hex 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
Ch ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ D
A-17
Appendices
Dec 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Page 192
Appendix F Table A-11 Communication Protocol Commands Protocol Command Control Characters Hex (Mnemonic displayed (Entered in menu or Code on Microscan menu) serial command)
Effect of Command
^D
04
Reset
REQ
^E
05
Request
EOT
^D
04
Reset
STX
^B
02
Start of Text
ETX
^C
03
End of Text
ACK
^F
06
Acknowledge
NAK
^U
15
Negative Acknowledge
XON
^Q
11
Begin Transmission
XOFF
^S
13
Stop Transmission
Appendices
RES
A-18
MS-820 Industrial Bar Code Scanner User’s Manual
Page 193
Embedded Menus
Appendix G, Embedded Menus In addition to ESP-MP, you can also use a communications menu such as Microsoft’s HyperTerminal to establish communication with Microscan’s embedded menus.1 1. With your host connected to the configuration port, set your host communications settings as follows: 9600, 7, 1, and Even. 2. Set Flow Control to None. 3. Make the communications port selection. (Usually COM 1 or COM 2 for desktops and COM 1 for laptops.) 4. Upon connection, send a <D> command to bring up the main menu.
Appendices Menu navigation commands are case sensitive. Use the space bar or N to advance to the next item, CR (return key) to select a highlighted item, B to return to the previous item, M to return to the previous menu, and ESC to return to the Main menu or to exit the program. When exiting the program, you will be prompted to save your active settings for power up (Y or N). Typing Y will be equivalent to saving with a <Z> command.
1. If you are using Microsoft’s HyperTerminal program, you may find that the initial screen is unviewable when you call up the program with the <D> command. If this occurs, simply exit the embedded menu with a ESC, E, and N sequence and repeat the <D> command. MS-820 Industrial Bar Code Scanner User’s Manual
A-19
Page 194
Appendix H
Appendix H, Defaulting/Saving/Initializing Defaults are original or saved settings. Defaulting occurs when default settings (from flash or user-saved NOVRAM) are restored. Defaulting might be necessary if you have make temporary changes, communications between the scanner and another device are lost or interrupted, or you are using incompatible equipment (for example, a terminal that is set at 9600 baud communicating with a scanner that is set at 38.4K baud). Initializing occurs whenever any command or set of commands is implemented. Active Memory (SRAM) is where the scanner’s active settings are stored during use. These are not available on power-up. User-saved NOVRAM (non-volatile random access memory) is where the scanner’s operating parameters are stored for power-on. It can be changed by user command. Flash Defaults is where the scanner’s default download/boot programs are stored. It can only be changed by downloading application/boot codes.1
Appendices
Defaulting Restore NOVRAM Defaults to Active Memory • Restores user-defined NOVRAM settings to active memory.
<An>
• Initializes serial configuration commands in active memory and resets counters to zero.
Initialize Active Memory
By Serial Command Send <An> command to the scanner.
By ESP (There is no equivalent ESP command.) Restore Flash Defaults to Active Memory • Restores flash defaults to memory. • Initializes serial configuration commands in active memory and resets counters to zero.
User-Saved NOVRAM
<Ad>
Send <Ad> command to the scanner.
Initialize Active Memory
• Does not save settings to NOVRAM for power-on.
By Serial Command
Flash Defaults
User-Saved NOVRAM
By ESP 1. Right-click in the configuration window and select Default All ESP Settings. 2. Right-click and select Save to Scanner, Send and Save. 1. See your Microscan sales representative to access the latest application codes.
A-20
MS-820 Industrial Bar Code Scanner User’s Manual
Flash Defaults
Page 195
Defaulting/Saving/Initializing Restore Flash Defaults to Active Memory and for Power-on Caution: Defaulting the scanner to flash default settings will overwrite user-saved NOVRAM settings. • Restores flash defaults to memory.
<Zd>
Active Memory
• Restores flash defaults to user-saved NOVRAM for power-on. • Initializes serial configuration commands in active memory and resets counters to zero.
Initialize
User-Saved NOVRAM
Flash Defaults
By Serial Command Send <Zd> command to the scanner.
By ESP 1. Right-click in the configuration window and select Default All ESP Settings. 2. Right-click and select Save to Scanner, Send and Save.
By Hardware Default
2. Locate pins or wires that have continuity to pins4 and8 on the back of the scanner (see figure A-8 on page A-27). If using an IB-131, locate pins 7 and 11 on the host connector (see Table A-3 on page A-5). Caution: Be certain that the correct pins are located. Connecting the wrong pins could cause serious damage to the unit. 3. Momentarily connect these wires (or pins) and listen for a series of short beeps. 4. Within 3 seconds, connect them again. A longer beep should be heard. If not, repeat the process.
MS-820 Industrial Bar Code Scanner User’s Manual
A-21
Appendices
If a software default reset is not possible, it may be necessary to reset the scanner by shorting (connecting) specific pins. This procedure has the same effect as the <Zd> software command. 1. Apply power to the scanner.
Page 196
Appendix H
Saving Save Active Settings except Factory for Power-on • Initializes serial configuration commands in active memory and resets counters to zero.
Initialize
<Z >
• Saves all active settings except factory settings to NOVRAM for power-on.
By Software Command Send <Z> command to the scanner.
By ESP
Active Memory User-Saved NOVRAM
Flash Defaults
Right-click in the configuration window and select Save to Scanner, Send and Save.
Save Active Settings including Factory for Power-on
Appendices
• Initializes serial configuration commands in active memory and resets counters to zero. • Saves all active settings including factory settings to NOVRAM for power-on (factory settings include but are not limited to Focus, Gain, Tracking, and Scan Speed).
By Serial Command
Initialize
<Zp>
Active Memory and Factory Settings User-Saved NOVRAM
Flash Defaults
Send <Zp> command to the scanner.
By ESP Right-click in the configuration window and select Advanced, Send and Save, Including Factory.
A-22
MS-820 Industrial Bar Code Scanner User’s Manual
Page 197
Defaulting/Saving/Initializing
Initializing Initializing is a part of all save and default functions. It is also used as a follow-on to implement serial configuration commands into active memory. • Initializes serial configuration commands in <A > Initialize active memory and resets counters to zero. • Does not save settings to NOVRAM.
Active Memory
By Serial Command Send <A> after a serial configuration command or a string of serial configuration commands, for example, <Kd1><A>.
User-Saved NOVRAM
Flash Defaults
By ESP Right-click in the configuration window and select Save to Scanner, Send No Save. This will initialize all serial configuration changes that have been made in the current ESP session.
Loss of Communications
MS-820 Industrial Bar Code Scanner User’s Manual
A-23
Appendices
Making changes to communications with the host such as Baud Rate, Parity, Stop Bits, LRC, etc. without corresponding changes in linked device(s) can result in the loss of menu access through If this should occur, you should restore the scanner’s defaults.
Page 198
Appendix I
Appendix I, Position Scanner and Bar Code In positioning the scanner in relation to the bar codes being scanner, consider the following: • Position the scanner in a place devoid of sunlight, bright lights, or laser light from other sources. • Avoid excessive tilt, skew, or pitch. Maximum tilt is determined by label characteristics and the number of decodes required. Maximum skew is ±40°; maximum pitch is ±50°.1 • Pitch or skew label or scanner a minimum of ±15° to avoid specular reflection, the return of direct, non-diffused light.2 Skew axis Direction of travel
Appendices
Tilt axis Pitch axis
Scanner
Figure A-6 Scanner/Symbol Position
1. Maximum tilt is determined by label characteristics and number of decodes required. 2. The specular reflection zone is a narrow zone straight out from the scanner in which direct reflected light from a label can distort the scanner’s ability to distinguish bars from spaces.
A-24
MS-820 Industrial Bar Code Scanner User’s Manual
Page 199
Position Object Detector
Appendix J, Position Object Detector In a typical operation, a scanner will wait for bar code data only during a triggered read cycle. A read cycle is initiated by a “trigger” and can be in the form of a serial command from the host (internal trigger) or a signal from an object detector (external trigger). When an object detector (also called a sensor, package detector, etc.) is used, it is set up so that its beam will bounce off the approaching object and the resulting pulse will be sent to the scanner to begin the read cycle. Typically, a detector is positioned so that it will detect the presence of an object before its label can be scanned. An object detector is mounted in almost any position relative to the object as long as (1) the object passes within range of the detector and (2) direct or reflected light from the detector does not interfere with the scanner’s reception. As the item continues to move down the line, its label moves into the scanner beam and is read by the scanner. The drawing below shows a label in the picket fence direction with the object detector positioned so as not to cause interference.
Appendices
Bar-coded Object
Bar-coded Object
Object Detector
Scanner
Figure A-7 Object Detector
MS-820 Industrial Bar Code Scanner User’s Manual
A-25
Page 200
Appendix K
Appendix K, Test Decode Rate With a Static Label 1. Position a stationary bar code in front of a functioning scanner at the scan distance used in your application. 2. Enter a <C> command to see the decodes per second. The decode rate is the number of decoded scans per total number of scan. It will appear at the beginning of the data strings. Note: You can also enter a <Cp> command to see the percentage of decodes per scans. 3. Make a note of the decode rate. You will need this when calculating the number of decodes (see Appendix L, “Formulas for Number of Decodes” on page A-27). 4. End the test by sending the <J> command.
Appendices
Number of Decodes To ensure reliable scanning, you need to apply a minimum of five decodes to each bar code. This means that all variables, label speed, read range, etc. are significant. Note: Variations between labels are common. For this reason, the greater number of sample bar codes tested, the more likely you are to achieve optimum decode rates. In general, the number of decodes of a given bar code can be increased by: • Increasing label height • Decreasing label length • Increasing scan rate (spinning mirror speed) • Slowing label speed
With a Moving Label Before testing with a moving label, it is highly recommended that you calculate the expected number of decodes by using the formulas in Appendix L, “Formulas for Number of Decodes” on page A-27. Once you’ve mounted the scanner, established a good read rate with a stationary label, and calculated the number of decodes for your label speed, you can begin decoding with moving labels.
A-26
MS-820 Industrial Bar Code Scanner User’s Manual