Page 141

Chapter

Discrete I/0

9 Chapter Contents Output 1 .................................................................................................14-4 Output 2 .................................................................................................14-6 Output 3 .................................................................................................14-6

Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

MS-820 Industrial Bar Code Scanner User’s Manual

9-1

9–Discrete I/0

This section includes instructions for setting up conditions for changing input/output electrical transitions for control of internal and external devices. A discrete I/O (in/ out) signal is an electrical transition from one voltage level to another so that digital switching can occur.

Page 142

Discrete I/O by ESP Menu

Click this button to bring up the Outputs menu.

To change a setting, double-click the setting and use your curser to scroll through the options.

Discrete I/O by Serial Command

9–Discrete I/0

Command Title Output 1 Output 2 Output 3 Scanner I/O Status Request

9-2 cmds

Format

Kv Kw K‘

<Kvoutput on,active state,pulse width,number before output> <Kwoutput on,active state,pulse width,number before output> <K‘output on,active state,pulse width,number before output>

KX?

<KX?>

MS-820 Industrial Bar Code Scanner User’s Manual

Page 143

Chapter 9 Discrete I/0

Discrete I/O by Embedded Menus For information on accessing the embedded menus, see “Embedded Menus” on page A-19. From the Main menu, scroll down through the options and select the following screen:

9–Discrete I/0

MS-820 Industrial Bar Code Scanner User’s Manual

9-3

Page 144

Output 1

Output 1 Definition: Usage:

Sets the discrete output functions for specific user-selected conditions. This option provides switching to host software to control external devices such as PLCs and relays. It is useful for routing and sorting and to prevent mis-packaging and mis-routing.

Output On Definition: Serial Cmd: Default: Options:

Allows the user to set the conditions under which an output (or outputs) will be activated. <Kvoutput on,active state,pulse width,number before output> Noread 0 = Mismatch Or Noread 1 = Match (or good read) 2 = Mismatch 3 = Noread

Note: If Output On is set to Mismatch Or Noread, Match, or Mismatch, a transition (switching) will not occur unless Matchcode Type is enabled and a master label is loaded into memory.

Mismatch or Noread

9–Discrete I/0

Definition:

Activates discrete output when the bar code data does not match that of the master label or the bar code has not been decoded before the end of the read cycle.

Match Definition:

Activates a discrete output when the bar code data matches the master label. Note: If you want to output for a good read and Matchcode is not enabled, you can enable any output for Match.

Mismatch Definition:

Activates a discrete output whenever the bar code data does not match that of the master label.

Noread Definition:

9-4

Activates a discrete output whenever the bar code data is not decoded before the end of the read cycle.

MS-820 Industrial Bar Code Scanner User’s Manual

Page 145

Chapter 9 Discrete I/0

Active State Definition: Serial Cmd: Default: Options:

Sets the active state of the discrete output. <Kvoutput on,active state,pulse width,number before output> Normally Open 0 = Normally Closed 1 = Normally Open

Pulse Width Definition: Serial Cmd: Default: Options:

Sets the time in 10 mS increments that the discrete output remains active. <Kvoutput on,active state,pulse width,number before output> 5 (.05 seconds). Corresponds to 50 mS displayed in the menu. 1 to 255 (0.01 to 2.55 seconds). Divide the number entered on the command line by 100 for time in seconds.

Number Before Output Definition: Usage: Serial Cmd: Default: Options:

Sets the number of events (matches, mismatches, or noreads as configured by Output On) that must occur before activating the associated output. For example, if Number to Output On is set to 3 and Output 1 is set to Noread, then Output 1 will not be activated until 3 noreads have occurred. <Kvoutput on,active state,pulse width,number before output> 0 0 to 255

9–Discrete I/0

MS-820 Industrial Bar Code Scanner User’s Manual

9-5

Page 146

Output 2

Output 2 Serial Cmd:

<Kwoutput on,active state,pulse width,number before output>

Output 2 has the same parameters and default settings as Output 1.

Output 3 Serial Cmd:

<K‘output on,active state,pulse width,number before output>

9–Discrete I/0

Output 3 has the same parameters and default settings as Output 1.

9-6

MS-820 Industrial Bar Code Scanner User’s Manual

Page 147

Chapter

Diagnostics

10 Chapter Contents Warning Messages ................................................................................10-4 Warning Message Status.......................................................................10-5 Laser High Warning ...............................................................................10-6 Laser Low Warning ................................................................................10-7 NOVRAM Reset Warning Status ...........................................................10-8 High Temperature Threshold .................................................................10-9 Low Temperature Threshold................................................................10-10 Lifetime Hours......................................................................................10-11

Important: Since Warning Messages and NOVRAM Messages are not enabled by default, these messages will not be displayed. However, if you suspect that erroneous defaults are occurring, enable Warning Messages and NOVRAM Messages by sending <K”1,,,1>. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

10–Diagnostics

MS-820 Industrial Bar Code Scanner User’s Manual

10-1

Page 148

Diagnostics by ESP Menu

Click this button to bring up the Diagnostic menu.

To change a setting, double-click the setting and use your curser to scroll through the options.

Diagnostics by Serial Command

10–Diagnostics

Command Title Warning Message Status

K”

Lifetime Hours Over-temperature Under-temperature Laser Overcurrent Laser Undercurrent Power On/Resets Counts Time Since Last Reset Present Operating Temperature

K$ K+ KK; K: K_ K@?

Format <K”warning message status,laser high status,laser low status,novram/reset warning status> <K$hours10,message> <K+degrees,message> <K-degrees,message> <K;message> <K:message> <K_powerups,resets> <K@?hours,minutes> (read only)

K%?

<K%?deg> (read only)

10-2

Cmds

MS-820 Industrial Bar Code Scanner User’s Manual

Page 149

Chapter 10 Diagnostics

Diagnostics by Embedded Menu For information on accessing the embedded menus, see “Embedded Menus” on page A-19. From the Main menu, scroll down through the options and select the following screen:

10–Diagnostics

MS-820 Industrial Bar Code Scanner User’s Manual

10-3

Page 150

Warning Messages

Warning Messages Important Note: Warning Message Status must be enabled before any warnings in this menu can be displayed. Definition:

Usage: Serial Cmd:

Warning messages that relate to the environment and condition of the scanner can be defined and set to activate specific outputs. Note: When enabled, the error condition will override all other operational modes configured for the output. When enabled, laser current and NOVRAM warning messages will be transmitted to the host or any active port whenever the pre-defined conditions are met. These messages serve as a flag to service a scanner or as an early warning that potential problems could arise. They are particularly useful in factories that run 24/7 and can’t afford down time. <K ”warning message status,laser high status,laser low status, novram/reset warning status>

Warning Message Status Function:

Usage: Serial Cmd:

10–Diagnostics

Default: Options:

When enabled, warning messages will be transmitted to the host or any active port. Note: This option must be enabled before any other warning messages can be transmitted. Alerts the user to impending failures or conditions that may soon cause failures. <K”warning message status,laser high status,laser low status, novram/reset warning status> Disabled 0 = Disabled 1 = Enabled

10-4

MS-820 Industrial Bar Code Scanner User’s Manual