Page 131

Chapter 8 Outputs Mismatch Definition:

Usage:

With Mismatch enabled, the scanner transmits bar code data whenever the bar code data information does NOT match the master label. Note: A noread can still be transmitted if enabled. Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container.

Good Read Definition:

Usage:

With Good Read enabled, the scanner transmits bar code data on any good read regardless of Matchcode Type setting. Note: A noread can still be transmitted if enabled. Good Read is used when an application requires all bar code data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified.

When to Output Bar Code Data Serial Cmd: Default: Options:

This command allows the user to choose when bar code data can be sent to the host. <Kloutput status,when to output> As Soon As Possible 0 = As Soon As Possible 1 = End of Read Cycle

8–Outputs

Definition:

As Soon As Possible Definition:

Usage:

Enabling As Soon As Possible causes bar code data to be sent to the host immediately after a bar code has been successfully decoded. Note: More than one decode might in fact be required to qualify as a good decode, depending on how Decodes Before Output is set. As Soon As Possible is useful in applications in which bar code data needs to be moved quickly to the host, typically when the host is making decisions based on bar code data.

MS-820 Industrial Bar Code Scanner User’s Manual

8-9

Page 132

Bar Code Output End of Read Cycle Definition:

Enabling End of Read Cycle means that bar code data does not get sent to the host until the read cycle ends with a timeout or new trigger. End of read cycle

Start of read cycle Read cycle Duration Host activates trigger

This is when host expects output

Figure 8-2 Read Cycle End of Read Cycle is useful in timing-based systems in which the host is not ready to accept data at the time it is decoded.

8–Outputs

Usage:

8-10

MS-820 Industrial Bar Code Scanner User’s Manual

Page 133

Chapter 8 Outputs

Laser Control Laser On/Off Status Definition: Usage: Serial Cmd: Default: Options:

When enabled, the laser is ON only during the read cycle. When disabled, the laser operates continuously. Laser On/Off extends the life of the laser. It is useful where there are significant time gaps between symbols. It also provides visual confirmation of a read cycle duration and minimizes laser exposure to people. <KC laser on/off status,laser framing status,laser off percentage,laser on percentage> Disabled 0 = Disabled, 1 = Enabled

Laser Framing Status Definition: Usage:

To adjust laser framing, click the Laser Control button, and Laser On/Off arrows up or down as shown here.

Scan beam direction

Laser Off Time

Laser On Time

ESP Laser Framing Control Figure 8-3 Laser Framing Pattern

MS-820 Industrial Bar Code Scanner User’s Manual

8-11

8–Outputs

Serial Cmd: Default: Options:

Sets the percentage of time the laser is ON during each scan so that only a selected portion of the scan width is effectively scanned. This is useful to avoid highly reflective objects, for filtering out unwanted signals and avoiding the wrong symbols. <KC laser on/off status,laser framing status,laser off percentage> Disabled 0 = Disabled, 1 = Enabled

Page 134

Laser Control Note: Because scan widths are not always perfectly symmetrical, the most effective way to setup laser framing is to experiment with the Laser On Percentage and Laser Off Percentage commands until you get the best results.

Laser Off Percentage Definition:

Serial Cmd: Default: Options:

Percentage of time that the laser is OFF during the scan width sweep. When Laser Framing is disabled, the laser is ON during the full scan. When Laser Framing is enabled, the laser remains OFF from the start of the scan and remains OFF for the specified percentage of the scan. Important: The combined values of Laser Off Percentage and Laser On Percentage cannot exceed 100 which is the duration of one scan. <KC laser on/off status,laser framing status,laser off percentage,laser on percentage> 20 1 to 80

8–Outputs

When setting up Laser Framing in ESP-MP, use the Laser Off Percentage and Laser Framing On Percentage arrows to constrain or expand the laser framing area. Laser On PercentageWhen setting up Laser Framing in ESP-MP, use the Definition:

Serial Cmd: Default: Options:

Percentage of time that the laser is ON during the scan width sweep. Whenever the Laser Off Percentage of the laser beam has expired, the Laser On Percentage begins and remains ON for the specified percentage of the scan. Duration of laser on time, in increments of 1/100th of the total scan width sweep. Important: The combined values of Laser Off Percentage and Laser On Percentage cannot exceed 100 which is the duration of one scan. <KC laser on/off status,laser framing status,laser off percentage,laser on percentage> 80 20 to 100

Laser Off Percentage and Laser Framing On Percentage arrows to constrain or expand the laser framing area.

8-12

MS-820 Industrial Bar Code Scanner User’s Manual

Page 135

Chapter 8 Outputs

Serial Verification Allows the user to verify configuration command status.

Serial Command Echo Status Definition: Function:

Usage:

Default: Options:

Serial Command Beep Status Definition: Function:

Usage: Serial Cmd: Default: Options:

Causes the scanner to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the scanner beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response. Used to audibly verify the acceptance and validity of a command. <KSserial command echo status,serial command beep status,control/hex output> Disabled 0 = Disabled 1 = Enabled

MS-820 Industrial Bar Code Scanner User’s Manual

8-13

8–Outputs

Serial Cmd:

When enabled, a configuration command received from the host is echoed back to the host with the resultant settings. If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change. This command is useful in removing any doubt about the scanner’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <Kd1, START> is entered, the scanner will echo back <Kd1, SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore it is rejected and the existing “SOM” message is echoed back and remains the preamble message. <KSserial command echo status,serial command beep status,control/hex output> Disabled 0 = Disabled 1 = Enabled

Page 136

Serial Verification

Control/Hex Output Definition:

Usage: Serial Cmd:

8–Outputs

Default: Options:

Determines the response to an Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as the two characters: ^M. When set to Hex, the output is the hex character. Useful for viewing settings with binary characters when using serial command on a terminal. <KSserial command echo status,serial command beep status,control/ hex output> Control 0 = Control 1 = Hex

8-14

MS-820 Industrial Bar Code Scanner User’s Manual

Page 137

Chapter 8 Outputs

Beeper Status Definition:

A beep is emitted either after each good read of a bar code label or after each noread. Note: Beeper will also sound if any of the following occur: • the scanner is defaulted • a send/save command from ESP or an Exit command from any embedded menu

Usage:

• a <Z>, <Zp>, <Zd>, or <KS,1> command is sent Can be used as an audible verification that either a good read or a noread has occurred.

Status Serial Cmd: Default: Options:

<Kustatus,volume> On Good 0 = Disabled 1 = On Good 2 = On Noread

8–Outputs

Volume Serial Cmd: Default: Options:

<Kstatus,volume> Level 4 0 = Off 1 = Level 1 2 = Level 2 3 = Level 3 4 = Level 4 5 = Level 5

MS-820 Industrial Bar Code Scanner User’s Manual

8-15

Page 138

Partial Output

Partial Output Definition: Usage:

When enabled, allows you to pre-select portions of labels to be transmitted by the scanner. In Multilabel mode, partial output is performed on each separate label. For example, if Start Position is set to 3 and Partial Length is set to 5, the following labels are transmitted as follows: 1234567890 as 34567 1234 as 34 123456789,abcde as “34567,cde” (two labels with separator) 12 as [blank]

Status

8–Outputs

Serial Cmd: Default: Options:

<KY status,start postion,length> Disabled 0 = Disabled 1 = Enabled

Start Position Definition: Serial Cmd: Default: Options:

Allows you to determine the first character from the beginning of a label to transmit. <KYstatus,start postion,length> 1 1 to 2710

Partial Length Definition: Serial Cmd: Default: Options:

8-16

Allows you to determine the number of characters to be transmitted. <KYstatus,start postion,length> 63 1 to 2710

MS-820 Industrial Bar Code Scanner User’s Manual

Page 139

Chapter 8 Outputs

Operation Command Output Definition: Usage: Serial Cmd: Default: Options:

Directs the scanner to bracket non-bar code scanner data outputs such as counters with command start and stop characters and echo the command to the screen. Useful when brackets are required to delineate certain scanner outputs such as counters. <K/ status> Enabled 0 = Disabled 1 = Enabled

8–Outputs

MS-820 Industrial Bar Code Scanner User’s Manual

8-17

Page 140

8–Outputs

Operation Command Output

8-18

MS-820 Industrial Bar Code Scanner User’s Manual