Page 81

Output Commands Serial Verification Format: <KSserial command echo status,serial command beep status,control/hex output> serial command echo status: 0 = Disabled 1 = Enabled serial command beep status: 0 = Disabled 1 = Enabled control/hex output: 0 = Control 1 = Hex

Example: To enable Serial Command Echo Status and Beep Status, and Hex output, send <KS1,1,1>.

Scanner Output Status Request Format: <KX?> Returns status of each command in the Scanner Output group.

3–Serial Config.

MS-810 Industrial Scanner User’s Manual

3-19

Page 82

Chapter 3

Setup Commands Scanner Type Important: sending the <Zp> command (see “Save Scanner Type, SPS, and Gain for Power-on” on page 4-12) will save the current setting for Scanner Type to NOVRAM. Format: <KPdensity> scanner density type:* 0 = Standard 1 = High Density * The “default” will depend on the type of scanner.

Example: Do not change the scanner density type unless instructed to do so by a Microscan representative.

3–Serial Config.

Scans per Second Format: <KEscans per second> scans per second (in 10 millisecond increments): Any number from 30 to 55. Default is 50 (500 sps) for Standard, 40 for Low and High Density. Example: To set the scanner to 400 scans per second, send <KE40>.

Auto Gain Control Important: Before saving any changes to Gain Adjustment (see “Save Scanner Type, SPS, and Gain for Power-on” on page 4-12), first record the optimized factory setting for future reference. Format: <KDgain adjustment,AGC samplings> gain adjustment: Default is 45 (nominal). Any number from 10 to 255.

AGC sampling: 0 = Disabled 1 = Leading Edge 2 = Continuous

Example: To set the gain threshold to 40 and the AGC status to Leading Edge, send <KD40,1,0>.

Scanner Setup Status Request Format: <KU?> Returns status of each command in the group.

3-20

MS-810 Industrial Scanner User’s Manual

Page 83

Chapter

4

Utilities

Chapter Contents Read Rate............................................................................................ 4-3 Trigger ................................................................................................. 4-5 Scanner ............................................................................................... 4-6 Counters .............................................................................................. 4-7 Master Label ........................................................................................ 4-9 Reset ................................................................................................. 4-11 Checksum .......................................................................................... 4-13 Code Type Commands...................................................................... 4-15

The Utilities menu can be accessed by clicking the Utilities button or selecting from the Utilities pull down menu. You can also send serial command strings to the scanner from a terminal window which you access by Clicking Terminal in ESP. Serial commands are enclosed in brackets <>.

MS-810 Industrial Scanner User’s Manual

4-1

4–Utilities

The Utilities menu allows you to send operational commands to the MS-810 to carry out routine operations “on the fly” as distinguished from serial configuration commands that are generally used during your initial setup.

Page 84

Chapter 4 Summary of Operational Commands Type

Read Rate

Trigger

Scanner

Counters

4–Utilities

Master Label

Reset

Checksum

Cmd <C> <Cp> <Cs> <Cm> <Ce> <J> <char> <H> <I> <KE> <KF> <L1> <L2> <N> <O> <T> <U> <V> <W> <X> <Y> <E> <F> <G> <)XXXX)> <)> <))> <A> <Ad> <An> <D> <Z> <Zd> <Zp> <#> <!> <?> <?1>

Code Types (not in ESP)

4-2

<P> <Q> <R> <S>

Result Decode Rate Test for Single Label Percentage Rate Test for Single Label Multilabel Decode Rate Test Multilabel Percentage Rate Test Extended Decode Rate Test for Single or Multilabel Exit any Rate Test Serial Trigger Character Enable Laser Scanning (Laser On) Disable Laser Scanning (Laser Off) Motor On Motor Off Relay-1 Pulse Relay-2 Pulse Noread Counter Noread Counter Reset Trigger Counter Trigger Counter Reset Match Code/Good Read Counter Match Code/Good Read Counter Reset Mismatch Counter Mismatch Counter Reset Enable Match Code Type Disable Match Code Type Store Next Label Scanned as Master Label Download Master Label Information Request Master Label Information Delete Master Label Information Software Reset (does not save for power-on) Software Reset/Restore Default Software Reset/Read NOVRAM Enter Configuration Mode Software Reset/Save Parameters for Power-on Restore/Save Default Configuration for Power-on Save Scanner Type, SPS, and Gain for Power-on Display Software Part Number Display Checksum of EPROM Show Scanner Status Show Software Status (Send Status Byte, Part Number, and ROM Checksum. Display Current NOVRAM Checksum and Display NOVRAM Checksum at Power Up,) Autodiscriminate All Codes Enable Code 39 Only Enable Codabar Only Enable I 2 of 5 Only

MS-810 Industrial Scanner User’s Manual

Page 85

Read Rate

Read Rate Decode (and percentage) rates can vary dramatically due to the angle and location of the label in relation to the scan beam (or scan line, if using a scan head with a moving beam). These tests are very useful in aligning and positioning the scanning device during installation.

Single Label Percent Test Clicking Single Label Percent and Start instructs the scanner to output the percent of decodes and any scanned label data. Associated serial command: <Cp>

Single Label Decodes/Second Test Clicking Single Label Decodes/Sec and Start instructs the scanner to output the decodes per second and label data (if any). The decode rate can vary dramatically due to the angle and location of the label in relation to the scan beam (or scan line, if using a scan head with a moving beam). This test is very useful in aligning and positioning the scanning device during installation. Associated serial command: <C>

Multi-label Percent Test

Associated serial command: <Cm>

Multi-label Decode Rate Test Clicking Multi-label Decode/Sec and Start instructs the scanner to output the decode rate and label data (if any) for multiple labels. Associated serial command: <Cs>

MS-810 Industrial Scanner User’s Manual

4-3

4–Utilities

Clicking Multi-label Percent and Start instructs the scanner to output the percentage of scans decoded and label data (if any) for multiple labels.

Page 86

Chapter 4 End Read Rate Test Clicking Stop ends both the Percent test and the Decodes/Second test for both single and multi-label. Associated serial command: <J>

Extended Mode Choosing any of the Read Rate modes along with Extended Mode affects both single and multiple labels. It instructs the scanner to output the transition data along with the data from the latest test command sent. For example, enabling extended mode along with single or multiple decodes per second will cause the decode rate, label data, and transition data to be displayed. Label Information

Reflectance Threshold

Decode Rate per Second

Number of Label Bar

347 Decodes/Sec 0071486026624 REF= 488 Decodes/Sec 0071486026624 REF= 488 Decodes/Sec 0071486026624 REF= 447 Decodes/Sec 0071486026624 REF=

0 TRANS= 38 0 TRANS= 37 0 TRANS= 37 0 TRANS= 33

* Example shows output when Postamble is enabled and defined as a carriage return and a line feed.

Associated serial command: <Ce> after <C>, <Cs>, <C>, or <Cs> Note: The <Ce> command has no immediate effect if not preceded by <C>, <Cs>,

4–Utilities

<C>, or <Cs>.

4-4

MS-810 Industrial Scanner User’s Manual

Page 87

Trigger

Trigger Clicking the Setup button will bring up the current trigger character. Next click Send to send the trigger character to the scanner and initiate a read cycle. The results, a good read or noread message, will be displayed on the blank screen below the button. Note: Your scanner must be in a point-to-point protocol for Trigger Setup to work. Note: You can define the trigger character in the Operations menu.

Associated serial command: <Ki serial trigger character>

4–Utilities

MS-810 Industrial Scanner User’s Manual

4-5

Page 88

Chapter 4

Scanner Enable Laser Scanning Clicking the Laser On button or sending serial command <H> will turn the laser on continuously. Note: Enable Laser Scanning does not relate to Laser On/Off command.

Associated serial command: <H>

Disable Laser Scanning Clicking Laser Off will turn the laser off. This feature is useful during extended periods of time when no bar code labels are being scanned or the scanner is being configured. Disabling laser scanning will not affect any downloaded commands to the scanner. Note: Disable Laser Scanning does not relate to Laser On/Off command.

Associated serial command: <I>

Motor On Clicking Motor On or sending serial command <KE> turns the spinning mirror and raster mirror motors on (if not already running). Note: Spinning mirror reaches full speed after a short time delay.

4–Utilities

Associated serial command: <KE>

Motor Off Clicking Motor Off or sending serial command <KF> turns the spinning mirror motor off. This command is useful for long idle periods. Associated serial command: <KF>

Output-1 Clicking Output #1 activates the output between pin 7 (regardless of Master Label or Output-1 Driver status). Associated serial command: <L1>

4-6

MS-810 Industrial Scanner User’s Manual

Page 89

Counters

Counters Counter commands can be a numeric value from 00000 to 65,535. After reaching the maximum numeric limit of 65,535, an error message will be displayed and the counter will automatically rollover and start counting again at 00000. To obtain the cumulative total of counts after the rollover has occurred, add 65,536 per each rollover (the scanner does not keep track of the number of rollovers) to the current count. Note: All counter values will be lost if power is recycled to the scanner or the scanner receives a reset or save command.

Clicking Reset for any counter will reset that counter to 0. Clicking Request for any counter will return the current number for that counter.

Noread Counter Clicking Request displays the total number of noreads that have occurred since the last reset. Associated serial command: <N>

Noread Counter Reset Clicking Reset sets Noread Counter to 00000. Associated serial command: <O>

Trigger Counter 4–Utilities

Clicking Request displays the total number of triggers since the last reset. Associated serial command: <T>

Trigger Counter Reset Clicking Reset sets the trigger counter to 00000. Associated serial command: <U>

Match Counter (or Good Read Counter) Clicking Request displays the total number of good reads matching the master label or, if Master Label is not enabled, the number of good reads since the last reset. This MS-810 Industrial Scanner User’s Manual

4-7

Page 90

Chapter 4 counter is always enabled, but will only work as a match count when Master Label is enabled. If Master Label is not enabled, this counter records the number of good reads. This count can be requested at any time. Associated serial command: <V>

Match Counter Reset Clicking Reset sets the Match Counter to 00000. Associated serial command: <W>

Mismatch Counter Clicking Request displays the message the number of labels successfully read that do not match the master label since the last reset. Associated serial command: <X>

Mismatch Counter Reset Clicking Reset sets the Mismatch Counter to zero.

4–Utilities

Associated serial command: <Y>

4-8

MS-810 Industrial Scanner User’s Manual