Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 10 of 15

MS-810 Industrial Scanner User's Manual, pages 91 to 100

Pages 91 to 100 of 144

The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-810

Page 91

Master Label

Master Label Enable Match Code Type Identical to “Match Code Type,” on page 2-22. Instructs the scanner to compare bar code labels being scanned with a master label and may under certain conditions send out a relay driver signal and update internal counters. If no master label has been entered, every decoded label will be a “mismatch” and will increment the mismatch counter by one. Enable Match Code Type is intended for use when the scanner is in a triggered mode. If the Match Code Type is enabled in the Continuous Read mode, the scanner defaults to Continuous Read 1 Output mode, and the label data must change before the scanner will output data again, unless a timeout, if enabled, occurs. (See “Operation Menu” on page 2-16.) Associated serial commands: <E>

Disable Match Code Type Disables Match Code Type. Associated serial commands: <F>

Store Next Label Scanned as Master Label

Associated serial commands: <G>

Download Master Label Information Downloads master label information into RAM from the host or a terminal. A stored master label will not affect standard operation unless Match Code Type is enabled. The Xs denote alphanumeric data, from 1 to 64 characters. Associated serial commands: <)XXXX)>

MS-810 Industrial Scanner User’s Manual

4-9

4–Utilities

If Match Code has been enabled, causes the scanner to read the next bar code label scanned as the master label and stores it in RAM. All subsequently decoded labels are compared against the new master label information. (See “Match Code Type” on page 2-22.)

Page 92

Chapter 4 Request Master Label Information Immediately sends the master label information to the host. To prevent conflicts with outputting label data, first send the <I> command (Disable Laser Scanning (Laser Off)). Associated serial commands: <)>

Delete Master Label Information Deletes master label information that has previously been loaded by either <)XXXX)> Download Master Label Information Command or <G> Store Next Label as Master Label command.

4–Utilities

Associated serial commands: <))>

4-10

MS-810 Industrial Scanner User’s Manual

Page 93

Reset

Reset Important: All <A> and <Z> commands must be followed by a one second delay before any operations, commands, or reads can be processed.

Reset Initializes all serial configuration commands in RAM and resets all counters and operating parameters. Note: Software Reset will reset all counters. You should record all data that you wish to save prior to sending this command.

<A>

Initialize RAM

NOVRAM

ROM

Associated serial command: <A>

Reset/Restore Default Restores the ROM default values to RAM then initializes them. Does not effect Scanner Type, Scans per Second, or Gain Adjustment.

<Ad>

Initialize RAM

Associated serial command: <Ad> NOVRAM

ROM

Reset/Read NOVRAM <An>

Associated serial command: <An>

Initialize

4–Utilities

Reads the NOVRAM settings then initializes them to RAM.

RAM NOVRAM

MS-810 Industrial Scanner User’s Manual

ROM

4-11

Page 94

Chapter 4 Reset/Save Parameters for Power-on Allows you to save all configuration command settings to NOVRAM. Numeric counter values and master label data are not saved by this command.1 Associated serial command: <Z>

Restore/Save Default Configuration for Power-on Allows you to restore and save default settings for all but Scanner Type, Scans per Second, and Gain Adjustment to NOVRAM.

<Zd

RAM ROM

NOVRAM

Note: Power must be available to the scanner during the default procedure.

Defaulting might be necessary after temporary changes or if communications between the scanner and another device are lost or interrupted, or if you are using incompatible equipment (for example, a terminal is set to communicate at 9600 baud, but the scanner is configured at 38.4K baud). Associated serial command: <Zd>

Save Scanner Type, SPS, and Gain for Power-on

4–Utilities

Allows you to save the current settings for Scanner Type,2 Scans per Second, and Gain Adjustment to NOVRAM. Once you send this command, default values can only be recalled if you reenter them individually and then save them again with this command.

<Zp NOVRAM

RAM ROM

Important: This command will replace the optimized factory setting for Gain Adjustment with your new setting; record and save this setting for future reference prior to sending this command. Associated serial command: <Zp>

1. The <Z> Software Reset/Save Parameters for Power-on command can be executed at least 10,000 times. In normal usage this will exceed the life of the scanner. If frequent changes to the operating parameters are required, it is recommended that the <Z> command be used only when the current configuration has been changed and the changes are to be permanent. 2. Scanner Type should not be changed from its factory setting.

4-12

MS-810 Industrial Scanner User’s Manual

Page 95

Checksum

Checksum Part Number Displays software part number. Associated serial command: <#>

Checksum Displays a four-digit hex number (corresponding to a given firmware version) used to verify a scanner’s EPROM. Associated serial command: <!>

Show Scanner Status Used to display certain operating parameters (NOVRAM, command, and operation status). After sending this command, the scanner immediately responds with <X>, where “X” is an ASCII character between @ and ∆ on the ASCII table. Associated serial command: <?> To interpret the scanner’s status, 1. Look up the ASCII character’s Hex value in the ASCII table on page A-10.

2. Refer to table 4-3 to find the Hex value’s binary conversion. The binary bit digits for “4” equal 0100; the binary bit digits for “D” equal 1101. Hence, the binary conversion of 4D is 01001101.

MS-810 Industrial Scanner User’s Manual

Hex Value Digits

Binary Bit Digits 7 6 5 4 3 2 1 0

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1

0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1

0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1

0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1

4-13

4–Utilities

For example, the scanner responds with an <M>, corresponding Hex value is 4D.

Table 4-3 Hex Value to Binary Conversion

Page 96

Chapter 4 3.Compare bit digits with the “Is Status Active?” row in table 4-4 (each bit has a specific meaning) Table 4-4 Finding Scanner Status from Binary Bit Digits 0 1 0 0 1 1 0 1 Bit Location: 7 6 5 4 3 2 1 0 NOVRAM error detectora

Communication error detected

Command received

Command error detected

No =

Motor is spinning; scanner is ready

Is Status Yes = Active?

Scanner is in a read cycle

Scanner Status:

Always set to 1

Binary Code

0 = even Parity 1 = odd

In the example shown in table 4-4, a scanner status request returns an <M> corresponding to 4D hex or 01001101. This means that the scanner’s status is even parity, (skip bit location 6; it will always equal 1), with the scanner not in a read cycle, with the motor spinning and the scanner ready to read, with no NOVRAM error detected, with a communications error detected, with the command not received, and with a

N/A

1

0

0

1

1

1

N/A

0

1

1

0

0

0 a. NOVRAM status is valid only after the first status request following a NOVRAM read or write.

If you send the <?>

The scanner will report:

After Power-on Whether the (NOVRAM NOVRAM was Read) read correctly the first time the status command was received.

4–Utilities

After Sending a Command

Whether the command was sent correctly.

After NOVRAM Whether the Write NOVRAM was written correctly.

For example: With the scanner in a triggered mode without a serial or edge trigger present, power–off, then power–on and enter the <?> command. The scanner responds with <@> for a good load or <H> for a bad load. See “NOVRAM error detected” in table 4-4 on page 4-14. With the scanner in a triggered mode without a serial or edge trigger present, enter the <?> command to clear the error flags. Then enter the desired command, <L1> for example. Enter <?> again. The scanner responds with <B> if the command was received, <C> if there was an error in the command, or <F> if there was a serial data error. The scanner responds in the same manner as after power– on (NOVRAM read).

Show Software Status Sends the following in this order: status byte, part number, ROM checksum for both possible lengths of ROM (1 megabyte and 512 bytes), current NOVRAM checksum, and NOVRAM checksum at power up. Associated serial command: <?1>

4-14

MS-810 Industrial Scanner User’s Manual

Page 97

Code Type Commands

Code Type Commands (Not in the Utilities Menus.)

Autodiscriminate All Codes Enables the scanner to decode all available bar code types without changing scanner configuration settings. Note: For maximum scanning speed, enable only those bar code symbologies used in the application.

Associated serial command: <P>

Code 39 Only Allows only Code 39 labels to be read. Associated serial command: <Q>

Codabar Only Allows only Codabar labels to be read. Associated serial command: <R>

I 2 of 5 Only 4–Utilities

Allows only Interleaved 2 of 5 labels to be read. Associated serial command: <S>

MS-810 Industrial Scanner User’s Manual

4-15

Page 98

4–Utilities

Chapter 4

4-16

MS-810 Industrial Scanner User’s Manual

Page 99

Appendices

Contents Appendix A, Scanner Specifications ............................................... A-2 Appendix B, Electrical Specifications .............................................. A-4 Appendix C, Ground and Shield Considerations ..................................A-9 Appendix D, ASCII Table .............................................................. A-10 Appendix E, Transferring/Restoring Files ..................................... A-11 Appendix F, IB-130 Interface Module ........................................... A-13 Appendix G, Number of Scans ..................................................... A-18 Appendix H, Special 5 VDC MS-810 ............................................ A-21 Appendix I, Using the IB-105 ........................................................ A-22 Appendix J, Troubleshooting ........................................................ A-28 Appendix K, Bar Code Symbology ............................................... A-31 Appendix L, Interface Standards .................................................. A-32 Appendix M, Multidrop Communications ............................................A-33 Appendix N, Glossary of Terms .................................................... A-36

Appendices

MS-810 Industrial Scanner User’s Manual

A-1

Page 100

Appendix A, Scanner Specifications Mechanical Parameters

Light Source

Length: 3.47” (8.81 cm)Width: 2.59” (6.58 cm)

Type: Laser Diode

Height: 1.38” (3.50 cm)Weight: 7.5 oz. (212 g)

Output Wavelength: 670 nm nominal Safety Class: CDRH Class II

Back

Operating Life: 50,000 hours @25°C (10,000 hours @50°C)

.93" (2.36 cm)

Laser Cooling: Thermostatically-controlled thermocooler

.54" (1.37 cm)

Scanning Parameters

M4 x 0.7 x 4.57 mm deep Mounting holes (2 places)

1,10" (2.79 cm)

Primary Mirror Type: Rotating, 10-faceted Scan Rate: 300 to 800 scans per second; default is 400.

Top

Scan Width Angle: Typically 60° Pitch: ±50° maximum .53" (1.35 cm)

Skew: ±40° maximum

2.40" (6.10 cm)

Label Contrast: 25% min. absolute dark to light differential at 670 nm wavelength

Front

1.38" (3.50 cm)

Optional Raster Mirror Image: 10 raster scan lines over a 2-degree arc

3.47" (8.81 cm)

Side 1.10" (2.7 cm) 2.59" (6.58 cm)

.62" (1.57 cm)

0.17 inch (4.32 mm)

6 inches (152.4 mm)

0.24 inch (6.1 mm)

8 inches (203.2 mm)

0.31 inch (7.87 mm)

10 inches (254 mm)

0.38 inch (9.65 mm)

Baud Rates: 300, 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K, 76.8K M4 x 0.7 x 3.8 mm deep Mounting holes (2 places)

2.59" (6.58 cm)

Parity: Odd, Even, None Stop Bits: 1, 2Data Bits: 7, 8

Protocols

Bottom

Appendices

4 inches (101.6 mm)

Interface: RS-232 standard; also available: RS-422/485, *DeviceNet, *SDS, *Profibus DP, *Ethernet

2.50" (6.35 cm)

Figure A-1 MS-810 Dimensions

A-2

Raster Height 0.10 inch (2.54 mm)

Communications

.54" (1.37cm)

1.40" (3.56 cm)

Scan Range 2 inches (50.8 mm)

Point-to-Point, Point-to-Point w/RTS/CTS, Point-toPoint w/XON/XOFF, Point-to-Point w/RTS/CTS & XON/XOFF, Polling Mode D, Multidrop, User Defined, User Defined Multidrop.

MS-810 Industrial Scanner User’s Manual