For the Microscan MS-810
Page 101
Scanner Specifications Code Types
Status Lights
Standard codes: Code 39, Codabar, Interleaved 2 of 5, UPC/EAN, Code 128
LED
Other codes: Code 16K, UCC/EAN-128, Code 49, Code 93, DX Code, EDP & STK/EDP, MSI Code, Pharma Code, Plessey Code
Power
Red
Ready
Green
Scanner is ready to read
Good Read
Green
Label is qualified as good
Environment Enclosure: Die-cast aluminum, IP65 rated
Luminance
Status 5V power is present
FIS Options
Operating Temperature (inside ambient): 32° to 122°F (0° to 50°C) Storage Temperature: –20° to 158°F (–29° to 70°C) Humidity: Up to 90% (non-condensing) Ambient Light Immunity: • 450 foot candles (indoor: fluorescent, incandescent, mercury vapor, sodium vapor) • 1800 foot candles (soft outdoors)
Read Ranges The table and graphs that follow show scan widths and read range minimum and maximums for several bar code densities.
Table A-1 Range Data1
Each MS-810 model is identified by an FIS (final instruction sheet) number that refer to a set of options. The following are the standard options available at this time:
Table A-2 FIS Options FIS #
Protocol
Density
Line
Voltage
009
232
Standard Density
Single Line
10-28
010
232
Standard Density
Raster Line
10-28
011
232
High Density
Single Line
10-28
012
232
High Density
Raster Line
10-28
013
422/485
Standard Density
Single Line
10-28
014
422/485
Standard Density
Raster Line
10-28
Single Line
10-28
High Density
Medium Density
Low Density
.005" (.127 mm)
1.2"to 2.75" (3.05 to 6.99 cm), - .007" (.178 mm)
1.2"to 3.8" (3.05 to 9.65 cm)
2"to 5.2" (5.08 to 13.21 cm), 015
422485
High Density
.010" (.254 mm), 1.5"to 7" (3.81 to 17.78 cm)
4" to 10" (10.16 to 25.4 cm)
016
422/485
High Density
Raster Line
10-28
4" to 16" (10.16 to 40.64 cm)
017
422/485
Standard Density
Single Line
10-28, 1.5"to 8.5" (3.81 to 21.59 cm)
018
232
Standard Density
Raster Line
10-28
.020" (.508 mm), 1.5"to 11" (3.81 to 27.94 cm)
4" to 20" (10.16 to 50.80 cm)
019
232
Low Density
Single Line
10-28
.030" (.762 mm), 1"to 12" (2.54 to 30.48 cm)
4" to 25" (10.16 to 63.50 cm)
.040" (1.02 mm), - 4" to 30" (10.16 to 76.20 cm)
.015" (.381 mm)
1. At 400 decodes per second using Code 39 grade A label.
MS-810 Industrial Scanner User’s Manual
A-3
Appendices
Narrowbar-width
Page 102
Chapter A
Appendix B, Electrical Specifications Power Supply Requirements: 10–28 VDC, 200 mV p-p max. ripple, 2.7 watts rated 24 VDC (standard); also available: +5V ±4% regulated @ 480 mA with 200 mV p-p max. ripple. Table A-3 10 to 28 VDC Pinouts for Standard Options Pin #
Function
Pin #
Function
1
+10–28 VDC (in)
9
Trigger input (+)
2
RS-232 TXD/RS-422 TXD (–)
10
CTS (in)/RS-422 RXD (+)
3
RS-232 RXD/RS-422 RXD (–)
11
Output 1 (–)
4
Signal ground (RS-232)
12
New master
5
Output 2 (–)
13
Chassis ground
6
RTS (out)/RS-422 TXD (+)
14
Output 2 (+)
7
Output 1 (+)
15
Trigger input (–)
8
Default configuration (in)
6
11
1
5
10
15
Figure A-2 15-pin High-density D-subminiature plug
Discrete I/O Trigger Input: Opto-isolated, 5–28V rated, (12 mA @ 24 VDC)
Appendices
Outputs (1&2): Opto-isolated, 1–28V rated, (I CE <100 mA @ 24 VDC, current limited by user)
Optoisolator Connection Diagrams for 10-28 Volt With the MS-810 scanner’s optoisolator, input and output signals can be isolated from the scanner’s internal circuitry. Please carefully observe the following schematics and their indicated current limitations before connecting to power. CAUTION: The user must limit the maximum current through the optoisolator to 100 mA.
A-4
MS-810 Industrial Scanner User’s Manual
Page 103
Electrical Specifications Sample Output Application Diagrams: Generic Outputs
W aveform Characteristics:
MS-810
I load =5mA I load =50mA I load =100mA
LOAD Pin 7/14
+ -
VOUT
Iload
Pin 11/15
V OUT-ON : 0.75 V
1.0 V
1.2 V t ON-TYP : 15 µS
20 µS
30 µS t OFF-TYP : 1000 µS
100 µS
50 µS
Isolated
LOAD V
LOAD
MS-810
(Load)
Pin 7 & 14 (+ outputs 1 & 2)
(Load Signal) Pin 11 & 5 (- outputs 1 & 2)
LOAD
MS-810
V
Pin 7 & 14 (+ outputs 1 & 2)
LOAD
Pin 11 & 5 (- outputs 1 & 2)
(Load Signal) (Load)
Non-Isolated
LOAD
MS-810 Pin 1 (+10-28V)
V10-28V (Load)
Pin 7 & 14 (+ outputs 1 & 2)
(Load Signal) Pin 11 & 5 (- outputs 1 & 2)
Pin 4 (GND)
LOAD
MS-810 Pin 1 (+10-28V)
V10-28V
Appendices
Pin 7 & 14 (+ outputs 1 & 2)
(Load Signal) Pin 11 & 5 (- outputs 1 & 2)
(Load)
Pin 4 (GND)
MS-810 Industrial Scanner User’s Manual
A-5
Page 104
Chapter A More Sample Output Application Diagrams LOAD VRELAY MS-810
Isolated SECONDARY RELAY or ACTIVATION CIRCUIT. (Non-isolated application would connect MS-810 and LOAD Power and/or GND.)
Pin 1 (+10-28V) Pin 7 & 14 (+ outputs 1 & 2) Pin 11 & 5 (- outputs 1 & 2) Pin 4 (GND)
MS-810 Pin 1 (+10-28V)
LOAD VRELAY
Pin 7 & 14 (+ outputs 1 & 2)
(Non-isolated application would connect MS-810 and LOAD Power and/or GND.)
Pin 11 & 5 (- outputs 1 & 2) Pin 4 (GND)
LOAD
MS-810
Isolated SECONDARY RELAY or ACTIVATION circuit.
Isolated PLC or LOGIC circuit. VPLC
Pin 1 (+10-28V) Pin 7 & 14 (+ outputs 1 & 2)
Input
PLC
Pin 11 & 5 (- outputs 1 & 2)
(Non-isolated application would connect MS-810 and LOAD Power and/or GND.)
GND
Pin 4 (GND)
MS-810
LOAD Pin 1 (+10-28V) Pin 7 & 14 (+ outputs 1 & 2)
Appendices
Pin 11 & 5 (- outputs 1 & 2)
Isolated PLC or LOGIC circuit.
VPLC Vdd
PLC
(Non-isolated application would connect MS-810 and LOAD Power and/or GND.)
Input
Pin 4 (GND)
A-6
MS-810 Industrial Scanner User’s Manual
Page 105
Electrical Specifications Sample Input Application Diagrams: Generic Input for Trigger SOU RCE
M S-810 Pin 9 (trigger+)
+ –
VO UT
I load
Pin 15 (trigger-)
Waveform Characteristics: Minimum Maximum VIN-HIGH/ IIN-HIGH : 4.8V / 2 mA 28V / 15 mA VIN-LOW / IIN-LOW : 0V / 0mA 1.5 V / 2.8 mA Minimum Input Pulse Width: 60 µS Max Frequency (50% duty cycle): 16.7 kHz
Isolated (trigger only) SOURCE
MS-810 Pin 9 (trigger+)
VSOURCE
SOURCE configured to "SINK" activation current. Shows optional PULL-UP resistor.
Pin 15 (trigger-)
Source Signal
SOURCE VS OURCE MS-810 Pin 9 (trigger+)
Source Signal
SOURCE configured to "SOURCE" activation current. Shows optional PULL-DOWN resistor.
Pin 15 (trigger-)
Non-Isolated SOURCE
MS-810 Pin 1 (+10-28V)
V10-28V
Pin 9 (trigger+)
SOURCE configured to "SINK" activation current. Shows optional PULL-UP resistor.
Pin 15 (trigger–) Pin 4 (GND)
Source Signal SOURCE
Pin 1 (+10-28V)
V10-28V Source Signal
SOURCE configured to "SOURCE" activation current. Shows optional PULL-DOWN resistor.
Appendices
Pin 9 (trigger+)
Pin 15 (trigger–) Pin 4 (GND)
MS-810 Industrial Scanner User’s Manual
A-7
Page 106
Chapter A More Sample Input Application Diagrams SOURCE MS-810 Pin 9 (trigger+)
TRIG
PLC
Pin 15 (trigger-)
Isolated PLC configured to "SOURCE" TRIGGER current. (Output must be capable of supplying required Voltage/ Current.)
GND
SOURCE MS-810 Pin 9 (trigger+)
Vdd
PLC
Isolated PLC configured to "SINK" TRIGGER current. (Output must be capable of sinking required Voltage/ Current.)
TRIG
Appendices
Pin 15 (trigger-)
+24V
A-8
MS-810 Industrial Scanner User’s Manual
Page 107
Ground and Shield Considerations
Appendix C, Ground and Shield Considerations
COM
I/O < Control Signal >
Signal
VIN +
Scanner
Scanner
Ground loops, signal degradation due to different ground potentials in communicating devices, can be eliminated or minimized by ensuring that both the host, scanner, and their power supplies are connected to a common earth ground.
DC Source
Chassis
VIN +
Ground Loops
+ –
+ –
DC Source
+ –
DC Source
RX– RX+ TX– TX+
RS-232 signals have a common signal ground (pin 4). Pin 4 is normally connected to pin 13 (chassis ground) in the scanner; however, under certain conditions (e.g., when potential differences exist between power outlet grounds) signal and chassis grounds can be isolated from each other inside the scanner by Microscan technicians.
VIN +
Host
RX– RX+ TX– TX+
Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.
Figure A-3 Grounding Diagram, Scanner-Host
Appendices
MS-810 Industrial Scanner User’s Manual
A-9
Page 108
Chapter A
Appendix D, ASCII Table
Appendices
Table A-4 ASCII Table with Control Characters
A-10
Dec
Hex
Mne
Ctrl
Dec
Hex
Ch
Dec
Hex
Ch
Dec
Hex
Ch
00
00
NUL
^@
32
20
SP
64
40
@
96
60
`
01
01
SOH
^A
33
21
!
65
41
A
97
61 a
02
02
STX
^B
34
22
"
66
42
B
98
62 b
03
03
ETX
^C
35
23
#
67
43
C
99
63 c
04
04
EOT
^D
36
24
$
68
44
D
100
64 d
05
05
ENQ
^E
37
25
%
69
45
E
101
65 e
06
06
ACK
^F
38
26
&
70
46
F
102
66 f
07
07
BEL
^G
39
27
'
71
47
G
103
67 g
08
08
BS
^H
40
28
(
72
48
H
104
68 h
09
09
HT
^I
41
29
)
73
49
I
105
69 i
10
0A
LF
^J
42
2A
*
74
4A
J
106
6A j
11
0B
VT
^K
43
2B
+
75
4B
K
107
6B k
12
0C
FF
^L
44
2C
,
76
4C
L
108
6C l
13
0D
CR
^M
45
2D
-
77
4D
M
109
6D m
14
0E
SO
^N
46
2E
.
78
4E
N
110
6E n
15
0F
SI
^O
47
2F
/
79
4F
O
111
6F o
16
10
DLE
^P
48
30
0
80
50
P
112
70 p
17
11
DC1
^Q
49
31
1
81
51
Q
113
71 q
18
12
DC2
^R
50
32
2
82
52
R
114
72 r
19
13
DC3
^S
51
33
3
83
53
S
115
73 s
20
14
DC4
^T
52
34
4
84
54
T
116
74 t
21
15
NAK
^U
53
35
5
85
55
U
117
75 u
22
16
SYN
^V
54
36
6
86
56
V
118
76 v
23
17
ETB
^W
55
37
7
87
57
W
119
77 w
24
18
CAN
^X
56
38
8
88
58
X
120
78 x
25
19
EM
^Y
57
39
9
89
59
Y
121
79 y
26
1A
SUB
^Z
58
3A
:
90
5A
Z
122
7A z
27
1B
ESC
^[
59
3B
;
91
5B
[
123
7B
{
28
1C
FS
^\
60
3C
<
92
5C
\
124
7C
|
29
1D
GS
^]
61
3D
=
93
5D
]
125
7D
}
30
1E
RS
^^
62
3E
>
94
5E
^
126
7E
~
31
1F
US
^_
63
3F
?
95
5F
_
127
7F
D
MS-810 Industrial Scanner User’s Manual
Page 109
Transferring/Restoring Files
Appendix E, Transferring/Restoring Files The MS-810 ESP offers a variety of options for receiving, saving, and defaulting configuration files.
Receiving Settings from the MS-810 If you want your host computer to receive the current settings from the MS-810, click RECEIVE FROM SCANNER. Note: If receiving scan data and you are in Continuous Read, symbols being scanned may interfere with your data request.
from a File If you want to load the settings from a saved settings file to your host computer, open the desired file and then click SEND/NO SAVE and follow this with RECEIVE FROM SCANNER. (Clicking RECEIVE FROM SCANNER in this context ensures that the scanner’s current settings will appear in your host settings list.)
Saving Current Configuration to the MS-810 Click Apply in the current menu page. Note: Clicking OK on these menu pages will only update the items in the Current Settings window. From within the SEND/RECV box, click SEND/NO SAVE to initialize settings and reset counters only, or click SEND/SAVE to initialize, reset counters, and save these settings to the MS-810’s memory for power up.
Saving Current Configuration to File You can save a file by clicking SAVE AS (or SAVE) from the File pull-down menu. The settings are saved only on the computer’s hard drive or other storage media. This is particularly useful for backing up files or for configuring multiple configurations.
Creating a New Configuration File
You can also load, edit, and save an existing configuration file.
MS-810 Industrial Scanner User’s Manual
A-11
Appendices
To create a new file of configuration settings, first be sure you’ve saved the current configuration file to the computer’s hard drive or other storage media. Next pull down the File menu in the ESP™ and select New. A new Untitled window will open with a listing of the factory default settings. Change these settings to suit your requirements and save this file to the computer’s hard drive under a new name.
Page 110
Chapter A Restoring Factory Default Settings Note: Be certain that you’ve saved any other configuration files to the host computer that you may want to reload later.
Defaulting by Menu or Serial Commands Default settings can be reset for individual menu pages or for all menus at once. To restore factory defaults for individual menus (Communications, Operations, Code Types, Output, or Setup): Click the DEFAULT button on the specific menu. Click SEND/NO SAVE, and then RECEIVE FROM SCANNER (to see current settings). To restore factory defaults for ALL menus, select the DEFAULT button on the Reset dialog in the Utilities menu or send a <Ad> serial command.
Defaulting by New Close and save your current file. Select New in the File pull-down menu. The resulting File will have your original factory default settings. Give it a new name and save to it as you make changes. Click SEND/NO SAVE, and then RECEIVE FROM SCANNER.
Defaulting by Hardware Reset (shorting Pins 4 and 8) If a software default reset is not possible, it may be necessary to resort to a Hardware default. To do this you must first expose wires that have continuity to pins 4 and 8. You cannot directly short pins 4 and 8 because power must be applied to the scanner. 1. Apply power to the scanner. 2. Expose wires or pins that have continuity to pins 4 and 8 respectively. Caution: Be certain that the correct pins are shorted. Shorting the wrong pins can cause serious damage to the unit. 3. Momentarily short these wires and listen for a series of short beeps.
Appendices
4. Within 3 seconds, short them again. A longer beep should be heard. If not, repeat the process.
A-12
MS-810 Industrial Scanner User’s Manual