The text of a manual · part 8 of 15
MS-810 Industrial Scanner User's Manual, pages 71 to 80
Pages 71 to 80 of 144
The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-810
Page 71
Protocol Commands Format: <Kcstatus> status: 0 = Disabled 1 = Enabled Example: To enable LRC, send <Kc1>.
3–Serial Config.
MS-810 Industrial Scanner User’s Manual
3-9
Page 72
Chapter 3 Response Timeout Format: <KAtimeout setting>1 timeout setting: Default is 12 (ms). Any number from 0 to 65,000 (a zero causes an indefinite wait). Example: To change Response Timeout to 30 ms, send <KA30>.
Intercharacter Delay Format: <KBtime interval> time interval (between characters in milliseconds): Default is 0. Any number from 0 to 255.
3–Serial Config.
Example: To change Inter-character Delay to 30 ms, send <KB30>.
1. For use with Microscan’s IB-105.
3-10
MS-810 Industrial Scanner User’s Manual
Page 73
Operation Commands
Operation Commands Triggering Mode Format: <Kgtriggering mode,filter time> trigger filter time (in 128 µs triggering mode: increments): 0 = Continuous Read Default is 78 (9984 µs; approx. 10 1 = Continuous Read 1 Output ms) 2 = External Level Any number between 2 and 255. 3 = External Edge 4 = Serial Data 5 = Serial Data & Edge Example: To select External Edge, send <Kg3>.
End of Read Cycle
3–Serial Config.
Format: <Khend of read cycle mode,timeout> end of read cycle mode: 0 = Timeout 1 = New Trigger 2 = Timeout & New Trigger timeout (in 10 millisecond increments): Default is 100 (one second). Any number between 0 and 65535.
Example: To select Timeout and change the timeout value to 6 seconds, send <Kh0,600>.
Serial Trigger Character Format: <Kiserial trigger character>1 serial trigger character: Default is ^]. Any available ASCII character (see “ASCII Table with Control Characters” on page A-10). Example: To define the Serial Trigger Character as a lowercase c, send <Kic>.
1. Avoid selecting a serial trigger character that is also an operational command. For example, an uppercase C cannot be used as a serial trigger character because it is the operational command for Enter Decode Rate Test. However, a lowercase c could be used without initiating the decode rate test. MS-810 Industrial Scanner User’s Manual
3-11
Page 74
Chapter 3 External Trigger Level Format: <Kjexternal trigger level> external trigger level (initiates a read cycle): 0 = Negative 1 = Positive Example: To change External Trigger Level to Negative, send <Kj0>.
Good Decode Reads Format: <Kmnumber of reads> number of reads (before a good decode): Default is 1. Any number from 1 to 31.
3–Serial Config.
Example: To change Good Decode Reads to 3, send <Km3>.
Match Code Type Format: <Kntype,sequential matching,match start position,match length,wild card character,sequence on noread,sequence on every mismatch> type: 0 = Disabled 1 = Enabled 2 = Sequential 3 = Wild Card sequential matching 0 = Increment 1 = Decrement match length Default is 1. 1 to 31 wild card character Default is *. Any ASCII character.
match start position Default is 0. 0 to 64 sequence on noread: 0 = Disabled 1 = Enabled When enabled, the scanner sequences (increment or decrement) on every noread.
If 001, 002, noread, then search for 003. If 001, 002, noread, then search for 004.
sequence on every mismatch: 0 = Disabled 1 = Enabled When disabled, if a mismatch is out of sequence by no more than 1, then the sequence resumes and searches indefinitely. When enabled, the scanner sequences on every mismatch.
If 001, 002, 004 (mismatch), then search for 005. If 001, 002, mismatch, then search for 004. If mismatch occurs again, then search for 005, etc.
3-12
MS-810 Industrial Scanner User’s Manual
Page 75
Operation Commands Example: To enable Match Code Type for Sequential, set Sequential Matching for Decrement, and enable Sequence on Every Mismatch, send <Kn2,1,,,,,1>.
New Master Pin Format: <Kzstatus> status: 0 = Disabled 1 = Enabled Example: To enable New Master Pin, send <Kz1>.
Number of Labels Format: <KLnumber,multilabel separator> number of labels: Default is 1. Any number from 1 to 6 multilabel separator: Default is ,. Any valid ASCII character
3–Serial Config.
Example: To change Number of Labels to 3, send <KL3>.
Operations Status Request Format: <KV?> Returns status of each command in the group.
MS-810 Industrial Scanner User’s Manual
3-13
Page 76
Chapter 3
Code Type Commands Code 39 Format: <Kpstatus,check digit status,check digit output status,large intercharacter gap,fixed code length status,code length> status: 0 = Disabled 1 = Enabled check digit status: 0 = Disabled 1 = Enabled check digit output status: 0 = Disabled 1 = Enabled large inter-character gap: 0 = Disabled 1 = Enabled fixed code length status: 0 = Disabled 1 = Enabled code length: Default is 10. Any number from 1 to 64.
3–Serial Config.
Example: To set Fixed Code Length to 30, send <K,,,,1,30> or <Kp1,0,0,0,1,30>.
Codabar Format: <Kqstatus,start & stop match status,start & stop output status,large intercharacter gap,fixed code length status,code length,check digit type,check digit output> status: 0 = Disabled 1 = Enabled start & stop match status: 0 = Disabled 1 = Enabled large inter-character gap: fixed code length status: 0 = Disabled 1 = Enabled check digit type: 0 = Disabled 1 = Mod 16 start & stop output status: 0 = Disabled 1 = Enabled
0 = Disabled 1 = Enabled code length: Default is 10 Any number from 1 to 64.
2 = NW7 3 = Both check digit output: 0 = Disabled 1 = Enabled
Example: To set Fixed Code Length to 9, send <Kq1,,,,1,9> or <Kq1,1,1,0,1,9>.
3-14
MS-810 Industrial Scanner User’s Manual
Page 77
Code Type Commands I 2 of 5 Format: <Krstatus,check digit status,check digit output status,code length #1,code length #2> status: 0 = Disabled 1 = Enabled check digit status: 0 = Disabled 1 = Enabled check digit output status: 0 = Disabled 1 = Enabled code length #2: code length #1: Default is 6. Default is 10. Zero or any even Zero or any even number from 2 to 64. number from 2 to 64. Example: To set Fixed Code Length #1 to 8 and Fixed Code Length #2 to 4, send <Kr1,,,8,4> or <Kr1,0,0,8,4>.
UPC/EAN
UPC status: 0 = Disabled 1 = Enabled
EAN status: 0 = Disabled 1 = Enabled (UPC must also be enabled)
separator status: 0 = Disabled 1 = Enabled separator character: Any ASCII character (except NUL). Default is a comma (,).
3–Serial Config.
Format: <KsUPC status,EAN status,supplementals status,separator status,separator character> supplementals status: 0 = Disabled 1 = Enabled 2 = Required
Example: To change Supplementals to Required, and change Separator Character to a dash (–), send <Ks1,1,2,1,–>.
Code 128 Format: <Ktstatus,fixed code length status,code length> status: fixed code length status: code length: 0 = Disabled 0 = Disabled Default is 10. 1 = Enabled 1 = Enabled Any number from 1 to 64. Example: To enable Code 128, enable Fixed Code Length, and set Code Length to 9, send <Kt1,1,9>.
MS-810 Industrial Scanner User’s Manual
3-15
Page 78
Chapter 3 Background Color Format: <Kxstatus> status: 0 = White 1 = Black Example: To enable Black for background, send <Kx1>. White is the default background on bar code symbols.
Narrow Margins/Symbology ID Format: <Konarrow margins status,symbology ID status> narrow margins status: 0 = Disabled 1 = Enabled symbology ID status: 0 = Disabled 1 = Enabled
3–Serial Config.
Example: To enable Narrow Margins, send <Ko1>.
Autodiscriminate Format: <P> Enables all available symbology types and disables OMR. You may individually disable/ enable each symbology type also. Note: For maximum scanning speed, enable only those symbologies used in the application.
Code Types Status Request Format: <KW?> Example: Returns status of each command in the group
3-16
MS-810 Industrial Scanner User’s Manual
Page 79
Output Commands
Output Commands Relay-1 Format: <Kvoutput on,polarity,pulse width,# before output> output on (mode): 0 = Mismatch or Noread 1 = Match (or Good Read) 2 = Mismatch 3 = Noread polarity: pulse width: 0 = Negative Default is 5 (50 ms). 1 = Positive 0 to 255
# before output: Default is 1. 1 to 255
Example: To set Relay-1 to Mismatch and change Pulse Width to 40 ms, and # Before Output to 5, send <Kv2,0,4,5> or <Kv2,,4,5>.
Relay-2 Format: <Kwoutput on,polarity,pulse width,# before output> polarity: pulse width: 0 = Negative Default is 5 (50 ms). 1 = Positive 0 to 255
3–Serial Config.
output on (mode): 0 = Mismatch or Noread 1 = Match (or Good Read) 2 = Mismatch 3 = Noread
# before output: Default is 1. 1 to 255
Example: To set Relay-2 to Mismatch and change Pulse Width to 40 ms, send <Kw2,0,4> or <Kw2,,4>.
Bar Code Output Format: <Klstatus,when to output> status: 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read when to output: 0 = As Soon As Possible 1 = End of Read Cycle
Example: To set When to Output to End of Read Cycle, send <Kl3,1>.
MS-810 Industrial Scanner User’s Manual
3-17
Page 80
Chapter 3 Noread Message Format: <Kkstatus,output> status: noread output: 0 = Disabled Default is NOREAD. 1 = Enabled Any ASCII string up to 7 digits. Example: To enable Noread Message and send the message “FAIL,” send <Kk1,FAIL>.
Beeper Format: <Kubeeper status,beeper volume>
3–Serial Config.
beeper status: 0 = On Good 1 = On Noread beeper volume: 0 = Off 1 = Level 1 2 = Level 2
3 = Level 3 4 = Level 4 5 = Level 5
Example: To set the beeper for On Noread and set the beeper volume to Off, send <Ku1,0>.
Laser On/Off Format: <KCstatus> status: 0 = Disabled1 = Enabled Example: To enable Laser On/Off, send <KC1>.
Partial Output Format: <KYstatus,start position,length> partial output status: 0 = Disabled 1 = Enabled start position: Default is 1 1 to 63 length: Default is 63 1 to 63
Example: To enable Partial Output, set start position to 5, and set length to 6 characters, send <KY1,5,6>.
3-18
MS-810 Industrial Scanner User’s Manual