MS-810 Industrial Scanner User's Manual, pages 61 to 70

Pages 61 to 70 of 144

The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-810

Page 61

Setup Menu

Setup Menu The Setup menu allows you to set specific bar code scanning parameters that affect decode rate, and if equipped with the MS-sensor, allows you to determine why the scanner did not decode a specific label within the triggered read cycle.

2–Menu Config.

Figure 2-10 Setup Menu Structure

Default Clicking the DEFAULT button will reset all parameters on the current menu to defaults. This does not take effect until it is saved to the scanner with the SEND/NO SAVE or SEND/SAVE buttons. Note: Unlike most configuration settings Scanner Type, Scans per Second, and Gain Adjustment are not saved for power-on (but are initialized) when you press Y. To save new settings to NOVRAM for these parameters, enter the <Zp> command. See “Save Scanner Type, SPS, and Gain for Power-on” on “Save Scanner Type, SPS, and Gain for Power-on,” on page 4-12.

MS-810 Industrial Scanner User’s Manual

2-39

Page 62

Chapter 2

Factory Settings Scans per Second Default:

40 (400 scans per second) for the Low Density and High Density and 50 (500 scans per second) for Standard Density.

Options:

30 to 80. Multiply the number to be entered by 10 for actual scans per second.

2–Menu Config.

Allows you to set the number of scans per second by controlling mirror motor speed. The range is 300 to 800 scans per second.

Gain Adjustment Default:

45 (nominal, unit specific, optimized at the factory before shipment)

Options:

10 to 255

Allows you to specify a gain value for the analog circuitry. Changes to Gain should typically be done by qualified technicians. Important: Before saving any changes to Gain Adjustment (see “Save Scanner Type, SPS, and Gain for Power-on” on “Save Scanner Type, SPS, and Gain for Power-on,” on page 4-12), first record the optimized factory setting for future reference.

Scanner Type Default:

Standard if the unit is configured for low density; High Density if the unit is configured for high density.

Options:

Standard, High Density

The Scanner Type “default” from the factory indicates the density type of the scanner (with the unit’s optics adjusted accordingly). Do not change this setting unless instructed to do so by a Microscan representative. Important: Entering the <Zp> command (see “Save Scanner Type, SPS, and Gain for Power-on” on page 4-12) will save the current setting for Scanner Type to NOVRAM. If you need to verify the density type of a unit, see your FIS number and contact your Microscan representative.

AGC Sampling Default:

Continuous

Options:

Continuous, Disabled, Leading Edge

Allows you to specify how automatic gain control sampling will be done. Continuous mode continually samples 14 transitions and stores the highest value of the samples and adjusts the AGC value at the end of the scan. Leading Edge mode finds the leading edge by looking for a 40 µs quiet zone followed by 14 transitions and stores the highest value of the samples and adjusts the AGC at the end of the scan. Leading Edge is especially effective when labels are skewed. Changes to AGC Sampling should typically be done by qualified technicians.

2-40

MS-810 Industrial Scanner User’s Manual

Page 63

Chapter

3

Serial Configuration

3–Serial Config.

Chapter Contents About Serial Configuration .............................................................. 3-3 Communications Port Commands ................................................... 3-5 Protocol Commands ........................................................................ 3-6 Operations Commands ................................................................. 3-10 Code Types Commands ................................................................ 3-13 Scanner Output Commands .......................................................... 3-16 Scanner Setup Commands ........................................................... 3-19

Most of the configuration changes to the scanner that can be made in the menu can also be accomplished by command strings from the host. Serial command strings are entered from an ASCII terminal. As with menu configuration commands, serial configuration commands relate to the initial scanner setup. To quickly reference the serial configuration commands, see table 3-1 on page 3-2.

MS-810 Industrial Scanner User’s Manual

3-1

Page 64

Chapter 3 Table 3-1 Summary of Serial Configuration Commands Function Comm. Port

Protocol

Operations

K Ka Ky KT Kf Kd Ke Kc KA KB Kg Kh Ki Kj Km Kn

3–Serial Config.

Kz KL KV Ko Kp Kq Kr

Code Types

Ks

Scanner Output

Kt Kx Ko P KW Kv Kw Kl Kk Ku KC KS

Scanner Setup All

3-2

KY KX KP KE KD KU K?

Command

Format

Host Port

<Kabaud,parity,stop bits,data bits> <Kymode,baud,parity,stop bits,data bits,daisy chain status,daisy Aux Port chain id> Communications Status Request <KT?> Communications Protocol <Kfprotocol,address> Preamble <Kdstatus,ASCII characters> Postamble <Kestatus,ASCII characters> LRC <Kcstatus> Response Timeout <KAtimeout setting> Intercharacter Delay <KBnumber> Triggering Mode <Kgmode,filter time> End of Read Cycle <Khmode,time> Serial Trigger Character <Kicharacter> External Trigger Level <Kjmode> Good Decode Reads <Kmnumber> <Kntype,sequential matching,match start position,match length,wild Match Code Type card character,sequence on noread,sequence on every mismatch> New Master Pin <Kzstatus> Number of Labels <KLnumber of labels,multilabel separator> Operations Status Request <KV?> Narrow Margins/Symbology ID <Konarrow margins status,symbology ID status> <Kpstatus,check digit status,check digit output status,large intercharCode 39 acter gap,fixed code length status,code length> <Kqstatus,start & stop match status,start & stop output status,large Codabar intercharacter gap,fixed code length status,code length,check digit type,check digit output> Interleaved 2 of 5 <Krstatus,check digit,check digitoutput,length 1,length 2> <Ksstatus,EAN status,supplementals UPC/EAN status,separator status,separator char.> Code 128 <Ktstatus,fixed length,length> Background Color <Kxbackground color> Narrow Margins/Symbology ID <Konarrow margins status,symbology ID status> Autodiscriminate All Codes <P> Code Types Status Request <KW?> Relay-1 <Kvoutput on,polarity,pulse width,# before output> Relay-2 <Kwoutput on,polarity,pulse width,# before output> Bar Code Output <Klstatus,when to output> Noread Message <Kkstatus,output> Beeper <Kustatus,volume> Laser On/Off <KCstatus> <KSserial command echo status,serial command beep status,control/hex Serial Verification output> Partial Output <KYstatus,start position,length> Scanner Output Status Request <KX?> Scanner Type <KPdensity> Scans per Second <KEspeed> Auto Gain Control <KDgain adjustment,AGC sampling> Scanner Setup Status Request <KU?> Return All K Commands <K?>

MS-810 Industrial Scanner User’s Manual

Page 65

About Serial Configuration

About Serial Configuration Serial Configuration Command Format The format for a serial configuration command is, <Kparameterdata,data,...etc.><initializing command>

Where: • Less than < and greater than > symbols are included as part of the commands. • “parameter,” as used here, are those character(s) that precede the data. • The “initializing command” <A> or <Z> is sent after configuration is complete. <Z> resets and saves for power up. <A> initializes the change to RAM.1 (For more information, see “Reset,” on page 4-11.) For example, the following command enables UPC and saves the change for power-on: <Ks1><Z>.

• Parameters and data are “case sensitive.” That is, characters must be entered as upper or lower case, as specified. • All data fields (except the last) must be followed by a comma (without a space). • If there is no change in a given field, then commas can be entered alone, or with the existing data (for example, <Ka,,,0> or <Ka4,1,0,0>). • All fields preceding the modified field must be included. For example, in Host Port, to change Data Bits to Eight without changing any other field, send either: <Ka,,,1> or <Ka4,1,0,1>. • All fields following the modified field can be left out. For example, in the RS-232 port, to change Baud Rate to 4800, send <Ka3>. (See examples on following pages.)

1. See “Initializing serial configuration commands” on page 3-4 for definitions and examples. MS-810 Industrial Scanner User’s Manual

3-3

3–Serial Config.

When using serial configuration commands, note also the following conventions:

Page 66

Chapter 3 Initializing serial configuration commands To ensure that a serial configuration command will take effect, you need to follow it with one of the operational commands below: <A> To reset but not save changes for power-on. <Z> To reset and save changes for power-on. For example, to change Baud Rate and reset without saving changes for power-up, send <Ka3><A>. To change Baud Rate and reset, saving the changes to NOVRAM, send <Ka3><Z>. To ensure that a command was received and accepted, you can send the Show Scanner Status command, <?>.

Concatenating Serial Commands

3–Serial Config.

Commands can be concatenated (added together) to a maximum of 64 characters in a single string or data block. Additional data blocks of 64 or less characters can be sent provided there is at least a 10 ms pause between blocks. For example, <Kc1><Kh1><Ko1><A> enables LRC, sets End of Read Cycle mode to New Trigger, enables Narrow Margins and resets the data buffers (without saving the changes for power-on).

Serial Command Status Request The status of serial commands can be requested by entering the command followed by a question mark. For example, send <Ke?> to request the status of Postamble. Commands KT?, KV?, KW?, KX?, and KU? are used to request the status of groups of serial commands (see table 3-1 on page 3-2).

Loss of Communications Making changes to communications parameters such as Baud Rate, Parity, Stop Bits, LRC, etc. without corresponding changes in linked device(s) can result in the loss of menu access. If this should occur, default the scanner with the <Zd> Restore/Save Default Configuration for Power-on command as described on page 4-12. CAUTION: Defaulting the scanner will reset all standard configuration parameters except Scanner Type, Scans per Second, and Gain Adjustment to their original default values. Note: Power must be available to the scanner during the default procedure.

3-4

MS-810 Industrial Scanner User’s Manual

Page 67

Communications Port Commands

Communications Port Commands Host Port Note: Changes made in the scanner’s communications parameters such as baud rate, parity, stop bits, LRC, etc., must be matched in the other device(s) or communications will be lost. If this occurs, default the scanner with the <Zd> Restore/Save Default Configuration for Power-on command as described on page 4-12. Format: <Kabaud rate,parity,stop bits,data bits> parity: 0 = None 1 = Even 2 = Odd stop bits: 0 = One 1 = Two data bits: 0 = Seven 1 = Eight

3–Serial Config.

baud rate: 0 = 600 3 = 4800 6 = 38.4K 1 = 1200 4 = 9600 7 = 76.8K 2 = 2400 5 = 19.2K 8 = 300

Example: To change Host Port Baud Rate to 2400, send <Ka2>.

Auxiliary Port Format: <Kymode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain id>1 mode: 0 = Disabled 1 = Transparent 2 = Half duplex parity: 0 = None 1 = Even 2 = Odd

3 = Full duplex 4 = Daisy chain stop bits: 0 = One 1 = Two baud rate: 0 = 600 1 = 1200 2 = 2400

3 = 4800 4 = 9600 5 = 19.2K

6 = 38.4K 7 = 76.8K 8 = 300 daisy chain ID data bits: 0 = Seven status 0 = Disabled 1 = Eight 1 = Enabled daisy chain I.D. any 2 ASCII characters. Default is 1/

Example: To change Aux Port Baud Rate to 2400, send <Ky2>.

Communications Status Request Format: <KT?> Returns status of each command in the group.

1. For use with Microscan’s IB-105. MS-810 Industrial Scanner User’s Manual

3-5

Page 68

Chapter 3

Protocol Commands If selecting one of the options from 0 to 4 (Point-to-Point, Point-to-Point with RTS/CTS, Point-to-Point with XON/XOFF, Point-to-Point with RTS/CTS and XON/XOFF, or Polling Mode D), use this format: Format: <Kfprotocol>1 protocol: 0 = Point-to-Point 1 = Point-to-Point with RTS/CTS 2 = Point-to-Point with XON/XOFF 3 = Point-to-Point with RTS/CTS and XON/XOFF

4 = Polling Mode D 5 = Multidrop (requires address) 6 = User Defined 7 = User Defined Multidrop

3–Serial Config.

Example: To change the Protocol to Polling Mode D, send <Kf4>. If selecting Multidrop (5), you must define an address and append it to the command string. Format: <Kf5,address> protocol: 5 = Multidrop address: Any number from 1 to 50

Example: To change the Protocol to Multidrop with an address of 33, send <Kf5,33>. If selecting User Defined (6) or User Defined Multidrop (7), complete the format by either choosing new parameters or concatenating unchanged data fields (separate by commas). TIP: For User Defined, first select Point-to-Point <Kf0> and then User Defined <Kf6...>. For user Defined Multidrop, first select Multidrop <Kf5>, then User Defined Multidrop <Kf7...>. Format: <Kfprotocol,RES,address,REQ,EOT,STX,ETX,ACK,NAK,from host> protocol: 6 = User Defined; From Host: 0 = disabled 1 = enabled

1. Polling Mode D, Multidrop, User Defined, and User Defined Multidrop are for use with Microscan’s IB-105.

3-6

MS-810 Industrial Scanner User’s Manual

Page 69

Protocol Commands Example: To select an unpolled ACK/NAK User Defined protocol with LRC disabled, send <Kf0><Kf6,,,,,,,^F,^U><Kc0>.1 ACK and NAK will be displayed in the menu.

Note: Address, can be assigned any ASCII character except a null. Control characters are used to define RES through NAK (except Address). Table 3-2 lists the control characters used for these data fields. (Refer to Table A-4, “ASCII Table with Control Characters,” on page A-10 for more information.)

Format: <Kf protocol, RES, address, REQ, EOT, STX, ETX, ACK, NAK> protocol: 7 = User Defined Multidrop Example: To customize multidrop protocol’s STX (start of text) and EOT (reset) sequence and assign an address of 2, send <Kf5,2><Kf7,^M,,,^A>. The <Kf5,2> portion of the command enables the standard Multidrop protocol and assigns a Multidrop address. ^M is the new STX and ^A the new EOT. All other protocol characters will retain their standard Multidrop values.2 1. <Kf0> nulls the address and <Kc0> disables LRC. A control character, although conventionally represented here and in the ASCII table on page A-10 as two characters (^F or ^U, etc.), is actually a single ASCII character that is entered on the keyboard by holding down the control key while pressing the desired letter. 2. A control character, although conventionally represented here and in the ASCII table on page A-10 as two characters (^F or ^U, etc.), is actually a single ASCII character that is entered on the keyboard by holding down the control key while pressing the desired letter. MS-810 Industrial Scanner User’s Manual

3-7

3–Serial Config.

Explanation of the From Host option Suppose STX, ETX and EOT are defined in the MS-810, the trigger counter is currently T/ 00000, and you want to send the Trigger Counter Request command to the scanner. Defined Protocol: STX, ETX, EOT Trigger Counter Status: T/00000 Host Command Request: <T> (Trigger Counter Request Command) The command string format from the host would depend on the From Host setting. If From Host is disabled, <T> (Trigger Counter From Host Disabled Request command) would be the required format from the host to cause the scanner to return STX T/ <T> MS-810 HOST 00000 ETX EOT. However, if From Host is enabled, STX T/00000 the required host command string would be STX ETX EOT <T> ETX EOT to receive the same response from the scanner. In either case the data string From Host Enabled returned by the scanner always includes the defined STX <T> ETX EOT HOST MS-810 protocol. In this example, that returned data would STX T/00000 be STX T/00000 ETX EOT. ETX EOT

Page 70

Chapter 3 Note: Address, can be assigned any ASCII character except a null. Control characters are used to define RES through NAK (except Address). Table 3-2 lists the control characters used for these data fields. (Refer to Table A-4, “ASCII Table with Control Characters,” on page A-10 for more information.)

3–Serial Config.

Table 3-2 Protocol Commands Protocol Command (Mnemonic displayed on Microscan menu)

Control Characters (Entered in menu or serial command)

Effect of Command

RES

^D

Reset

REQ

^E

Request

EOT

^D

Reset

STX

^B

Start of Text

ETX

^C

End of Text

ACK

^F

Acknowledge

NAK

^U

Negative Acknowledge

Preamble Format: <Kdstatus,preamble character(s)> status: preamble character(s): 0 = Disabled Enter one or two preamble characters except a null (00H). Default is ^M. 1 = Enabled Example: To enable Preamble with just one character, an FF (form feed), send <Kd1,^L>.

Postamble Format: <Kestatus,postamble character(s)> status: 0 = Disabled 1 = Enabled postamble character(s): Enter one or two postamble characters except a null (00H). Default characters are ^M^J.

Example: To disable Postamble, send <Ke0>.

LRC

3-8

MS-810 Industrial Scanner User’s Manual