For the Microscan MS-810

Page 51

Code Type Menu

UPC Default:

Disabled

Options:

Disabled, Enabled

When enabled, the scanner will read UPC version A and UPC version E only.

EAN Disabled

Options:

Disabled, Enabled

Note: UPC must be enabled for EAN to take effect. When EAN is enabled, the scanner will read UPC version A, UPC version E, EAN 13, and EAN 8. It will also append a leading zero to UPC version A label information and transmit 13 digits. If you do not want to transmit 13 digits when reading UPC version A labels, disable EAN.

Supplementals Default:

Disabled

Options:

Disabled, Enabled, Required

Allows the scanner to read supplemental bar code data that has been appended to the standard UPC or EAN codes.

Enabled When Supplementals is set to Enabled, the UPC main and supplemental label are considered to be separate labels. Therefore Number of Labels must be set to 2 and a multilabel separator will be inserted between the label data and the supplemental label data. For example, if Supplementals is enabled, Number of Labels is set to 2, and the Multilabel Separator Character is defined as a #, the data will be displayed as: LABEL # SUPPLEMENTAL If you are using two labels with Supplementals, set Number of Labels to 4. Note: Under no circumstances will a supplemental label be output without a main label. Note: Do not set Triggering Mode (page 2-16) to Continuous Read 1 Output. Enabling Continuous Read 1 Output will cause Number of Labels to default to 1.

Required When set to Required, the UPC main and supplemental labels are considered to be one label. If either the main or supplemental label is not read, a single noread message will be output. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the Separator Character, then the data will be displayed as: LABEL * SUPPLEMENTAL. If set to disabled, the following will be displayed: LABEL SUPPLEMENTAL. MS-810 Industrial Scanner User’s Manual

2-29

2–Menu Config.

Default:

Page 52

Chapter 2 Note: If additional labels - other than the main or supplemental - will be read in the same read cycle, Number of Labels should be set accordingly.

Separator Default:

Disabled

Options:

Disabled, Enabled

2–Menu Config.

Allows you to insert a character between the standard UPC or EAN code and the supplemental code when Supplementals is set to Required.

Separator (character) Default:

, (comma)

Options:

Any ASCII character.

Allows you to change the separator character from a comma to a new value. Note: UPC separator character, if used, must be different than the multilabel separator.

Code 128 Default:

Disabled

Options:

Disabled, Enabled

Fixed Code Length Default:

Disabled

Options:

Disabled, Enabled

Allows you to increase data integrity by ensuring that only one label length will be accepted.

Code Length Default:

10

Options:

1 to 64

Note: Fixed Code Length must be enabled for Code Length to take effect. Allows you to specify the exact number of characters that the scanner will recognize. The scanner will ignore any code not having the specified length.

Narrow Margins Default:

Disabled

Options:

Disabled, Enabled

Allows the scanner to read bar codes with quiet zones less than 10 times the width of the narrow bar element. “Quiet zone” is the space at the leading and trailing ends of a label. Each quiet zone can be as narrow as only five times the width of the narrow bar element when Narrow Margins is enabled.

2-30

MS-810 Industrial Scanner User’s Manual

Page 53

Code Type Menu

Symbology ID Default:

Disabled

Options:

Disabled, Enabled

When enabled, the scanner reads and outputs a three character prefix: 1. ] (close bracket character) indicating the presence of a symbology ID 2. A, F, I, E, or C A = Code 39; F = Codabar; I = I 2 of 5; E = UPC/EAN; C = Code 128 If check digit is not enabled, the output is 0 (Col. 1). If check digit and check digit output are enabled, the output is as shown in column 2. If check digit is enabled, but output is disabled (Col. 3), the output is as shown in Col. 4, which is the sum of Col. 2 and Col. 3. Table 2-1 Symbology Identifier Option Values

Column 1

Column 2

Column 3

Column 4

No check character

Check digit and output enabled

Check digit output disabled

Sum of Column 2 and 3

Code 39

0

1

(2)

3

Codabar

0

2

(4)

6

I 2 of 5

0

1

(2)

3

UPC/EAN Always zero, do not follow AIM spec. Code 128

Example 1: For Code 39, if check digit and check digit output are both enabled, a 1 will be output; but if check digit output is disabled, a 3 (the sum of column 2 and column 3) will be output. Example 2: For Codabar, if check digit and check digit output are both enabled, a 2 will be output; but if check digit output is disabled, a 6 (the sum of 2 and 4) will be output.

Autodiscrimination Default:

Disabled

Options:

Disabled, Enabled

When enabled, all symbology types are enabled. MS-810 Industrial Scanner User’s Manual

2-31

2–Menu Config.

3. A single number indicating the status of the check digit character (table 2-1):

Page 54

Chapter 2

Background Color Default:

White

Options:

White, Black

2–Menu Config.

Allows the scanner to be set to read symbols on white (light) or black (dark) backgrounds.

2-32

MS-810 Industrial Scanner User’s Manual

Page 55

Output Menu

Output Menu

2–Menu Config.

Figure 2-9 Scanner Output Menu Structure

Default Clicking the DEFAULT button will reset all parameters on the current menu to defaults. This does not take effect until it is saved to the scanner with the SEND/NO SAVE or SEND/SAVE buttons. Note: Bar code output data and noread messages are transmitted on pin 2 under conditions set principally in Bar Code Output.

Relay-1 and Relay-2 Relay pulses are transmitted via pins 7 and 14 (Relay-1 and Relay-2, respectively) and individually configured under conditions set in Relay-1 and Relay-2. Note: Relay-1 output also causes closure of a relay in the IB-105 box, accessible through pin 15 of the IB-105 host connector only in the 5 V version (see table A-9 on page A-23). Relay-1 and relay-2 can allow simultaneous output under individually programmed conditions.

MS-810 Industrial Scanner User’s Manual

2-33

Page 56

Chapter 2 Output On Default:

Mismatch or Noread

Options:

Mismatch or Noread, Match, Mismatch, Noread

Note: If Output On is set to Mismatch or Noread, Match, or Mismatch, a relay pulse will not output unless Match Code Type (page 2-22) is not disabled and a master label is downloaded into memory (page 2-21).

2–Menu Config.

Note: To send a pulse on a Good Read, enable Match and disable Match Code Type (see “Match Code Type” on page 2-22). Allows you to set the conditions that will output a relay pulse either to pin 7 (Relay-1) or to pin 14 (Relay-2).

Mismatch or Noread Sends a pulse when the label's data does not match that of the master label or the label is not decoded before the end of the read cycle.

Match (or Good Read) Sends a pulse when the decoded label matches the master label. (To send the pulse on a good read, disable Match Code Type on page 2-22.)

Mismatch Sends a pulse when the label’s data does not match that of the master label.

Noread Sends a pulse when the label’s data is not decoded before the end of the read cycle.

Polarity Default:

Negative

Options:

Negative, Positive

Allows you to choose between positive and negative output signals for the relay output pin that is enabled.

Pulse Width (in 10 ms incs) Default:

5 (.05 seconds). Corresponds to 50 ms displayed in the menu.

Options:

0 to 255 (0 to 2.55 seconds). Divide the number to be entered by 100 for time in seconds.

Allows you to set the duration of the good match/noread output signals at the relay output pin that is enabled. Note: After completing changes to Output On, Polarity, and Pulse Width, press M to advance to Bar Code Output and continue scrolling through the Scanner Output options.

2-34

MS-810 Industrial Scanner User’s Manual

Page 57

Output Menu # Before Output Default:

1

Options:

1 to 255

Allows you to determine the number of consecutive hits (matches, mismatches, or noreads as configured by Output On) that must occur before a relay pulse will be sent from Relay-1 or Relay-2. For example, if # Before Output is set to 3 and Relay-1 is set to Noread, then relay-1 will not fire until 3 consecutive noreads have occurred.

Bar Code Output Default:

Good Read

Options:

Good Read, Disabled, Match, Mismatch

Note: If Bar Code Output is set to Match or Mismatch, label data will not output unless Match Code Type (page 2-22) is enabled and a master label is downloaded into memory (page 2-21). Allows you to choose the conditions under which label data (or noread messages) will be sent to the host.

Good Read The scanner outputs on any good read independent of how Match Code Type is set.

Disabled The scanner does not output both label data and noread messages to the serial port.

Match (with Match Code Type enabled) The scanner outputs when the label data information matches the master label. However, if Match Code Type is disabled it outputs on any good read.

Mismatch (with Match Code Type enabled) The scanner outputs when the label data information does not match the master label. However, if Match Code Type is disabled it outputs on any good read.

When to Output (bar code data) Default:

As Soon As Possible

Options:

As Soon As Possible, End of Read Cycle

Allows you to choose when bar code data is sent to the host.

As Soon As Possible Causes bar code data (good reads) to be transmitted immediately upon a good decode. MS-810 Industrial Scanner User’s Manual

2-35

2–Menu Config.

Note: The hits must be consecutive and each one must match the configured Output On condition. Any interruption in the consecutive sequence will result in a reset and cause the scanner to start the count over.

Page 58

Chapter 2 End of Read Cycle Causes bar code data output to be delayed until the end of the read cycle.

2–Menu Config.

Noread Message Default:

NOREAD

Options:

Up to seven ASCII characters (except NUL)

Allows you to define any combination of ASCII characters (except NUL) up to seven characters as the noread message. When enabled, and if no bar code label has been decoded before timeout or the end of the read cycle, the noread message will be transmitted to the host.

Noread Output (enable/disable) Default:

Enabled

Options:

Enabled, Disabled

Note: If Noread Output is enabled, the noread message will only output if Bar Code Output (page 2-35) is also enabled. Allows you to enable or disable the noread message.

Beeper Status Default:

On Good

Options:

On Good, On Noread

A beep is emitted either after each good read of a bar code label or after each noread. Note: The beep period is short for triggered modes when a new trigger occurs immediately or the output is delayed to the end of the read cycle on edge and serial triggers.

Beeper Volume Default:

Level 4

Options:

Level 4, Level 5, Off, Level 1, Level 2, Level 3

Laser On/Off Default:

Disabled

Options:

Disabled, Enabled

Note: A serial or external trigger (see “Triggering Mode” on page 2-16) must be enabled for Laser On/Off to take effect. When enabled, the laser is ON only during the read cycle. When disabled, the laser operates continuously. Note: Laser On/Off does not relate to the Enable Laser Scanning (<H>) or Disable Laser Scanning (<I>) operational commands on page 4-6.

2-36

MS-810 Industrial Scanner User’s Manual

Page 59

Output Menu K Command Options

Echo K Command Default:

Disabled

Options:

Disabled, Enabled

Note: It is important to note that if a command with multiple fields is processed, some of the fields may have been processed properly following an “invalid” command. These changes will be in the string echoed back so that the user will know what did or did not change.

Beep on K Default:

Disabled

Options:

Disabled, Enabled

When enabled, the scanner beeps once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the scanner beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response.

Control Character Output Default:

Ctrl

Options:

Ctrl, Hex

Determines response to an Echo K or status request command. When set to CTRL, ASCII control character output includes a control character as shown in the “Ctrl” column of Table A-4, “ASCII Table with Control Characters,” on page A-10. When set to Hex, the output is the actual character.

MS-810 Industrial Scanner User’s Manual

2-37

2–Menu Config.

When enabled, serial configuration commands (“K” commands) will be processed and the new string for that command will be echoed back to the host. If an invalid command is sent to the host, the scanner will echo back the current setting of that command. For example, if the current Noread Message is “NOREAD” and <Kk1,NONSENSE> is entered, the scanner will echo back: <Kk1,NOREAD>. In this example the attempted entry “NONSENSE” exceeds the maximum allowable seven characters. Therefore it is rejected and the current NOREAD message is echoed back and remains the Noread Message.

Page 60

Chapter 2 Partial Output Default:

Disabled

Options:

Disabled, Enabled

2–Menu Config.

When enabled, allows you to pre-select portions of labels to be transmitted by the scanner. In multilabel mode, partial output is performed on each separate label. For example, if Start Position is set to 3 and Partial Length is set to 5, the following labels are transmitted as follows: 1234567890 as “34567” 1234 as

“34”

1234,abcde as “34,cde” (two labels with separator) 12 as

““

Start Position Default:

1

Options:

1 to 63

Allows you to determine the first character from the beginning of a label to transmit.

Partial Length Default:

63

Options:

1 to 63

Allows you to determine the number of characters to be transmitted.

2-38

MS-810 Industrial Scanner User’s Manual