Page 21

Attach Cabling 1–Setup and Inst.

Trigger Connector1 The scanner’s trigger connector (figure 1-7) is a 9-pin, circular, twist-lock type that mates with a Microscan socket connector (P/N 98-200002-01) (not supplied with the scanner). Trigger pin assignments are listed in table 1-4. A programmable pulse to internal relay contacts will make or break connection between pins 7 and 9 for external use (up to 200 mA or 4 VA).

1

2 4

3

5

6 8

7 9

Figure 1-7 Trigger Connection

Table 1-4 Trigger Connector Pin Assignments

Pin

Function

1 2 3 4 5 6 7 8 9

Power ground Supply +12 VDC (out) @ 50 mA Optional power input to the scanner (10 to 28 VDC unreg.) Trigger Input from the object detector (3 to 24 VDC) Power ground Optional power input to the scanner (10 to 28 VDC unreg.) Relay contact 1, (200 mA or 4 VA) Relay--output #1 (source or sink 4 mA) (see table 1-3) Relay contact 2 (200 mA or 4 VA)

Figure 1-8 shows examples of positive and negative external trigger inputs that could be applied to the trigger port. (Shown in the untriggered state.) Scanner Trigger Connector P ositiv e Trigger

N egativ e Trigger 1

Pwr Gnd

2

+1 2 VDC

3

10 to 28 V DC (in)

Trigger input

4

Trigger input

5

Pwr Gnd

5

Pwr Gnd

6

10 to 28 V DC (in)

6

10 to 28 V DC (in)

7

Relay Contact 1

7

Relay Contact 1

8

Noread Output

8

Noread Output

9

Relay Contact 2

9

Relay Contact 2

1

Pwr Gnd

2

+1 2 VD C

3

10 to 28 V DC (in)

4

+12 VDC (o ut)

+12 VDC (o ut)

NO

(Normally Open Switch)

Triggering Device

Scanner Trigger Connector

NC

(Normally Closed S witch)

Triggering Device

Figure 1-8 Trigger Input Diagrams (untriggered) 1. Microscan offers an object detector for this connector (P/N 99-440001-03). Other trigger sources can also be used. Mechanical switches, relays, etc. - which tend to be slow and bouncy and produce multiple trigger signals - are not recommended unless equipped with optical sensors or filtered transitions (optical, Hall effect, or DC solid state relays). MS-7100/7180 Industrial Scanner User’s Manual

1-11

Page 22

1–Setup and Inst.

Chapter 1

Setup and Installation

Power Connector The power connector (figure 1-9) is a 9-pin, circular, twist-lock connector (Amp CPC series) that mates with a supplied 9-pin socket connector (P/N 98-200002-01). The pin assignments are listed in table 1-5. Note: Trigger and host connectors can also supply power.

Pins 1, 3, 6, 7, 8, and 9 are identical to those of the trigger connector. Pins 2 and 4 provide access to the scanner for the auxiliary RS-232 port and are similar to pins 18 and 19 of the host 28-pin connector. Pin 5 is internally connected to pin 1 of the host connector and to the external case to provide a path for electrostatic discharge or AC faults to pass directly to ground. It is intended to be connected to a “safety ground” (also known as “green-wire” or “third wire” ground). It is particularly useful in installations where the case is not grounded through its mounting plate or when this connection must be guaranteed even when the unit is unmounted. This connection allows hazardous currents, such as electrostatic discharge or AC faults, to pass safely to ground instead of traveling through the unit’s circuits or signal cabling.1 Table 1-5 Power Connector Pin Assignments

Pin 1 2 4

5

3

1

Power ground

2

Aux. transmit (RS-232)

3

Power input 10 to 28 VDC unreg. @ 9W max. with less than 1 V p-p ripple

4

Aux. receive data (RS-232)

5

Chassis ground

6

Power input 10 to 28 VDC unreg. @ 9W max. with less than 1 V p-p ripple

7

Relay contact 1, (200 mA or 4 VA)

8

Relay--output #1 (source or sink 4 mA)

9

Relay contact 2 (200 mA or 4 VA)

6 8

7 9

Figure 1-9 Power Connector

Function

1. Note that the path established by pin 1 of the host connector, which goes through the host cable shield, is not effective for this purpose.

1-12

MS-7100/7180 Industrial Scanner User’s Manual

Page 23

Configure Scanner

Settings for Communications, Operations, Code Types, and User Outputs are stored in nonvolatile memory and can be configured from a host or auxiliary terminal by menu (Chapter 2, “Menu Configuration”) or by serial command (Chapter 3, “Serial Configuration”). For explanations of configuration settings, see Chapter 2, “Menu Configuration.” To establish communication you will need to match the host’s or auxiliary terminal’s communication settings with your scanner’s settings (see “Communications Menu” on page 2-5). Also make certain that the code type enabled in the scanner matches that of the label being used (see “Code Types Menu” on page 2-22). Hint: Enabling Autodiscrimination in the menus (or with the <P> command) will allow your scanner to read all of the listed code types. Communicating with an ASCII Terminal The scanner communicates in full duplex, terminal mode with no handshake. It also recognizes carriage returns and line feeds. The host or ASCII terminal with must match the following default settings before any communication can take place: 9600 Baud Rate, Seven Data Bits, Even Parity, and One Stop Bit. A PC or Macintosh computer can be used as an ASCII terminal if connected as shown under “Host Connector” and running a communications program set to the above defaults. See your computer manual for communication’s port pinouts.

MS-7100/7180 Industrial Scanner User’s Manual

1-13

1–Setup and Inst.

7 Configure Scanner

Page 24

1–Setup and Inst.

Chapter 1

Setup and Installation

8 Position Scanner and Label

Before testing and calibrating, you will need to position the scanner and label in a manner that matches as nearly as possible the actual conditions of your application. a. Position the scanner and label, taking care to avoid excessive tilt, skew, or pitch.1 b. Pitch label slightly as shown in figures 1-10 and 1-11 to avoid specular reflection, the return of direct, non-diffused light.2 Another way to avoid specular reflection is to skew the scanner slightly in relation to the label.

Bar code label

Ske w axis

Skew axis Bar code label

Tilt axis

Scan line

Tilt axis

M S -7 180 S canner M S -7100 Scanner

Pitch axis

Pitch axis Scan line

Figure 1-10 MS-7100 Orientation

Figure 1-11 MS-7180 Orientation

For more information, See Appendix C, “Orientation” on page A-6.

1. Maximum tilt is determined by label characteristics and number of scans required. Maximum skew is ±40°; maximum pitch is ±50°. 2. The specular reflection zone is a narrow zone straight out from the scanner in which direct reflected light from a label can distort the scanner’s ability to distinguish bars from spaces. For the MS-7100 scanner, specular reflection is avoided by pitching labels at least 1.5 ° at ranges from 0 to 20 inches (50.8 cm) from the scanner, and thereafter at diminishing angles, for example, 0.75° at 40 inches (101.6 cm), and 0.5° at 60 inches (152 cm). For the MS-7180 raster scanner, specular reflection is avoided by pitching labels at least 5° from a line perpendicular to the raster mirror.

1-14

MS-7100/7180 Industrial Scanner User’s Manual

Page 25

Test and Autocalibrate

If your proposed scanning range is not within the range specified in table 1-1 on page 1-3, go to step e. If your proposed scanning range is within the range specified in table 1-1 on page 1-3, test read rate by doing the following: a. Position the label in front of a functioning scanner and launch the read rate test with a <C> command from the host terminal. (See “Status Commands” on page 5-5.) b. Observe read rate. (Read rate is the percentage of scans decoded.) c. Check depth-of-field (minimum/maximum range) by moving the label closer and further relative to the scanner and noting the points where the read rates fall below a level acceptable to your application. Ideally, the label used in your application should pass through or near the center of the depth-of-field. d. Repeat steps a through c for other labels used in your application and end the read rate test with a <J> command. If the read rate is acceptable, go to Step 11, “Install Scanner,” on page 1-18. If the read rate is not acceptable, continue with the following steps: e. Do Autocalibration (see Chapter 4, “Calibration.”) and check Read Rate within the Calibration program. (Autocalibration optimizes the read rate by automatically cycling through the gain and tracking settings and selecting the combination that achieves the highest read rate.) f. If the results are not satisfactory after doing Autocalibration, go to Step 10, “Adjust Other Scanning Parameters,” on page 1-16. Important: If, after Autocalibration or other adjustments you have changed the read range or other parameter used in the number of scans formula, you should recalculate the Number of scans (Step 5, “Calculate Number of Scans,” on page 1-6). Note: Variations between labels are common. For this reason, the greater number of sample labels you test, the more likely you are to achieve optimum read rates.

MS-7100/7180 Industrial Scanner User’s Manual

1-15

1–Setup and Inst.

9 Test and Autocalibrate

Page 26

1–Setup and Inst.

Chapter 1

Setup and Installation

10 Adjust Other Scanning Parameters

Autocalibration (in step 9) is the preferred method of increasing read rate. However, you might need to adjust other scanning parameters as well. This section lists various adjustments (other than Autocalibration) that may improve read rates. After changing any of the parameters described in this section, a. If applicable, recalculate the number of scans (Step 5, “Calculate Number of Scans,” on page 1-6). b. Repeat Step 9, “Test and Autocalibrate,” on page 1-15 (if adjusting Gain or Tracking, omit sub-steps e and f).1 c. Compare the new read rate results with those obtained before changes were made.

Scan Rate Scan Rate is a function of motor speed and adjustable from within the Calibration Setup menu. The scanner is factory set at the upper rate of 1000 scans per second (sps), although it can be user adjusted to as low as 600. A slower scan rate may allow greater label range and/or higher read rates, but at the cost of fewer scans per label. For example, if you have calculated that a label in your application will receive 98 scans with a scan rate of 1000 sps, then slowing the scan rate to 800 sps will diminish the number of scans the label will receive to 78, a number that should be well above your minimum. To adjust scan rate (motor speed), send the <t> command to the scanner and follow the screen cues. For more information, see “Motor Speed” on page 4-6.

Range Adjusting the label’s range, if possible, is one of the quickest and most effective ways to improve read rates. However, in some applications you may need to select a less than optimum range, or one that is beyond the fringes of the ranges listed in table 1-1 on page 1-3.

1. Changes in Gain and Tracking will be superceded by Autocalibration.

1-16

MS-7100/7180 Industrial Scanner User’s Manual

Page 27

Adjust Other Scanning Parameters

Increasing scan width will increase the number of scans in a picket fence oriented application. Scan width is linked with scan range (as shown in Step 3, “Estimate Scan Width,” on page 1-4) and changing one will usually require a change in the other.

Label Speed Applies to both picket fence and ladder oriented labels. If your application allows it, label speed (the time in seconds in which a label is fully within the scan width of the scanner) is an effective way to alter the number of scans.

Label Dimensions, Label Density, and Label Ratio Not usually an option in most applications, but changes to label parameters can affect number of scan calculations and possibly read rates. If your application allows it, shortening the length of a picket fence label means the label will be in the scan range longer and hence receive a greater number of scans. Increasing the height of a ladder label means it will receive more scans. Changing label density and/or ratio is another way ranges, read rates, etc. can be altered.

Gain, Tracking, Bandwidth, and Clock Speed These adjustments, typically made by technicians, are done from within the Calibration Setup menu. Of these, Gain and Tracking are already adjusted automatically by Autocalibration, and changes to Bandwidth and Clock Speed will generally have a limited effect on read rates. See Chapter 4, “Calibration.”

MS-7100/7180 Industrial Scanner User’s Manual

1-17

1–Setup and Inst.

Scan Width

Page 28

1–Setup and Inst.

Chapter 1

Setup and Installation

11 Install Scanner

The scanner can be mounted directly to a mounting surface of your choice, or indirectly, via a mounting plate. To permanently mount the scanner: a. Position the scanner in place devoid of sunlight, bright lights, or laser light from other sources. b. Before mounting, ensure that there is clearance at the rear of the scanner for the connectors and cables being used. c. Use the measurements provided in figure 1-12 to locate centers of mounting holes and drill four 0.203 inch or four 6.7 mm holes. Caution: Penetration depth of screws should not exceed 0.3 inch maximum. Caution: To prevent twisting or distortion of the scanner housing, ensure that the surface or bracket to which the scanner will be mounted is flat. If necessary, use only three mounting screws instead of four.

1.11" (2.82)

5.3" (13.59)

5.65" (14.35) 3.25" (8.26)

BO TTO M

M4 x 0.7 7.1 mm deep

Front

0.57" (1.45)

4.41" (11.2)

0.57 in. (1.45)

5.56" (14.13)

Figure 1-12 Bottom Mounting Holes of MS-7100 (not to scale)

1-18

MS-7100/7180 Industrial Scanner User’s Manual

Page 29

Install Scanner 1–Setup and Inst.

1.11" 2.82 cm

3.25" 8.26 cm 8.72" 22.15 cm

8.42" 21.39 cm M4 x 0.7 7.1 mm deep

0.57" 1.45 cm

4.41" 11.20 cm

0.57" 1.45 cm

5.56" 14.12 cm

Figure 1-13 Bottom Mounting Holes of MS-7180 (not to scale)

MS-7100/7180 Industrial Scanner User’s Manual

1-19

Page 30

1–Setup and Inst.

Chapter 1

Setup and Installation

Operational Tips Do: • Check inputs (label speed, length, height, etc.) to ensure the desired number of scans per label. • Avoid excessive tilt, pitch, and skew of the bar code label. • Check the label for readability by doing a read rate test. If there is any question about the label's readability, contact your Microscan representative. • After changing any parameter that might affect read rate, repeat read rate test, and if necessary, Autocalibration. • Clean the laser window with a clean, dry cotton swab on a regular basis. Do Not: • Aim the scanner into direct light or sunlight. • Aim the scanner into a photo detector or other light-emitting device. • Obstruct the laser window with mounting hardware or other objects. • Connect chassis of scanners and host to different ground potentials (see “Ground and Shield Considerations” on page A-9). • Operate the scanner in excessive temperature environments (see “Appendix A, Scanner Specifications” on page A-2).

1-20

MS-7100/7180 Industrial Scanner User’s Manual