The text of a manual · part 2 of 14
MS-7100/7180 Industrial Scanner User's Manual, pages 11 to 20
Pages 11 to 20 of 138
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-7100 and Microscan MS-7180
Page 11
1
1–Setup and Inst.
Chapter
Setup and Installation
Chapter Contents Step 1 - Plan Scanning System ........................................................... 1-2 Step 2 - Verify Read Range ................................................................. 1-3 Step 3 - Estimate Scan Width .............................................................. 1-4 Step 4 - Determine Raster Height and Arc (7180) ............................... 1-5 Step 5 - Calculate Number of Scans.................................................... 1-6 Step 6 - Attach Cabling ........................................................................ 1-8 Step 7 - Configure Scanner .............................................................. 1-13 Step 8 - Position Scanner and Label ................................................. 1-14 Step 9 - Test and Autocalibrate ......................................................... 1-15 Step 10 - Adjust Other Scanning Parameters.................................... 1-16 Step 11 - Install Scanner.................................................................... 1-18 Operational Tips................................................................................. 1-19
This chapter provides step-by-step instruction for setting up and installing the MS-7100 or MS-7180 scanner to obtain optimum read rates.
MS-7100/7180 Industrial Scanner User’s Manual
1-1
Page 12
1–Setup and Inst.
Chapter 1
Setup and Installation
1 Plan Scanning System
Before installing the industrial scanner you should sketch out a diagram of your scanning system, showing equipment, connector and cable types, and cable lengths.
Figure 1-1 shows a possible scanning system setup. There are three cable connectors on the scanner: the 28-pin host connector (see figure 1-5 on page 1-9) the 9-pin trigger connector (see figure 1-7 on page 1-11) and the 9-pin power connector (see figure 1-9 on page 1-12).
O ptional M onitor
Bar-coded item flow
M S-5000 M ultidrop Concentrator
O bject Detector 9-pin M S -7100/7100 Scanner
28-pin Host
9-pin Unregulated 10 to 28 V DC pow er supply
Figure 1-1 System Diagram
1-2
MS-7100/7180 Industrial Scanner User’s Manual
Page 13
Verify Read Range
Table 1-1 shows readable ranges and maximum scan widths for specific bar code density (narrow-bar-width) types. Use this table as a reference to verify that the planned range for your label falls within one of the listed ranges. Table 1-1 MS-7100/7180 Read Range and Scan Widths
NarrowBar-Width
Read Rangea MS-7100
Maximum Scan Width MS-7180
Low Density
MS-7100
MS-7180 b
.020”
6” to 23” (15.2 to 58.4 cm)
4” to 20” (10.2 to 50.8 cm)
13” (33.0 cm)
12” (30.5 cm)
.030”
4” to 34” (10.2 to 86.4 cm)
2” to 32” (5.1 to 81.2 cm)
18” (45.7 cm)
16” (40.6 cm)
.040”
10” to 44” (25.4 to 112 cm)
8” to 42” (20.3 to 106.7 cm)
25” (63.5 cm)
22.5” (57.2 cm)
.050”
10” to 55” (25.4 to 140 cm)
8” to 50” (20.3 to 127 cm)
34” (86.4 cm)
31” (78.8 cm)
7” (17.8 cm)
High Density .010”
6” to 11” (15.2 to 27.9 cm)
4” to 8.5” (10.2 to 21.6 cm)
7.5” (19.1 cm)
.015”
5” to 16” (12.7 to 40.6 cm)
3” to 13.5” (7.62 to 34.3 cm)
10.5” (26.7 cm)
9.5” (24.1 cm)
.020”
3” to 16” (7.6 to 40.6 cm)
1” to 14” (2.54 to 35.6 cm)
10.5” (26.7 cm)
9.5” (24.1 cm)
.030”
4” to 20” (10.2 to 50.8 cm)
2” to 18”(5.1 to 45.7 cm)
13.5” (34.3 cm)
13” (33 cm)
.040”
4” to 20” (10.2 to 50.8 cm)
4” to 18”(10.2 to 45.7 cm)
13.5” (34.3 cm)
13” (33 cm)
Ultra High Density .005”
2” to 4.25” (5.1 to 10.8 cm)
1” to 3.5” (2.54 to 8.9 cm)
3.25” (8.3 cm)
2.25” (5.7 cm)
.0075”
2” to 5” (5.1 to 12.7 cm)
1” to 3.5” (2.54 to 8.9 cm)
3.75” (9.5 cm)
2.5” (6.4 cm)
a. Read range is the distance of the label from the scanner (measured from the front of the scanner bezel) in which the label can be reliably read. The distance between the minimum and maximum ranges is the depth of field. b. FIS (Final Instruction Sheet) option.
Note: Optimum read rates can be expected at the center of the depth of field (halfway between minimum and maximum read range) for a given bar code density.
For information on label orientation, see Appendix C, “Orientation,” on page A6.
MS-7100/7180 Industrial Scanner User’s Manual
1-3
1–Setup and Inst.
2 Verify Read Range
Page 14
1–Setup and Inst.
Chapter 1
Setup and Installation
3 Estimate Scan Width
Scan width is that portion of the scan line in which a label can be read. For ladder oriented labels, scan width must only be wide enough to fully cover the label length, including quiet zones. With picket fence oriented labels, scan width is a factor in determining the time during which the label can be read. (See Appendix C, “Orientation,” on page A-6) The greater the scan width, the longer a picket fence label will be in the scan range, and the more scans it will receive.
Use figure 1-2 to estimate the scan width that corresponds to the applicable read range. For example, a picket fence label moving across the scan line at 43 inches (109 cm) from the scanner will have a scan width of approximately 33 inches (83.8 cm). Scan W idth 60 cm
150
60
140
55 in. 25
50 20
30
40 15
20
10
10 5
0 0
10
20 5
30 10
40 15
50
60
20
25
130
150
60
140
55
130 50
50
120
120 45
110 100
40
90
35
M S -7 18 0 R a n ge s
45
M S -7 10 0 R a n ge s
110
Low Density
80 30 70 25
Low Density Scanner
40
35
80 30 70 25
20
50 40
15
10 20
High Density Scanner
Ultra High Density Scanner
Ultra High Density Scanner
High Density Scanner
5
20
15
30 10 20 10
0 0 in. cm R ange
5
0 0 in. cm R ange
Figure 1-2 MS-7100/7180 Ranges and Scan Widths
1-4
90
60
30
10
40
Scanner
60 50
100
MS-7100/7180 Industrial Scanner User’s Manual
Page 15
Determine Raster Height and Arc
(MS-7180 only)
In setting up the MS-7180 raster scanner, raster height depends on the raster arc and label distance (range) from the scanner. In figure 1-3 raster height and raster arc are shown at their maximum with raster arc set to 45°. Both the top offset and bottom offsets can be adjusted independently in one-degree increments and the resulting arc can vary from 0° to 45°. (See “Raster Setup Menu” on page 2-37. T op offset set at 0° (22.5° from perpendicular beam )
in .
cm
20
50
40
M axim um high density range
30 10 20
M axim um low density range
10
MS-7180
0
0
10
20 10 30
B ottom offset set at 0° (22.5° from perpendicular beam )
40
R ange in .
0
10
20
30
40
50
20
50
H eight cm
0
10
20
30
40
50
60
70
80
90
100
110
120
Figure 1-3 MS-7180 Raster Height
Raster Height. If raster arc and label ∅ range are known, raster height can be RH = ( 2 × ScanRange ) tan ----
2 derived by the following formula where Ø 1 is raster arc in degrees: Raster Arc. If raster height and label range are known, the raster arc can be derived by using the following formula where RH is raster height:
RH ∅ = 2 • atan ---------------------------------------- 2 × ScanRange
1. Raster Height and Raster Arc formulas assume a straight-on symmetrical arc.
MS-7100/7180 Industrial Scanner User’s Manual
1-5
1–Setup and Inst.
4 Determine Raster Height and Arc
Page 16
1–Setup and Inst.
Chapter 1
Setup and Installation
5 Calculate Number of Scans
To ensure reliable scanning, we recommend that you apply a minimum of five scans to each label. Use the formulas below to calculate the number of scans that your label will receive. If the number of scans you derive from one of these calculations is less than the minimum for your application, plug in the minimum number of scans and solve for another parameter that might be changed, such as label speed or scans per second (SPS).
See Appendix C, “Orientation,” on page A-6 for explanation of ladder, picket fence, and label characteristics.
MS-7100 Ladder Calculation LH
------ LS × SR – 3 = number of complete scans
1
Where LH = Label Height, LS = Label Speed, and SR = Scan Rate.
Example: If LH = 1, LS = 10, and SR = 1000, then the number of scans will equal 97.
Picket Fence Calculation SW – LL ) (------------------------× SR – 3 = number of complete scans
LS
1
Where SW = Scan Width, LL = Label Length, LS = Label Speed and SR = Scan Rate
Example: If LL = 2, LS = 10, SW = 8, and SR = 1000, then the number of scans will equal 597.
Angled Picket Fence Calculation The number of complete scans for angled picket fence is calculated the same as that for picket fence, with the exception that the scan width is shortened in proportion to scan tilt.
1. The -3 component is added to allow for AGC acquisition and for incomplete first and last scans. This applies only if the calculation in the brackets is 3 or more. If it equals 2, then subtract only 1, giving 1 good scan.
1-6
MS-7100/7180 Industrial Scanner User’s Manual
Page 17
Calculate Number of Scans
Ladder Calculation Ladder scanning is rarely done with raster scanners and when it is, it is generally done with a stop and go label. In such a situation the number of scans is equal to the scan rate times the number of seconds the label pauses under the raster image (adjusted by the ratio of raster height to label height).
Picket Fence Calculation For picket fence raster scanning, number of scans (NS) is arrived at by first solving for sweeps per second (SPS). Sweeps per Second (SPS) is the user-programmable number of raster sweeps that transpire in a second. A sweep is defined as a single pass, up or down, describing the raster image. Sweeps per second should generally be as few as possible in order to maximize the number of scans applied to a given label and to minimize wear on the raster parts and vibration to the scanner. The formula for finding Sweeps Per Second (SPS) is as follows:1 2 × LS SPS = ------------------------( SW – LL ) Since SPS can only be entered into the software (see “Raster Setup Menu” on page 2-37) as whole numbers, round off fractions of SPS to the next higher number, for example enter 0.4 as 1 and 3.5 as 4. Number of Scans (NS) be calculated by the following formula:2 LH × SR – 3 NS = -----------------------RH × SPS Example: If SW = 10, LL = 2, and LS = 2, then SPS will equal 0.5. Since 0.5 is less than one, we will assign a value of one in the Sweeps per Second option as described in “Raster Setup Menu” on page 2-37 and in the NS formula which (with LH = 1, SR=400, RH = 10, and SPS = 1) calculates out to 37 complete scans. 1. The number 2 in the SPS formula is a constant that doubles the number of sweeps to ensure that each label receives two full raster sweeps. 2. The -3 component is added to allow for AGC acquisition and for incomplete first and last scans. This applies only if the calculation in the brackets is 3 or more. If it equals 2, then subtract only 1, giving 1 good scan.
MS-7100/7180 Industrial Scanner User’s Manual
1-7
1–Setup and Inst.
MS-7180
Page 18
1–Setup and Inst.
Chapter 1
Setup and Installation
6 Attach Cabling
28-pin host connector
9-pin trigger connector
9-pin p ower conn ector
The scanner (figure 1-4) has three I/O connectors on the rear panel which accept circular, twist-lock, sealed socket connectors. The center 9-pin trigger connector is covered with a removable dust cap. A connector kit (P/N 98-200003-01) is Figure 1-4 Rear Panel included with your scanner. The kit contains a 9-pin socket connector kit (P/N 200002-01), a 28-pin cable connector kit (P/N 98-200001-01), and related pins, clamps, screws, and dust seals. Use the 28-pin connector kit (P/N 98-200001-01) as part of your host cable assembly for connection with the 28-pin socket connector. (See table 1-3 on page 1-9.) Use the 9-pin socket connector (P/N 98-200002-01) to mate with the 9-pin power connector (see “Power Connector” on page 1-12) or if desired, with the 9-pin trigger connector (see “Trigger Connector” on page 1-11). Note: The 9-pin cable connector kit (P/N 98-200002-01) will mate with either the power connector or the trigger connector. Under ideal conditions, maximum cable lengths can meet the distances shown in table 1-2. However, since cable lengths and sizes are dictated by local conditions such as wire size, shielding, grounding, extraneous signal noise, etc., maximum cable distances will vary.
Table 1-2 Cable Distances Cabling
Maximum Distance
RS-232 Scanner to Host
50’ (15.2 m)
RS-422 Scanner to Host
4000’ (1219 m)
RS-485 Multidrop Trunk
4000’ (1219 m)
RS-485 Multidrop Drop
10’ (3 m)
Several pins are repeated on different connectors. For example, you can apply power optionally through the host or trigger connector, as well as the power connector. You can also use pins 7 and 9 of either the trigger or power connectors to route current through internal relay contacts which open or close according to user-determined conditions (a noread, a match, or a mismatch). The same pulse that drives this internal relay sends a TTL pulse (high or low) to pin 6 on the host and pins 8 of both the trigger and power connectors. If no data is decoded, a noread pulse is output to pin 6 of the host connector. (See “Relay Settings” on page 2-32.)
1-8
MS-7100/7180 Industrial Scanner User’s Manual
Page 19
Attach Cabling 1–Setup and Inst.
Host Connector. The host connector is a 28-pin circular twist-lock connector as shown in figure 1-5 (Amp CPC series) that mates with a supplied 28-pin socket connector (P/N 98-200001-01). It allows the scanner to be connected to a host, a concentrator, or other communications device such as a PLC (programmable logic controller), a monitor, a PC, a relay, a diverter, an alarm, etc.
1
3 8
4 9
14
15
20
21
25 26
28
Figure 1-5 Host Connector Pins 6, 8, and 25 (table 1-3) can be used to drive a small relay to operate an alarm, diverter, etc. A pulse will be sent to pin 8 at the occurance of any noread. Outputs to pins 6 and 25 are programmable (see “Relay Settings” on page 2-32). You can also control voltage level (“Output Polarity” on page 2-33) and duration of pulses (“Output Pulse Width” on page 2-33) for all three pins (6, 8, and 25). Table 1-3 Host 28-pin Connector Pin Assignments
Pin
Function
Pin
Function
1
Chassis ground
15
TXD + (RS-422/RS-485)a
2
Transmit data (RS-232)
16
TXD – (RS-422/RS-485)
3
Receive data (RS-232)
17
Reserved
4
Request to send (RS-232)b
18
Aux transmit data (RS-232)
5
Clear to send (RS-232)
19
Aux receive data (RS-232)
6
Relay--output #1c (see page 2-32)
20
Power ground
7
Signal ground (RS-232)
21
RXD + (RS-422/RS-485)
8
Noread Output (see page 2-17)c
22
RXD – (RS-422/RS-485)
9
+5 VDC out (100 mA max.)
23
Reservedb
10
Trigger input (0 VDC to +24 VDC)
24
Reservedb
11
+12 VDC out (50 mA max.)
25
TTL--output #2c (seepage 2-33)
12
–12 VDC out (20 mA max.)
26
Default config. (see page A-10)
13
Signal ground
27
New Master (see page 2-34)
14
Power input (10 to 28 VDC unreg.)
28
CPU master resetd a. See your multidrop manual for multidrop cabling and termination requirements. b. The default communications mode does not support pin 4 (RTS). If RTS and CTS are not required by the host port, pins 4 and 5 should not be wired as the results will be unpredictable. c. Source or sink 4 mA. d. Bringing pin 28 to ground resets the CPU, clears all buffers, and restores all parameters that have been saved to nonvolatile memory.
MS-7100/7180 Industrial Scanner User’s Manual
1-9
Page 20
1–Setup and Inst.
Chapter 1
Setup and Installation Figure 1-6 shows two minimum host connections for RS-232 communications using the supplied 28-pin socket connector shown on the left. 28-pin Connector to DB-25 DTE Connection
28-pin Connector to DE-9 DTE Connection
Scanner
Host
Scanne r
Ho st
T ra nsm it
2
2
Transmit
Transmit
2
2
Re ceive
3
3
Receive
Receive
3
3
Transmit
Signal G rn d
7
7
Signal Grnd
7
5
Signal Grnd
Signal Grnd
Receive
Figure 1-6 DTE Host Connections
Caution: Do not use a host cable with more wires connected than are required for the application. The host connector of the scanner has many outputs that could cause damage or interfere with normal operation if connected and improperly used. Note: All Microscan products are configured as DTE at the host connector when in RS-232 operation.
1-10
MS-7100/7180 Industrial Scanner User’s Manual