Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 13 of 15

MS-710 Scanner User's Manual, pages 121 to 130

Pages 121 to 130 of 145

The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-710

Page 121

Troubleshooting Table A-5 Troubleshooting

Problem

Possible Cause

MS-sensor display- Reflectance Threshold or ing incorrect error Minimum Label Transitions messages set incorrectly

“Bad bar code” message

Poor bar code quality or incorrect label position. “No bar code” mes- No label is present. sage “No object” No object is present. message

Solution See “MS-sensor Parameters” on page 240. Minimum Label Transitions determines what the sensor will recognize as the lowest setting for a label; therefore, it should be set a few numbers less than the smallest value displayed during the extended decode rate test for an object with a label. Reflectance Threshold compares the reflectivity of empty space versus that of an object; therefore, the object must have a greater reflectivity than empty space for the sensor to respond accurately. Reposition label or test with a label that is known to be good. See “MS-sensor Parameters” on page 240. See “MS-sensor Parameters” on page 240.

Appendices

MS-710 Scanner User’s Manual

A-17

Page 122

Appendix H, Using the IB-105 P/N: 99-420001 The IB-105 is a separately sold item that provides additional functionality to the MS-710. Specifically:

• Default switch

• A normally open relay

• RTS/CTS

• RS-485 Multidrop

• New master switch

• RS-232/RS-422 Mode switch

• Aux port

• Power switch The IB-105 is available in five options (see Table A-11, “IB-105 Options,” on page A20).

Mechanical

Environmental

Length: 4.5 in. (114.3 mm) Width: 3 in. (76.2 mm) Height: 1.5 in. (38.1 mm)

Operating Temperature: 0 to 50°C Humidity: 90% @ 40°C maximum

Electrical

Communications

Supply Voltage Input: Regulated +5 VDC @ 20 mA Maximum ripple: 200 mV p-p with MS-710 +5 VDC @ 500 mA

RS-232, RS-422, RS-485

5

1

Trigger Connector

6 4

3

2

1

3

Power Connector

4

5

2

D ef ault S witch

IB -1 0 5

Appendices

NEW M AS T E R

T RIG G E R

PO W E R

S C AN NE R

Figure A-13 Front of IB-105

A-18

MODE S W IT C H

RS -2 3 2

RS -4 8 5 /4 2 2

Figure A-14 Back of IB-105

MS-710 Scanner User’s Manual

Page 123

Using the IB-105 Table A-9 25-pin D-sub Host Connector

Table A-6 6-pin Trigger Connector Pin a

Function

Pin

Trigger in to pin 9 of scanner connector

1

2

Relay contact normally open (up to 1watt)

2

Host RS-232 TXD (RS-232)

3

VCC (+5V)

3

Host RS-232 RXD (RS-232)

4

VBB (+12V, if using Microscan’s standard object detectora)

4

5

Ground

Host RS-232 RTS or under software control aux RS-232 TXD, or RS-485 transmitter enable (out)

6

Relay common

5

Host RS-232 CTS or under software control aux RS-232 RXD (in)

6

Relay-2 output from pin 14 of scanner connector.

7

Signal ground

8

Relay-1 output from pin 7 of scanner connector.

P/N 99-440001-03

Table A-7 15-pin Scanner Connector Pin a

Function

1

Function

Chassis ground

9

VCC (+5V)

10

Trigger input; same as pin 1 of trigger connector

11

Default configuration pin goes to pin 8 of the scanner connector and the default switch NC

1

+5 VDC (in)

2

Transmit data (RS-232) (out)

3

Receive data (RS-232) (in)

4

Signal ground (RS-232)

5

NC

12

6

RTS (5V only)

13

Host RS-422/RS-485 (+in)

7

Relay-1 Driver (out). Can sink 10 mA and source 2 mA.a

14

Host RS-422/RS-485 (–out)

8

Default configuration (in)

15

Relay contact normally open (up to 1watt) (common with pin 17)

9

Trigger (in) from 3V to 24V

10

CTS (5V only)

11

NC

16

Host RS-422/RS-485 (–in)

17

Relay contact normally open (up to 1watt) (common with pin 15)

18

NC

12

New master (in)

13

Chassis ground

19

Host RS-422/RS-485 (+out)

14

Relay-2 Driver (out). Can sink 10 mA and source 2 mA.

20

NC

21

NC

15

NC

22

Ground

23

NC

Relay-1 output also causes closure of an isolated relay between pin 15 and pin 17 of the IB-105 host connector.

Table A-8 5-pin Power Connector Pin

Function

1

Signal ground

2

Chassis ground

3

+5 VDC

4

NC

5

NC

24

NC

25

New master input to pin 12 of the scanner connector and new master button

Table A-10 6-pin LAN (RJ11) Connector Pin

Function

1

Chassis ground

2

RS-422/485 (+in)

3

RS-422/485 (–in)

4

RS-422/485 (+out) RS-422/485 (–out)

6

Chassis ground

MS-710 Scanner User’s Manual

Appendices

5

A-19

Page 124

Table A-11 IB-105 Options P/N 99-420001-XX

Description

–01

RS-232 with RTS/CTS or RS-485

–02

RS-232 with RTS/CTS or RS-422

–03

RS-422 with Aux RS-232 or RS-232

–04

RS-422 (MS-710) to RS-232

–05

RS-422 LAN to RS-232 converter

Internal Dip Switches 8

7

6

5

4

= ON

3

2

1

= OFF

The IB-105 routes signals between the scanner and other devices. It has the following connectors and switches:

New Master Switch Used in match code operations to indicate that the next label will be read as the new master label. Momentarily press the switch to activate it.

Trigger Connector Connects to an object detector.

Internal Relay The IB-105 uses the scanner’s relay-1 signal to drive a one watt internal relay that connects pin 2 with pin 6 on the trigger connector and pin 15 with pin 17 on the host connector. The relay contacts are closed when relay-1 (pin 7 of the scanner connector) is high. (See tables A-6, A-7, A-8, and A-9 for pinouts.) These contacts are isolated from ground to prevent unwanted ground currents.

Default Switch Provides a convenient way to restore factory configuration settings to the scanner. This switch is recessed to prevent accidentally defaulting the scanner. For default instructions, see Appendix E, “Defaulting the Scanner” on page A-10.

Power Switch Connects the +5V supply (pin 3 of power connector) to the IB-105.

Appendices

Power Connector Designed to accept the standard +5V Microscan power supply. Chassis ground must be properly connected for the IB-105 and scanner to pass all regulatory requirements (FCC, CE, CISPER-22).

A-20

MS-710 Scanner User’s Manual

Page 125

Using the IB-105 Mode Switch Used in options -01 and -02 to toggle the host port between RS -232 and RS-485 or between RS-232 and RS-422, respectively. Options -03 and -04 require that the Mode switch be pushed IN for proper operation.

25-pin (host) Connector The 25-pin (host) connector is similar to the MS-3000 host connector; therefore, applications that were set up for the MS-3000 will work with the IB-105. The only exception is the addition of relay contact pins 15 and 17 of the 25-pin host connector that are in parallel with pins 2 and 6 of the trigger connector. Internally the IB-105 adds RS-232 levels to the RTS and CTS signals on the 25-pin (host) connector. These pins are alternately used for the second RS-232 port depending on the scanner’s configuration.

RS-485/422 (LAN) Connector The RS-485/422 (LAN) connector is pinned out the same as the MS-3000 to make it compatible with the Microscan network. See Table A-10 for pinouts.

OPTION -01: RS-232 with RTS/CTS to RS-485 or Second RS-232 Serial Port Use the Mode switch to toggle the host port between RS-232 and RS-485. • When the Mode switch is OUT the RS-232 signals go through to the 25-pin (host) connector. Scanner

RS-232

IB-105

RS-232

Host

• When this switch is IN the IB-105 takes RS-232 signals (TXD, pin 2, RXD, pin 3) and converts them to RS-485 levels. The RS-485 levels are present at both the RS-485/ 422 (LAN) connector and the 25-pin (host) connector. (See tables A-6, A-7, A-8, and A-9 for pinouts.) Scanner

RS-232

RS-485

Host

RS-485

LAN

IB-105

Note: In this mode the scanner must be set up for Multidrop communications. Note: The second RS-232 TXD pin (pin 4 of the host connector) is not available in this mode.

Appendices

MS-710 Scanner User’s Manual

A-21

Page 126

OPTION -02: RS-232/422 with RTS/CTS or Second RS-232 Serial Port Use the Mode switch to toggle the host port between RS-232 and RS-422. When the Mode switch is OUT, the RS-232 signals go through to the 25-pin (host) connector. Note: The second RS-232 TXD pin is available in this mode. Scanner

RS-232

IB-105

RS-232

Host

• When the Mode switch is IN, the IB-105 takes RS-232 signals (TXD, RXD) and converts them to RS-422 levels. The RS-422 levels are present at both the RS-485/422

Scanner

RS-232

IB-105

RS-422

Host

RS-422

LAN

(LAN) connector and the 25-pin RS-232 connector. See page A-19 and page A-19 for pinouts.

OPTION -03: RS-422 with Second RS-232 Serial Port on Pins 2 and 3 In this configuration the Mode switch must be IN for proper operation. This mode is the same as option -02 except that the second serial port (aux) is present on pins 2 and 3 of the 25-pin (host) connector. This allows a standard RS-232 cable to connect to the second serial port. Scanner

RS-232

IB-105

RS-232

Aux

RS-422

LAN

OPTION -04: RS-422 (MS-710) to RS-232 In this configuration the Mode switch must be IN for proper operation. This configuration has the same features as the previous configurations except that the Scanner connector pins for TXD, RXD, CTS, RTS are used by the MS-710 for 422 communications. So to connect an RS-232 terminal to the MS-710, the IB-105 con-

Appendices

Scanner

RS-422

IB-105

RS-232

Host verts these signals to RS-232 levels and back. Pins 2 and 3 on the 25-pin (host) connector are the only communications pins that are active in this configuration.

A-22

MS-710 Scanner User’s Manual

Page 127

Using the IB-105 OPTION -05: RS-422 LAN to RS-232 Terminal 1 In this configuration the Mode switch must be IN for proper operation. This is a special configuration to convert RS-422 signals back to RS-232. The main purpose for this configuration is to use two IB-105’s, one to convert the scanner communications to RS-422 and one to convert these signals back to RS-232 (this configuration) for long distance communications (up to 4000 feet).

Scanner

RS-232

IB-105 (-02 or -04)

RS-422

IB-105 (-05)

RS-232

Host

See Table A-9 and Table A-10 for pinouts. The LAN cable pinout must be as follows: LAN RJ-12 cable #1 IB-105 RS-485/422 Connector

#2 IB-105 RS-485/422 Host Connector

1

1

2

2

3

3

4

4

5

5

The signal routing is from the LAN connector to the LAN connector. The scanner and trigger connector are not used in this configuration.

MS-710 Scanner User’s Manual

A-23

Appendices

1. Access to the configuration menus of a scanner that is in a polled mode can be forced (without defaulting) by sending the <D> command from an auxiliary terminal via the auxiliary RS-232 port.

Page 128

Appendix I, MS-Sensor Note: The MS-sensor is an optional FIS feature. The MS-sensor is a patented specular sensor that interprets reflected light from the laser beam. Once adjusted to your environment, it indicates why the scanner might fail to decode a label within the triggered read cycle and outputs the appropriate message to you. The following three conditions are possible: • the object’s bar code is defective (you receive a bad bar code message) • there is no bar code on the object (you receive a no bar code message) • there is no object (you receive a no object message) To properly configure the MS-sensor, you must first enter the extended decode rate test to view the readouts for reflectance (REF) and transitions (TRANS), the number of label bar and space transitions. These readouts are the basis for configuring Reflectance Threshold and Minimum Label Transitions, which exclusively affect the MS-sensor’s operation (see page 2-40 for menu selection or page 3-20 for serial commands). Note: Prior to beginning the extended decode rate test, make sure that the lighting conditions are equivalent to what they will be during normal operations and that the sensor’s field of view is clear of all objects that are not to be sensed. a) To begin the extended decode rate test, enter <Ce>. The extended decode rate test also displays decode rate and label data (if any exists) as well as reflectance and transition readings. Reflectance Threshold Number of Label Bar & Space Transitions

Label Information Decode Rate per Second

347 Decodes/Sec 0071486026624 REF= 488 Decodes/Sec 0071486026624 REF= 488 Decodes/Sec 0071486026624 REF= 447 Decodes/Sec 0071486026624 REF=

0 TRANS= 38 0 TRANS= 37 0 TRANS= 37 0 TRANS= 33

Appendices

* Example shows output when Postamble is enabled and defined as a carriage return and a line feed.

As shown in figure A-15 on page A-25, the results for Minimum Label Transitions and Reflectance Threshold is sensed from directly in front of the scanner at an optimum detection range of 3 inches for diffused objects and 5 inches for specular objects.

A-24

MS-710 Scanner User’s Manual

Page 129

MS-Sensor

Scan Width cm 20 in.

15

10

5

5

0 0

MS-sensor's specular detection area

5

10

15

20

5 Scan Beam 25

10

20

Specular Objects Diffused Objects

15 5 10 5

MS-710

Scan angle equals 60 degrees

0

0 cm in.

Range

Figure A-15 MS-sensor Range b) Determine the setting for Reflectance Threshold (the minimum reflective level at which an object is detected) by selecting a value that is one or two numbers greater than the value posted next to REF when nothing is in the scanner’s beam.1 c) Determine the setting for Minimum Label Transitions (each bar and space along a bar code label is counted as a “label transition”) by testing the TRANS readout for several objects with labels and then selecting a value that is one or two numbers less than the smallest value that was posted next to TRANS during the test period. d) Enter <J> to exit the extended decode rate test. e) Set Minimum Label Transitions and Reflectance Threshold (see “Setup Menu” on page 2-38) to the numbers you have selected during the extended decode rate test. f) Activate the triggering event; the scanner will either output the label’s data or the sensor will display a message signifying that the bar code label is defective, that no label is present, or that no object is present.

MS-710 Scanner User’s Manual

A-25

Appendices

1. Reflectance can also be modified by sending the <KQoffset> test command which samples 50 scans for the highest reflectance value and adds a user-defined offset to this value.

Page 130

Start

Trigger Event

Scans until End of Read Cycle

Does the scanner decode the label?

Yes

No

Is MS-sensor Status enabled?

No

Scanner outputs the noread message

Yes

Scanner outputs the bad label message (if enabled)

Yes

Scanner outputs the no label message (if enabled)

Yes Are the number of transitions greater than the user defined value? No

Is the reflectance greater than the user defined threshold? No

Appendices

Scanner outputs the no object message (if enabled)

Figure A-16 MS-sensor Flowchart

A-26

MS-710 Scanner User’s Manual

Done