Page 111
ASCII Table
Appendix C, ASCII Table Table A-4 ASCII Table with Control Characters
Hex
Mne
Ctrl
Dec
Hex
Ch
Dec
Hex
Ch
Dec
Hex
Ch
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
^@ ^A ^B ^C ^D ^E ^F ^G ^H ^I ^J ^K ^L ^M ^N ^O ^P ^Q ^R ^S ^T ^U ^V ^W ^X ^Y ^Z ^[ ^\ ^] ^^ ^_
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
SP ! " # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
96
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ ∆
MS-710 Scanner User’s Manual
97 98
99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
Appendices
Dec
A-7
Page 112
Appendix D, Orientation If the bar code label bars are parallel to the direction of travel, as shown in figure A-5, the label is said to be in a ladder orientation; if the bars are perpendicular with the direction of travel, the label is said to be in a picket fence orientation (figure A-6).
Ladder Orientation In general, depending on label size and speed, ladder orientation is preferable because different portions of the label are scanned as the label goes by. In addition, label placement is not as critical. As shown in figure A-5, a label can be successfully read if fully placed (including quiet zones) anywhere within the readable portion of the scan line.
Direction of label travel
Scan line (full width)
Label placement area
Label
Picket Fence Orientation
Figure A-5 Ladder Orientation
Unlike ladder, picket fence allows only a small portion of the entire label to be scanned. As a result, labels must be of good quality since even slight label imperfections such as extraneous ink, voids, etc., can cause misreads or non-reads. One advantage of the picket fence over the ladder orientation is in the area of label speed. In ladder mode, the label travel distance is the height of the bar code; in picket fence mode, the label can be read while it travels the full distance of the scan width.
Direction of label travel
Label placement area
Scan line Figure A-6 Picket Fence Orientation
Appendices
Note: Either ladder or picket fence can be rotated without losing its orientation, provided that the label’s direction of travel does not change in relation to the scan line.
A-8
MS-710 Scanner User’s Manual
Page 113
Orientation Angled Picket Fence Orientation The problems associated with picket fence can be minimized by slightly tilting the scan line (figure A-7). This allows a larger portion of the label to be scanned and increases the label placement area by “simulating” the ladder orientation. This of course is impractical with a short bar code height. Angled picket fence is recommended only where the bar code is reasonably tall and the label speed is not too fast in relation to the scan field width, since angling the label will reduce the number of scans on the label.
Direction of label travel Scan line Label Label placement area Scan width
Figure A-7 Angled Picket Fence Orientation
Object Detector When an object detector is used, it is set up so that its beam will bounce off the approaching object and the resulting pulse will be sent to the scanner to begin the read cycle. Typically, a detector is positioned so that it will detect the presence of an object before the object’s label can be scanned by the scanner.
Label Detector Scan beam Direction of label travel
Scanner
An object detector is mounted in almost any position relative to the object as long as (1) the object passes within range of Figure A-8 Detector Orientation the detector and (2) direct or reflected light from the detector does not interfere with the scanner’s reception. As the item continues to move down the line, its label moves into the scanner beam and is read by the scanner.
Appendices
MS-710 Scanner User’s Manual
A-9
Page 114
Appendix E, Defaulting the Scanner Defaulting the scanner resets all scanner configuration parameters except Scanner Type, SPS, and Gain Adjustment to their original default values. These values are saved to NOVRAM for power-on by entering the <Zp> command (Save Scanner Type, SPS, and Gain for Power-on).
RAM NOVRAM
ROM
Defaulting is necessary if: • You wish to quickly restore default settings to the configuration program after making some temporary changes. • Communications between the scanner and another device are interrupted because of incompatible settings (for example, a terminal is set to communicate at 9600 baud, but the scanner is configured at 38.4K baud). • The scanner has been assigned a polling address and you wish to access the scanner’s menu. Note: Power must be available to the scanner during all default procedures.
Software Default The software default is done by entering the <Zd> (Restore/Save Default Configuration for Power-on) command.
Hardware Default If using an IB-105 adapter box, you can default the MS-710 scanner by inserting the end of a straightened paper clip into the IB-105’s default switch. (See “Using the IB105” on page A-18.) 1. Connect scanner and IB-105 to host and apply power to the scanner and IB-105. 2. Momentarily insert probe into the IB-105 default switch. Listen for a series of short beeps.
Appendices
3. Within 3 seconds, pull paper clip out slightly and re-insert. A longer beep should be heard. If not, repeat the process.
A-10
MS-710 Scanner User’s Manual
Page 115
Number of Scans
Appendix F, Number of Scans To ensure reliable scanning, apply a minimum of five scans to each label. Use the formulas below to calculate the number of scans that your label will receive. For definitions of terms, see inset on page A-12. If the number of scans you derive from one of these calculations is less than the minimum for your application, plug in the minimum number of scans (5) and solve for another parameter that might be changed, such as label speed or scans per second.
Ladder Calculation 1 LH
------ LS × SR – 3 = number of complete scans
Where LH = Label Height, LS = Label Speed, and SR = Scan Rate.
Example 1:
Direction of label travel
LH = 1 inch LS = 10 inches per second SR = 500 scans per second
Scan Line
1 ---- 10 × 500 – 3 = 47 complete scans Figure A-9 Ladder Orientation
Picket Fence Calculation SW – LL ) (--------------------------× SR – 3 = number of complete scans 1
LS Where SW = Scan Width, LL = Label Length, LS = Label Speed and SR = Scan Rate
Direction of label travel
Example 2: LL = 2 inch (including quiet zones) LS = 10 inches per second SW = 8 inches SR = 500 scans per second
Figure A-10 Picket Fence Orientation
1. The -3 component in the formula is included to allow for AGC acquisition, an incomplete first scan, and an incomplete last scan. This applies only if the number inside the parentheses equals 4 or more. If the number equals 3, then only subtract 2 to derive 1 good scan. MS-710 Scanner User’s Manual
A-11
Appendices
8 – 2) (---------------× 500 – 3 = 297 complete scans 10
Scan Line
Page 116
Angled Picket Fence Calculation Direction of label travel
The number of complete scans for angled picket fence is calculated the same as that for picket fence, with the exception that the scan width is shortened in proportion to scan tilt.
Scan Line
Figure A-11 Angled Picket Fence Orientation
Definitions Scan Rate (SR) is the number of scans per second that a given scanner is capable of emitting. Scan Width (SW) (picket fence formula only) is the width across the scan beam, at a given distance from the scanner, in which a label can be read. Label Speed (LS) is the distance per second that a label moves as it travels through the scan lines.
Label l en g t h
Label Length (LL) (picket fence formula only) is the length of the longest printed label to be read plus the length of the quiet zones (figure A-12). Label Height (LH) (ladder formula only) is a measurement of the height of individual bars (figure A-12).
Label height
Quiet zones
Figure A-12 Label Dimensions
Note: Be sure to use a common unit of measurement when gathering data on scan width, label speed, label length, and label height.
Improving the Number of Scans 1. After changing any of the parameters described in this section, 2. If applicable, recalculate the number of scans. 3. Repeat step 9, “Test Decode Rate with Moving Label,” on page 1-10. 4. Compare the new decode rate results with those obtained earlier.
Appendices
Scan Rate Scan rate is a function of motor speed and is adjustable in the Scanner Setup menu from 300 to 550 scans per second. Default speed for both scanners is 500 scans per second. A slower scan rate may allow greater label range and/or higher decode rates, but at the cost of fewer scans per label. To adjust the scan rate (motor speed), select Scanner Setup menu.
A-12
MS-710 Scanner User’s Manual
Page 117
Number of Scans After making changes, repeat “Number of Scans” on page A-11 and step 9, “Test Decode Rate with Moving Label,” on page 1-10.
Range Adjusting the label’s range, if possible, is one of the quickest and most effective ways to improve decode rates. However, in some applications you may need to select a less than optimum range, or one that is beyond the fringes of the ranges listed in table A-1 on page A-3. After making changes, repeat “Number of Scans” on page A-11 and step 9, “Test Decode Rate with Moving Label,” on page 1-10.
Scan Width Increasing scan width will increase the number of scans in a picket fence oriented application. Scan width is linked with scan range (as shown in table A-1 on page A3) and changing one will usually require a change in the other. After making changes, repeat “Number of Scans” on page A-11 and step 9, “Test Decode Rate with Moving Label,” on page 1-10.
Label Speed Applies to both picket fence and ladder oriented labels. If your application allows it, label speed (the time in seconds that a label is fully within the scan width of the scanner) is an effective way to alter the number of scans. After making changes, repeat “Number of Scans” on page A-11 and step 9, “Test Decode Rate with Moving Label,” on page 1-10.
Label Dimensions, Label Density, and Label Ratio Not usually an option in most applications, but changes to label parameters can affect number-of-scan calculations and possibly decode rates. If your application allows it, shortening the length of a picket fence label means the label will be in the scan range longer and hence receive a greater number of scans. Increasing the height of a ladder label means it will receive more scans. Changing label density and/or bar code ratio is another way ranges, decode rates, etc. can be altered. After making changes, repeat “Number of Scans” on page A-11 and step 9, “Test Decode Rate with Moving Label,” on page 1-10.
These adjustments, typically made by qualified technicians, are done from within the Scanner Setup menu (see page 2-39). Changes to tracking will generally have a limited effect on decode rates.
MS-710 Scanner User’s Manual
A-13
Appendices
Gain and Tracking
Page 118
Appendix G, Troubleshooting Operational Tips Do: • Check inputs (label speed, length, height, etc.) to ensure the desired number of scans per label. • Avoid excessive tilt, pitch, and skew of the bar code label. • Check the label for readability by doing a decode rate test. If there is any question about the label's readability, contact your Microscan representative. • After changing any parameter that might affect decode rate, repeat decode rate test. • Clean the scanner window with a clean, dry Q-tip or cotton cloth on a regular basis. Do Not: • Aim the scanner into direct light or sunlight. • Aim the scanner into an external object detector or other light-emitting device. • Obstruct the scanner window with mounting hardware or other objects. • Connect chassis of scanner and host to different ground potentials (see “Electrical Specifications” on page A-5). • Operate the scanner in excessive temperature environments (see “Environment” on page A-2). The MS-710 scanner when used correctly should produce good reads. If not, table A-5 lists some of the more common problems associated with setting up and using the scanner. If you are unable to locate or correct the problem, call your Microscan representative.
WARNING
Appendices
Do not look directly into laser aperture. Laser light can be hazardous to your eyes.
A-14
MS-710 Scanner User’s Manual
Page 119
Troubleshooting Table A-5 Troubleshooting
Problem
Possible Cause
Solution
Getting an “Upload Host cable defective or not Check cable connections and wiring. from Scanner has wired properly (See “Attach Cabling” on page 1-3.) timed out!” mesScanner configuration setReset scanner to default and/or match host sage when clicking tings do not match host's settings with scanner's.page A-10. the Receive from Scanner command. No data or decode Wrong label type Check label configuration settings to be certain rate in decode rate (different label type being that they match the label type being scanned. If test (<C>) scanned than that enabled in label type is in doubt, enable Autodiscriminate All Codes (<P> command). firmware) Ensure that fixed length and check sums, if enabled, are set correctly. Incorrect label range or label See “Consider Read Range and Scan too long to be totally covered Width” on page 1-4. Reposition label and by scan beam. check the decode rate. Poor label quality Try a label that is known to be readable. Excessive ambient light, sun- Shield the bar code and/or scan head to verify light, or strobes that excessive light is not the problem. Object detector or another Remedy by remounting, eliminating interferscanner interfering with reads ence, or shielding. Many object detectors emit pulsed infrared signals that can seriously degrade the decode rate if they shine into the scanner or onto the bar code label when it is being read. Low decode rates Poor label, range, placement, See “No data...” in previous Problem heading. during decode rate etc. Do step 10 on page 1-11. test (<C>)
Appendices
MS-710 Scanner User’s Manual
A-15
Page 120
Table A-5 Troubleshooting
Problem
Possible Cause
Decode rate okay but not getting any output (including noreads) in triggered mode
Object detector not positioned properly End of Read Cycle not properly defined Scanner not triggered when in external mode
Decode rate okay but getting only noread messages in triggered mode
Previous label read, but subsequent label will not read Scanner not entering read cycle in triggered mode (trigger not working)
Ensure read cycle is active during the time the label is in the scan line. Ensure that the proper End of Read Cycle is defined in scanner configuration. Ensure trigger device is operating properly. Do Decode Rate Test <C>. If it reads successfully, the problem is triggering. Scanner not triggered when Ensure that correct serial trigger character is in serial mode entered with start/stop characters (a left angle bracket < (unless redefined) and a right angle bracket >). Label misaligned or reflecting Ensure the label is not excessively skewed, direct laser light tilted, or otherwise disoriented. Ensure the bar code is in the scan line when it is supposed to be. Ensure that the bar code is pitched or skewed slightly so as to avoid specular reflection. Triggering/timeout out of Review triggering and timing. (See the Operasync tion menu on page 2-16.) Object detector or another Remedy by remounting, eliminating interferscanner interfering with ence, or shielding. reads Many object detectors emit pulsed infrared signals that can seriously degrade the decode rate if they shine into the scanner or onto the bar code label when it is being read. Window dirty or obstructed Clean or remove obstruction. Scanner configured in Con- Scan a label that contains different data than tinuous Read 1 Output that of the one being read. Scanner in polled mode Check communications protocol. Proper trigger levels not enabled Trigger circuit not correctly wired
Appendices
Object detector inoperative
A-16
Solution
Ensure that the trigger pulse and the trigger polarity settings are correct. Ensure that the trigger circuit wiring meets the scanner requirements. (See “Attach Cabling” on page 1-3.) Check detector range and sensitivity. Try a detector that is known to be good.