Page 101

Checksum

Checksum Part Number Displays software part number. Associated serial command: <#>

Checksum Displays a four-digit hex number (corresponding to a given firmware version) used to verify a scanner’s EPROM. Associated serial command: <!>

Show Scanner Status Used to display certain operating parameters (NOVRAM, command, and operation status). After sending this command, the scanner immediately responds with <X>, where “X” is an ASCII character between @ and ∆ on the ASCII table. Associated serial command: <?> To interpret the scanner’s status, 1. Look up the ASCII character’s Hex value in the ASCII table on page A-7.

2. Refer to table 4-2 to find the Hex value’s binary conversion. The binary bit digits for “4” equal 0100; the binary bit digits for “D” equal 1101. Hence, the binary conversion of 4D is 01001101.

MS-710 Scanner User’s Manual

Hex Value Digits

Binary Bit Digits 7 6 5 4 3 2 1 0

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1

0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1

0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1

0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1

4-13

4–Utilities

For example, the scanner responds with an <M>, corresponding Hex value is 4D.

Table 4-2 Hex Value to Binary Conversion

Page 102

Chapter 4 3.Compare bit digits with the “Is Status Active?” row in table 4-3 (each bit has a specific meaning) Table 4-3 Finding Scanner Status from Binary Bit Digits 0 1 0 0 1 1 0 1 Bit Location: 7 6 5 4 3 2 1 0 NOVRAM error detectora

Communication error detected

Command received

Command error detected

No =

Motor is spinning; scanner is ready

Is Status Yes = Active?

Scanner is in a read cycle

Scanner Status:

Always set to 1

Binary Code

0 = even Parity 1 = odd

In the example shown in table 4-3, a scanner status request returns an <M> corresponding to 4D hex or 01001101. This means that the scanner’s status is even parity, (skip bit location 6; it will always equal 1), with the scanner not in a read cycle, with the motor spinning and the scanner ready to read, with no NOVRAM error detected, with a communications error detected, with the command not received, and with a

N/A

1

0

0

1

1

1

N/A

0

1

1

0

0

0 a. NOVRAM status is valid only after the first status request following a NOVRAM read or write.

If you send the <?>

The scanner will report:

For example:

After Power-on Whether the (NOVRAM NOVRAM was Read) read correctly the first time the status command was received.

4–Utilities

After Sending a Command

Whether the command was sent correctly.

With the scanner in a triggered mode without a serial or edge trigger present, power–off, then power–on and enter the <?> command. The scanner responds with <@> for a good load or <H> for a bad load. See “NOVRAM error detected” in table 4-3 on page 4-14. With the scanner in a triggered mode without a serial or edge trigger present, enter the <?> command to clear the error flags. Then enter the desired command, <L1> for example. Enter <?> again. The scanner responds with <B> if the command was received, <C> if there was an error in the command, or <F> if there was a serial data error.

After NOVRAM Whether the Write NOVRAM was written correctly.

The scanner responds in the same manner as after power– on (NOVRAM read).

Show Software Status Sends the following in this order: status byte, part number, ROM checksum for both possible lengths of ROM (1 megabyte and 512 bytes), current NOVRAM checksum, and NOVRAM checksum at power up. Associated serial command: <?1>

4-14

MS-710 Scanner User’s Manual

Page 103

Code Type Commands

Code Type Commands (Not in the Utilities Menus.)

Autodiscriminate All Codes Enables the scanner to decode all available bar code types without changing scanner configuration settings. Note: For maximum scanning speed, enable only those bar code symbologies used in the application. Associated serial command: <P>

Code 39 Only Allows only Code 39 labels to be read. Associated serial command: <Q>

Codabar Only Allows only Codabar labels to be read. Associated serial command: <R>

I 2 of 5 Only 4–Utilities

Allows only Interleaved 2 of 5 labels to be read. Associated serial command: <S>

MS-710 Scanner User’s Manual

4-15

Page 104

4–Utilities

Chapter 4

4-16

MS-710 Scanner User’s Manual

Page 105

Appendices A

Contents Appendix A, Scanner Specifications ..................................................A-2 Appendix B, Electrical Specifications .................................................A-5 Appendix C, ASCII Table ...................................................................A-7 Appendix D, Orientation .....................................................................A-8 Appendix E, Defaulting the Scanner ................................................A-10 Appendix F, Number of Scans .........................................................A-11 Appendix G, Troubleshooting ..........................................................A-14 Appendix H, Using the IB-105 ..........................................................A-18 Appendix I, MS-Sensor ...................................................................A-24 Appendix J, Bar Code Symbology ...................................................A-27 Appendix K, Interface Standards .....................................................A-28 Appendix L, Multidrop Communications ..........................................A-29 Appendix M, Glossary of Terms .......................................................A-32

Appendices

MS-710 Scanner User’s Manual

A-1

Page 106

Appendix A, Scanner Specifications Mechanical -- MS-710

Light Source

Length: 3.47” (88.1 mm) Height: 1.32” (33.5 mm)

Type: Laser Diode Output Wavelength: 670 nm nominal Safety Class: CDRH Class II Operating Life: 50,000 hours @25°C (10,000 hours @50°C) Laser Cooling: Thermostatically controlled thermocooler

Width: 2.59” (65.8 mm) Weight: 9 oz. (255 g)

0.53" (1.35 cm)

3.47" (8.81 cm ) 2.50" (6.35 cm )

Scanning Parameters

0.519" (1.32 cm )

1.206" (3.06 cm )

cable

Optional M ounting Holes (2 places) #6-32 x 0.29 deep

2.59" (6.58 cm )

Top center of laser beam output

8 inches (203.2 mm) 0.31 inch (7.87 mm)

(front)

2.59" (6.58 cm )

10 inches (254 mm)

M ounting Holes (2 places) M4.0 x 0.7 - 6g x 3.8 m m deep cable

2.50" (6.35 cm ) 3.47" (8.81 cm )

Code 39, Codabar, Interleaved 2 of 5, UPC/EAN, Code 128 Code 16K, UCC/EAN-128, AIAG, Code 49, Code 93, DX Code, EDP & STK/EDP, MSI Code, Pharma Code, Plessey Code, PDF 417 laser beam 1.10" (2.79 cm )

Protocols Point-to-Point, Point-to-Point w/RTS/CTS, Point-to-Point w/XON/XOFF, Point-to-Point w/RTS/CTS & XON/XOFF, Polling Mode D, Multidrop, User Defined, User Defined Multidrop.

0.18" (0.46 cm ) 1.32" (3.35 cm )

Side View (optional right-angle down) 0.58" (1.47 cm ) 97° (±1°)

Appendices

2.59" (6.58 cm )

laser beam

3.24" (8.23 cm )

Figure A-1 MS-710 Dimensions

A-2

Interface: RS-232, RS-422, and RS-485 Baud Rates: 300, 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K, 76.8K Parity: Odd, Even, None Stop Bits: 1, 2 Data Bits: 7, 8

Code Types

0.54" (1.37 cm )

Side View

0.38 inch (9.65 mm)

Communications

Bottom

1.32" (3.35 cm )

Raster Height 0.10 inch (2.54 mm)

6 inches (152.4 mm) 0.24 inch (6.1 mm) 3.47" (8.81 cm )

0.57" (1.45 cm )

Scan Range 2 inches (50.8 mm)

4 inches (101.6 mm) 0.17 inch (4.32 mm)

1.3" (3.3 cm )

1.40" (3.56 cm )

Primary Mirror Type: Rotating, 10-faceted Scan Rate: 300 to 550 scans per second standard. Scan Width Angle: Typically 60° Optional Raster Mirror Image: 10 raster scan lines over a 2-degree arc (or 0.24 inch raster at 6-inch distance)

Environment Enclosure: IP54 Operating Temperature (inside ambient): 32° to 122°F (0° to 50°C) Storage Temperature: –20° to 158°F (–29° to 70°C) Humidity: Up to 90% (non-condensing) Ambient Light Immunity: • 450 foot candles (indoor: fluorescent, incandescent, mercury vapor, sodium vapor) • 1800 foot candles (soft outdoors)

MS-710 Scanner User’s Manual

Page 107

Scanner Specifications Status Lights Red

5V power is present

Ready

Green

Scanner is ready to read

Good Read

Green

Label is qualified as good

In menu status both green lights will flash on and off.

Optical Characteristics Optics: Coaxial Operating range (depending on label type and size): High Density: 2 to 4 inches Low Density: 2 to 10 inches Right-angle Down: 1 to 8.5 inches Scan width: 7 inches maximum Skew: ±40° maximum Pitch: ±50° maximum Label contrast: 25% min. absolute dark to light differential at 670 nm wavelength The table and graphs that follow show scan widths and read range minimum and maximums for several bar code densities. Table A-1 Range Data

15

10 in.

5

0

5

5

10

15

0

25

Scan an g le typically 60 d eg rees 10

.005" .0075"

5

High Density cm in.

Low Density

MS-710

Range

2 to 3.1” (5.08 to 7.87 cm)

2.1” (5.33 cm)

.0075” (.191 mm)

2 to 4” (5.08 to 10.2 cm)

3.6” (9.14 cm)

15

10 5

5

0 0

5

10

15

.010” (.254 mm)

2 to 6.5” (5.08 to 16.5 cm)

5" (12.7 cm)

.015” (.381 mm)

2 to 7.5” (5.08 to 19.0 cm)

6" (15.2 cm)

.020” (.508 mm)

2 to 10” (5.08 to 25.4 cm)

7” (17.8 cm)

.030” (.762 mm)

2 to 10” (5.08 to 25.4 cm)

7” (17.8 cm)

.040” (1.02 mm)

2 to 10” (5.08 to 25.4 cm)

7” (17.8 cm)

Right-angle Down

.0075” (.191 mm) 1.25 to 4” (3.18 to 10.2 cm)

4" (10.2 cm)

.010” (.254 mm)

1 to 5” (2.54 to 12.7 cm)

5" (12.7 cm)

.015” (.381 mm)

1 to 6” (2.54 to 15.2 cm)

6" (15.2 cm)

.020” (.508 mm)

1 to 8.5” (2.54 to 21.6 cm)

7” (17.8 cm)

.030” (.762 mm)

1 to 8.5” (2.54 to 21.6 cm)

7” (17.8 cm)

.040” (1.02 mm)

1 to 8.5” (2.54 to 21.6 cm)

7” (17.8 cm)

Scan angle typically 60 degrees

MS-710

.015"

4" (10.2 cm)

in.

20

25

.010"

.0075” (.191 mm) 2.5 to 5.5” (6.35 to 14.0 cm)

0

5

.0075"

Low Density

5

Scan Width cm 20

.020", .030", .040"

.005” (.127 mm)

5 10

Figure A-2 Low Density and High Density Scan Range/Width Graph in.

Read Range

15

Range

Maximum Scan Widtha

Narrow-bar-width

10

20

0 cm

High Density

10

20 15 5 10 5 0 cm

0 in.

Range

Figure A-3 Right-angle Down Scan Range/Width Graph

Appendices a

20

5

.015"

Power

Scan Width cm 20

.020", .030", .040"

Statusa

.010"

Luminance

.0075" a

LED

At 500 decodes per second using Code 39 grade A label.

MS-710 Scanner User’s Manual

A-3

Page 108

FIS Options Each MS-710 model is identified by an FIS (final instruction sheet) number that refer to a set of options. The following are the standard options available at this time:

Hardware • Single line / Raster scanning • Straight out / Right angle • Bottom mount / Top mount • Low density / High density • RS-232 / RS-422 and RS-485 • Second relay for noread option • MS-sensor

Software • Wand emulation • Full ASCII code 39 software • Code 49 software • PDF-417 • Extended hold relay • Photo finishing software • MSI software • Long line software • Long label software • Plessy code

Appendices

• Pharma code

A-4

MS-710 Scanner User’s Manual

Page 109

Electrical Specifications

Appendix B, Electrical Specifications Power Supply Requirements: Input +5 VDC ±4% regulated @ 480 mA with 200 mV p-p max. ripple. Table A-2 applies to those FIS options that use RS-232 communications. Table A-3 applies to those FIS options that use RS-422/485 options. The affected pins are 2, 3, 6, and 10. Table A-2 RS-232 15-pin External Cable Connections Pin # 1

Function +5 VDC (in)

Pin # 9

Function Trigger (in) from 3V to 24V

2

Transmit data (RS-232) (out)

10

CTS (5V only)

3

Receive data (RS-232) (in)

11

NC

4

Signal ground (RS-232)

12

New master

5

NC

13

Chassis ground

6

RTS (5V only)

14

Relay-2 Driver TTL (out). Can sink 10 mA and source 2 mA.

7

Relay-1 Driver TTL (out). Can sink 10 mA and source 2 mA.a

15

NC

8

Default configuration (in)

Table A-3 RS-422/485 External 15-pin Cable Connections Pin # 1 a

Function

Pin #

Function

+5 VDC (in)

9

Trigger (in) from 3V to 24V

2

RS-422/RS-485 transmit -

10

RS-422/RS-485 receive +

3

RS-422/RS-485 receive -

11

NC

4

Signal ground (RS-232)

12

New master

5

NC

13

Chassis ground

6

RS-422/RS-485 transmit +

14

Relay-2 Driver TTL (out). Can sink 10 mA and source 2 mA.

7

Relay-1 Driver TTL (out). Can sink 10 mA and source 2 mA.a

15

NC

8

Default configuration (in)

MS-710 only: Relay-1 output also causes closure of a relay in the IB-105 box, accessible through pin 15 of the IB-105 host connector (see Table A-9).

MS-710 Scanner User’s Manual

A-5

Appendices

The MS-710 has a 15-pin internal connector with a standard, hard-wired 3-foot cable terminating in an external 15-pin connector. Connections between the MS-710 and the IB-105 (P/N 99-420001) are shown in Appendix H on page A-18. Since +5 VDC power supply is included in the single cabling assembly, the scanner cable should not exceed 3 feet. RS-232 cabling from the 15-pin connector to the host can be up to 47 feet provided it does not include 5 VDC input.

Page 110

Ground and Shield Considerations Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes. RS-232 signals have a common signal ground (pin 4). Pin 4 is normally connected to pin 13 (chassis ground) in the scanner; however, under certain conditions (e.g., when potential differences exist between power outlet grounds) signal and chassis grounds can be isolated from each other inside the scanner by Microscan technicians.

Noise Interference Noise interference can be minimized if cabling subject to noise interference is twisted and/or shielded or encased in grounded conduit, and the conduit or shielding (“drain” line) is grounded only to earth ground at one end, as shown in figure A-4. The cable has its shield attached to chassis and DC ground internally.

Ground Loops

Adapter

A-6

Power

MS-710

Figure A-4 Grounding Diagram, Scanner-Host

Appendices

Ground loops, signal degradation due to different ground potentials in communicating devices, can be eliminated or minimized by ensuring that both the host, scanner, and their power supplies are connected to a common earth ground.

Host

Shielding Cabling Earth ground

MS-710 Scanner User’s Manual