Page 91
Read Rate
Read Rate Decode (and percentage) rates can vary dramatically due to the angle and location of the label in relation to the scan beam (or scan line, if using a scan head with a moving beam). These tests are very useful in aligning and positioning the scanning device during installation.
Single Label Percent Test Clicking Single Label Percent and Start instructs the scanner to output the percent of decodes and any scanned label data. Associated serial command: <Cp>
Single Label Decodes/Second Test Clicking Single Label Decodes/Sec and Start instructs the scanner to output the decodes per second and label data (if any). The decode rate can vary dramatically due to the angle and location of the label in relation to the scan beam (or scan line, if using a scan head with a moving beam). This test is very useful in aligning and positioning the scanning device during installation. Associated serial command: <C>
Multi-label Percent Test
Associated serial command: <Cm>
Multi-label Decode Rate Test Clicking Multi-label Decode/Sec and Start instructs the scanner to output the decode rate and label data (if any) for multiple labels. Associated serial command: <Cs>
MS-710 Scanner User’s Manual
4-3
4–Utilities
Clicking Multi-label Percent and Start instructs the scanner to output the percentage of scans decoded and label data (if any) for multiple labels.
Page 92
Chapter 4 End Read Rate Test Clicking Stop ends both the Percent test and the Decodes/Second test for both single and multi-label. Associated serial command: <J>
Extended Mode Choosing any of the Read Rate modes along with Extended Mode affects both single and multiple labels. It instructs the scanner to output the transition data along with the data from the latest test command sent. For example, enabling extended mode along with single or multiple decodes per second will cause the decode rate, label data, and transition data to be displayed. Label Information
Reflectance Threshold
Decode Rate per Second
Number of Label Bar
347 Decodes/Sec 0071486026624 REF= 488 Decodes/Sec 0071486026624 REF= 488 Decodes/Sec 0071486026624 REF= 447 Decodes/Sec 0071486026624 REF=
0 TRANS= 38 0 TRANS= 37 0 TRANS= 37 0 TRANS= 33
* Example shows output when Postamble is enabled and defined as a carriage return and a line feed.
Associated serial command: <Ce> after <C>, <Cs>, <C>, or <Cs>
4–Utilities
Note: The <Ce> command has no immediate effect if not preceded by <C>, <Cs>, <C>, or <Cs>.
4-4
MS-710 Scanner User’s Manual
Page 93
Trigger
Trigger Clicking the Setup button will bring up the current trigger character. Next click Send to send the trigger character to the scanner and initiate a read cycle. The results, a good read or noread message, will be displayed on the blank screen below the button. Note: Your scanner must be in a point-to-point protocol for Trigger Setup to work. Note: You can define the trigger character in the Operations menu. Associated serial command: <Ki serial trigger character>
4–Utilities
MS-710 Scanner User’s Manual
4-5
Page 94
Chapter 4
Scanner Enable Laser Scanning Clicking the Laser On button or sending serial command <H> will turn the laser on continuously. Note: Enable Laser Scanning does not relate to Laser On/Off command. Associated serial command: <H>
Disable Laser Scanning Clicking Laser Off will turn the laser off. This feature is useful during extended periods of time when no bar code labels are being scanned or the scanner is being configured. Disabling laser scanning will not affect any downloaded commands to the scanner. Note: Disable Laser Scanning does not relate to Laser On/Off command. Associated serial command: <I>
Motor On Clicking Motor On or sending serial command <KE> turns the spinning mirror and raster mirror motors on (if not already running). Note: Spinning mirror reaches full speed after a short time delay).
4–Utilities
Associated serial command: <KE>
Motor Off Clicking Motor Off or sending serial command <KF> turns the spinning mirror motor off. This command is useful for long idle periods. Associated serial command: <KF>
Output-1 Clicking Output #1 activates the output between pin 7(regardless of Master Label or Output-1 Driver status). Associated serial command: <L1>
4-6
MS-710 Scanner User’s Manual
Page 95
Counters
Counters Counter commands can be a numeric value from 00000 to 65,535. After reaching the maximum numeric limit of 65,535, an error message will be displayed and the counter will automatically rollover and start counting again at 00000. To obtain the cumulative total of counts after the rollover has occurred, add 65,536 per each rollover (the scanner does not keep track of the number of rollovers) to the current count. Note: All counter values will be lost if power is recycled to the scanner or the scanner receives a reset or save command. Clicking Reset for any counter will reset that counter to 0. Clicking Request for any counter will return the current number for that counter.
Noread Counter Clicking Request displays the total number of noreads that have occurred since the last reset. Associated serial command: <N>
Noread Counter Reset Clicking Reset sets Noread Counter to 00000. Associated serial command: <O>
4–Utilities
Trigger Counter Clicking Request displays the total number of triggers since the last reset. Associated serial command: <T>
Trigger Counter Reset Clicking Reset sets the trigger counter to 00000. Associated serial command: <U>
Match Counter (or Good Read Counter) Clicking Request displays the total number of good reads matching the master label MS-710 Scanner User’s Manual
4-7
Page 96
Chapter 4 or, if Master Label is not enabled, the number of good reads since the last reset. This counter is always enabled, but will only work as a match count when Master Label is enabled. If Master Label is not enabled, this counter records the number of good reads. This count can be requested at any time. Associated serial command: <V>
Match Counter Reset Clicking Reset sets the Match Counter to 00000. Associated serial command: <W>
Mismatch Counter Clicking Request displays the message the number of labels successfully read that do not match the master label since the last reset. Associated serial command: <X>
Mismatch Counter Reset Clicking Reset sets the Mismatch Counter to zero.
4–Utilities
Associated serial command: <Y>
4-8
MS-710 Scanner User’s Manual
Page 97
Master Label
Master Label Enable Match Code Type Identical to “Match Code Type,” on page 2-22. Instructs the scanner to compare bar code labels being scanned with a master label and may under certain conditions send out a relay driver signal and update internal counters. If no master label has been entered, every decoded label will be a “mismatch” and will increment the mismatch counter by one. Enable Match Code Type is intended for use when the scanner is in a triggered mode. If the Match Code Type is enabled in the Continuous Read mode, the scanner defaults to Continuous Read 1 Output mode, and the label data must change before the scanner will output data again, unless a timeout, if enabled, occurs. (See “Operation Menu” on page 2-16.) Associated serial commands: <E>
Disable Match Code Type Disables Match Code Type. Associated serial commands: <F>
Store Next Label Scanned as Master Label
Associated serial commands: <G>
Download Master Label Information Downloads master label information into RAM from the host or a terminal. A stored master label will not affect standard operation unless Match Code Type is enabled. The Xs denote alphanumeric data, from 1 to 64 characters. Associated serial commands: <)XXXX)>
MS-710 Scanner User’s Manual
4-9
4–Utilities
If Match Code has been enabled, causes the scanner to read the next bar code label scanned as the master label and stores it in RAM. All subsequently decoded labels are compared against the new master label information. (See “Match Code Type” on page 2-22.)
Page 98
Chapter 4 Request Master Label Information Immediately sends the master label information to the host. To prevent conflicts with outputting label data, first send the <I> command (Disable Laser Scanning (Laser Off)). Associated serial commands: <)>
Delete Master Label Information Deletes master label information that has previously been loaded by either <)XXXX)> Download Master Label Information Command or <G> Store Next Label as Master Label command.
4–Utilities
Associated serial commands: <))>
4-10
MS-710 Scanner User’s Manual
Page 99
Reset
Reset Important: All <A> and <Z> commands must be followed by a one second delay before any operations, commands, or reads can be processed.
Reset Initializes all serial configuration commands in RAM and resets all counters and operating parameters.
<A>
Initialize RAM
Note: Software Reset will reset all counters. You should record all data that you wish to save prior to sending this command.
NOVRAM
ROM
Associated serial command: <A>
Reset/Restore Default Restores the ROM default values to RAM then initializes them. Does not effect Scanner Type, Scans per Second, or Gain Adjustment.
<Ad>
Initialize RAM
Associated serial command: <Ad> NOVRAM
ROM
Reset/Read NOVRAM <An>
Associated serial command: <An>
RAM NOVRAM
MS-710 Scanner User’s Manual
Initialize
4–Utilities
Reads the NOVRAM settings then initializes them to RAM.
ROM
4-11
Page 100
Chapter 4 Reset/Save Parameters for Power-on Allows you to save all configuration command settings to NOVRAM. Numeric counter values and master label data are not saved by this command.1 Associated serial command: <Z>
Restore/Save Default Configuration for Power-on Allows you to restore and save default settings for all but Scanner Type, Scans per Second, and Gain Adjustment to NOVRAM.
<Zd>
RAM ROM
NOVRAM
Note: Power must be available to the scanner during the default procedure.
Defaulting might be necessary after temporary changes or if communications between the scanner and another device are lost or interrupted, or if you are using incompatible equipment (for example, a terminal is set to communicate at 9600 baud, but the scanner is configured at 38.4K baud). Associated serial command: <Zd>
Save Scanner Type, SPS, and Gain for Power-on
4–Utilities
Allows you to save the current settings for Scanner Type,2 Scans per Second, and Gain Adjustment to NOVRAM. Once you send this command, default values can only be recalled if you reenter them individually and then save them again with this command.
<Zp> NOVRAM
RAM ROM
Important: This command will replace the optimized factory setting for Gain Adjustment with your new setting; record and save this setting for future reference prior to sending this command. Associated serial command: <Zp>
1. The <Z> Software Reset/Save Parameters for Power-on command can be executed at least 10,000 times. In normal usage this will exceed the life of the scanner. If frequent changes to the operating parameters are required, it is recommended that the <Z> command be used only when the current configuration has been changed and the changes are to be permanent. 2. Scanner Type should not be changed from its factory setting.
4-12
MS-710 Scanner User’s Manual