Page 81
Code Type Commands Narrow Margins/Symbology ID Format: <Konarrow margins status,symbology ID status> narrow margins status: 0 = Disabled 1 = Enabled symbology ID status: 0 = Disabled 1 = Enabled
Example: To enable Narrow Margins, send <Ko1>.
Autodiscriminate Format: <P> Enables all available symbology types and disables OMR. You may individually disable/ enable each symbology type also. Note: For maximum scanning speed, enable only those symbologies used in the application.
Code Types Status Request
3–Serial Config.
Format: <KW?> Example: Returns status of each command in the group
MS-710 Scanner User’s Manual
3-15
Page 82
Chapter 3
Scanner Output Commands Relay-1 Format: <Kvoutput on,polarity,pulse width,# before output> output on (mode): 0 = Mismatch or Noread 1 = Match (or Good Read) 2 = Mismatch 3 = Noread polarity: pulse width: 0 = Negative Default is 5 (50 ms). 1 = Positive 0 to 255
# before output: Default is 1. 1 to 255
Example: To set Relay-1 to Mismatch and change Pulse Width to 40 ms, and # Before Output to 5, enter <Kv2,0,4,5> or <Kv2,,4,5>.
Relay-2
3–Serial Config.
Format: <Kwoutput on,polarity,pulse width,# before output> output on (mode): 0 = Mismatch or Noread 1 = Match (or Good Read) 2 = Mismatch 3 = Noread polarity: pulse width: 0 = Negative Default is 5 (50 ms). 1 = Positive 0 to 255
# before output: Default is 1. 1 to 255
Example: To set Relay-2 to Mismatch and change Pulse Width to 40 ms, enter <Kw2,0,4> or <Kw2,,4>.
Bar Code Output Format: <Klstatus,when to output> status: 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read when to output: 0 = As Soon As Possible 1 = End of Read Cycle
Example: To set When to Output to End of Read Cycle, enter <Kl3,1>.
3-16
MS-710 Scanner User’s Manual
Page 83
Scanner Output Commands Noread Message Format: <Kkstatus,output> status: noread output: 0 = Disabled Default is NOREAD. 1 = Enabled Any ASCII string up to 7 digits. Example: To enable Noread Message and send the message “FAIL,” enter <Kk1,FAIL>.
Beeper Format: <Kubeeper status,beeper volume> beeper status: 0 = On Good 1 = On Noread beeper volume: 0 = Off 3 = Level 3 1 = Level 14 = Level 4 2 = Level 25 = Level 5
Laser On/Off Format: <KCstatus> status: 0 = Disabled1 = Enabled Example: To enable Laser On/Off, enter <KC1>.
Partial Output Format: <KYstatus,start postion,length> partial output status: 0 = Disabled 1 = Enabled start position: Default is 1 1 to 63 length: Default is 63 1 to 63
Example: To enable Partial Output, set start position to 5, and set length to 6 characters, send <KY1,5,6>.
MS-710 Scanner User’s Manual
3-17
3–Serial Config.
Example: To set the beeper for On Noread and set the beeper volume to Off, enter <Ku1,0>.
Page 84
Chapter 3 Serial Verification Format: <KSserial command echo status,serial command beep status,control/hex output> serial command echo status: 0 = Disabled 1 = Enabled serial command beep status: 0 = Disabled 1 = Enabled control/hex output: 0 = Control 1 = Hex
Example: To enable Serial Command Echo Status and Beep Status, and Hex output, enter <KS1,1,1>
Scanner Output Status Request Format: <KX?>
3–Serial Config.
Returns status of each command in the Scanner Output group.
3-18
MS-710 Scanner User’s Manual
Page 85
Scanner Setup Commands
Scanner Setup Commands Scanner Type Important: Entering the <Zp> command (see “Save Scanner Type, SPS, and Gain for Power-on” on page 4-12) will save the current setting for Scanner Type to NOVRAM. Format: <KPdensity> scanner density type:* 0 = Standard 1 = High Density * The “default” will depend on the type of scanner.
Example: Do not change the scanner density type unless instructed to do so by a Microscan representative.
Scans per Second
3–Serial Config.
Format: <KEscans per second> scans per second (in 10 millisecond increments): Any number from 30 to 55. Default is 50. (500 scans per second.) Example: To set the scanner to 400 scans per second, enter <KE40>.
Auto Gain Control Important: Before saving any changes to Gain Adjustment (see “Save Scanner Type, SPS, and Gain for Power-on” on page 4-12), first record the optimized factory setting for future reference. Format: <KDgain adjustment,AGC samplings> gain adjustment: Default is 45 (nominal). Any number from 10 to 255.
AGC sampling: 0 = Disabled 1 = Leading Edge 2 = Continuous
Example: To set the gain threshold to 40 and the AGC status to Leading Edge, enter <KD40,1,0>.
MS-710 Scanner User’s Manual
3-19
Page 86
Chapter 3 MS-sensor Parameters 1 Format: <KHstatus,minimum transitions,reflectance> MS-sensor status: 0 = Disabled 1 = Enabled number of transitions: Default is 14. Any number from 3 to 255 reflectance threshold: Default is 40. Any number from 0 to 255. Example: To enable the sensor and set Number of Transitions to 20 and the reflectance threshold to 45, enter <KH1,20,45>.
Reflectance Setup Test
3–Serial Config.
Format: <KQoffset> offset: 0 to F (in hexadecimal) Samples 50 scans for the highest reflectance value and adds a userdefined offset to the reflectance threshold value under the MS-sensor Setup reflectance command <KH,,reflectance> above. Example: To change the reflectance offset to add 12 to the reflectance threshold, enter <KQB>.
Bad Barcode Message Format: <KMstatus,message> bad barcode status: 0 = Disabled 1 = Enabled message: Default is BADCODE. Any ASCII string up to 7 characters.
Example: To change the message to “FAULTY,” enter <KM1,FAULTY>.
1. Applies only to FIS options that include the sensor. If you did not order this option, disregard MS-sensor Setup through No Object Message.
3-20
MS-710 Scanner User’s Manual
Page 87
Scanner Setup Commands No Barcode Message Format: <KNstatus,message> no barcode status: 0 = Disabled 1 = Enabled message: Any ASCII string up to 7 characters. Default is NOLABEL.
Example: To change the message to “NOCODE,” enter <KN1,NOCODE>
No Object Message Format: <KOstatus,message> no object output status: 0 = Disabled 1 = Enabled message: Default is MISSING. Any ASCII string up to 7 characters.
Example: To change the message to “VACANT,” enter <KO1,VACANT>.
3–Serial Config.
Scanner Setup Status Request Format: <KU?> Returns status of each command in the group.
MS-710 Scanner User’s Manual
3-21
Page 88
3–Serial Config.
Chapter 3
3-22
MS-710 Scanner User’s Manual
Page 89
Chapter
Utilities
4
Chapter Contents Read Rate ............................................................................................... 4-3 Trigger ..................................................................................................... 4-5 Scanner ................................................................................................... 4-6 Counters .................................................................................................. 4-7 Master Label............................................................................................ 4-9 Reset ..................................................................................................... 4-11 Checksum.............................................................................................. 4-13 Code Type Commands.......................................................................... 4-15
The Utilities menu can be accessed by clicking the Utilities button or selecting from the Utilities pull down menu. You can also send serial command strings to the scanner from a terminal window which you access by Clicking Terminal in ESP. Serial commands are enclosed in brackets <>.
MS-710 Scanner User’s Manual
4-1
4–Utilities
The Utilities menu allows you to send operational commands to the MS-710 to carry out routine operations “on the fly” as distinguished from serial configuration commands that are generally used during your initial setup.
Page 90
Chapter 4 Table 4-1 Summary of Operational Commands
Type Read Rate
Trigger Scanner
Counters
Master Label
4–Utilities
Reset
Checksum
Code Types (not in ESP)
4-2
Cmd
Result
<C> Decode Rate Test for Single Label <Cp> Percentage Rate Test for Single Label <Cs> Multilabel Decode Rate Test <Cm> Multilabel Percentage Rate Test <Ce> Extended Decode Rate Test for Single or Multilabel <J> Exit any Rate Test <char> Serial Trigger Character <H> Enable Laser Scanning (Laser On) <I> Disable Laser Scanning (Laser Off) <KE> Motor On <KF> Motor Off <L1> Relay-1 Pulse <L2> Relay-2 Pulse <N> Noread Counter <O> Noread Counter Reset <T> Trigger Counter <U> Trigger Counter Reset -<V> Match Code/Good Read Counter <W> Match Code/Good Read Counter Reset <X> Mismatch Counter <Y> Mismatch Counter Reset <E> Enable Match Code Type <F> Disable Match Code Type <G> Store Next Label Scanned as Master Label <)XXXX)> Download Master Label Information <)> Request Master Label Information <))> Delete Master Label Information <A> Software Reset (does not save for power-on) <Ad> Software Reset/Restore Default <An> Software Reset/Read NOVRAM <D> Enter Configuration Mode <Z> Software Reset/Save Parameters for Power-on <Zd> Restore/Save Default Configuration for Power-on <Zp> Save Scanner Type, SPS, and Gain for Power-on <#> Display Software Part Number <!> Display Checksum of EPROM <?> Show Scanner Status <?1> Show Software Status (Send Status Byte, Part Number, and ROM Checksum. Display Current NOVRAM Checksum and Display NOVRAM Checksum at Power Up,) <P> Autodiscriminate All Codes <Q> Enable Code 39 Only <R> Enable Codabar Only <S> Enable I 2 of 5 Only MS-710 Scanner User’s Manual