Page 131
Bar Code Symbology
Appendix J, Bar Code Symbology Before choosing a bar code symbol, consider:1 • the type of information to be scanned • the length of the messages to be encoded • how and where labels are to be applied • label printer capabilities
• scan speed • range and beam width • the space available on the object to be identified • host software limitations • the speed of the conveyor
The Standard MS-710 supports the following five bar code symbologies. (Firmware can also be custom ordered to support other symbologies.)
Code 39 An alphanumeric code with unique start/stop code patterns, composed of nine black and white elements per character, three of which are always wide. Considered the de facto standard for non-retail symbology.
Codabar A 16-character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths. It is commonly used in libraries, photo finishing, and air parcel express applications. (A check digit is highly recommended.)
I 2 of 5 Interleaved 2 of 5 is a high-density, continuous numeric symbology used mainly in the distribution industry. I 2 of 5 encodes two digits: one in the bars, and one in the spaces. (A check digit is highly recommended.)
UPC and EAN UPC (Universal Product Code) is a fixed length numeric, continuous symbology used in the supermarket and retail industry. The European Article Numbering (EAN) system is a well-known variation of UPC. Both UPC and EAN can have two or five digit supplemental bar code data following the normal code.
Code 128
1. For further information about symbology, see The Bar Code Book, by Roger C. Palmer, Helmers Publishing, Inc., 1989. MS-710 Scanner User’s Manual
A-27
Appendices
A very high density alphanumeric symbology. Will encode all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge. It is widely used in the non-food distribution industry and shipping containers.
Page 132
Appendix K, Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. With Microscan devices, selection of interface is made by pin assignment and, in the case of the host communications, by software switching between RS-232 and RS-422. Microscan devices use RS-232, RS-422, and RS-485 multidrop.
RS-232 RS-232 defines an interface between two devices such as, for example, the scanner and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (19.7 m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.
RS-422 RS-422, unlike RS-232, measures signals deferentially; that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219 m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line and must have a common ground. It can be used wherever RS-232 is used.
RS-485 RS-485, like RS-422, can transmit up to 4000 feet (1219 m) using differential voltages but unlike RS-422, its transmitters are turned off until a request for data is received from the host. RS-485 is used exclusively in Multidrop protocol.
Appendices
Note: See “Protocol Menu,” on page 2-12 for additional information on standards.
A-28
MS-710 Scanner User’s Manual
Page 133
Multidrop Communications
Appendix L, Multidrop Communications This appendix describes the rules for setting up a concentrator or controller to communicate with a scanner in standard Multidrop protocol. The diagram to the right shows a typical Multidrop network in which 1 to 50 scanners can communicate with a host via an intermediary device, a concentrator or a controller.
Polling Sequence
Host
Concentrator
Data that is transmitted to the host (bar code data, noread messages, counters, etc.) via concentrators is solicited by poll requests from the host.
Polled Protocol Multidrop ONLY RS-485 Interface
Scanner 01 The polling sequence example by poll Scanner 02 address 1E (ASCII hex value for Scanner 02) and a REQ (request). The scanner Scanner 03 responds by first transmitting its own address, 1E, followed by a STX (start of text) character, and then the data. Next it transmits an ETX (end of text) character and an LRC (longitudinal redundancy check) character. If the concentrator (or controller) receives the data from the scanner and is able to validate it with an LRC calculation, it responds with an ACK (acknowledgment). If the scanner in turn receives the ACK, the scanner ends this successful exchange with a RES (reset). Start of Sequence
Concentrator Scanner 02
End of Sequence
RES 1E REQ
ACK 1E STX DATA ETX LRC
RES
Polling Reset
• If the scanner receives a NAK instead of the ACK after transmitting its data string, it will re-attempt to transmit the data string up to three times. If the scanner still does not receive an ACK, it will transmit a RES (reset) and discard the data in its buffers. MS-710 Scanner User’s Manual
A-29
Appendices
• If the scanner has no information, it responds to a poll request by transmitting a RES (reset).
Page 134
• If the scanner transmits data to the concentrator and the concentrator responds with an ACK or NAK, but the scanner doesn’t receive the concentrator’s response, the scanner will timeout and transmit a REQ to the concentrator and request another response. If after three retries (the number of times it transmits a REQ to the concentrator) the scanner receives no response, it ends the transmission with a RES (reset).
Select Sequence Unlike poll requests, select commands always originate from the host and consist of serial configuration or operation commands to devices that are configured in Multidrop. The scanner complies with the command when it is polled during the cycle. Start of Sequence
End of Sequence
Concentrator RES 1F REQ Scanner 02
STX <T>ETX LRC 1F ACK
RES 1F ACK
A RES (reset) is the first command in the select sequence. The 1F hex is the select address associated with Scanner 02 address. It is followed by a REQ (request). The scanner responds with its own select address, 1F hex, and an ACK (acknowledge). The concentrator then transmits an STX (start of text), the data (in this case a <T>), an ETX (end of text), and an LRC character. The scanner replies by transmitting its own address, followed by an ACK, acknowledging receipt of the command. Upon receipt of an ACK, the concentrator concludes the successful exchange with a RES. In the example above, the scanner only acknowledges a trigger counter request from the concentrator. It does not respond to the trigger counter request until a subsequent poll. For example, if the scanner’s trigger count was 12 at the time the trigger counter request was received, on a subsequent poll it would transmit 02T/ 00012. (The 02 at the beginning of the string is the scanner’s address.)
Select Reset
Appendices
If the scanner receives bad data from the concentrator, it transmits a SEL (its select address) and a NAK to the concentrator. The concentrator re-transmits the data up to three times. The concentrator will end the sequence with a RES (reset) if no ACK is received.
A-30
MS-710 Scanner User’s Manual
Page 135
Multidrop Communications Table A-12 Multidrop Address Characters
Multidrop Address 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Poll Character ASCII HEX ^\ ^^ SP " $ & ( * , . 0 2 4 6 8 : < > @ B D F H J L
1C 1E 20 22 24 26 28 2A 2C 2E 30 32 34 36 38 3A 3C 3E 40 42 44 46 48 4A 4C
Select Character ASCII HEX ^] ^! # % ' ) + / 1 3 5 7 9 ; = ? A C E G I K M
1D 1F 21 23 25 27 29 2B 2D 2F 31 33 35 37 39 3B 3D 3F 41 43 45 47 49 4B 4D
Multidrop Address
Poll Character ASCII HEX
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
N P R T V X Z \ ^ ` b d f h j l n p r t v x z | ~
4E 50 52 54 56 58 5A 5C 5E 60 62 64 66 68 6A 6C 6E 70 72 74 76 78 7A 7C 7E
Select Character ASCII HEX O Q S U W Y [ ] _ a c e g i k m o q s u w y { }
∆
4F 51 53 55 57 59 5B 5D 5F 61 63 65 67 69 6B 6D 6F 71 73 75 77 79 7B 7D 7F
Appendices
MS-710 Scanner User’s Manual
A-31
Page 136
Appendix M, Glossary of Terms Autodiscriminate. The ability to decode several different bar code symbologies without changing configuration. AWG. Abbreviation for American Wire Gauge. This is a standard measuring system for wire sizes, listed from 0 (biggest) to 40 (smallest). A 26 AWG is equivalent to 0.0159 in. (0.405 mm) in diameter. Bar Code. Data that has been encoded into an array of parallel bars and spaces of varying widths. Bar Code Density. Number of characters per inch or other unit of measure. Baud Rate. The term used to describe the number of discrete signal events per second. In RS-232 and RS-422/485 systems, baud rate is the same as bits per second (bps). Code 39. An alphanumeric bar code with a character set containing a start/stop character, 10 numbers, 26 letters, 6 symbols, and a space. This code is discrete, variable length, and self-checking. Configuration. The method used to change factory default settings for operational features to match a specific application. Configuration can be done through menu selection or with serial commands. Connector. Physical device (plug or socket) on unit or cable to provide in/out connectivity for various circuits and pins. Counter. Memory space provided to keep track of read cycle events. Daisy Chain. Linkage of primary and successive scanners to allow data to be cascaded up to the host via aux port connections. Decode Rate. The number of good reads per second decoded by the scanner. Depth of Field. The distance between the minimum and maximum range in which a scanner can read bar code labels. End of Read Cycle. The time at which the scanner stops expecting label information to decode. This can be caused by a timeout, a trigger event, or a good read.
Appendices
Focal Length. The distance measured from the scanner to the center of the depth of field, or focal point. Good Read. The event that occurs when a label's data is accurately scanned and decoded. Intercharacter Gap. The extra space between the last element of one character and the first element of the adjacent character of a specific bar code symbol. Label Height. Regardless of orientation, the measurement taken along the length of a label’s individual bars.
A-32
MS-710 Scanner User’s Manual
Page 137
Glossary of Terms Label Length. Regardless of orientation, the measurement taken across the label's bars from one end to the other, including the quiet zone. Label Speed. The rate in inches or centimeters per second at which a label moves through the scan beam. Label Transitions. The transition of bars and spaces on a label, used by the MS-sensor to detect the presence of a label on an object. Ladder Label Orientation. A bar code label in which the bars are parallel to the label’s direction of travel. Match Code. The ability to compare bar code labels being scanned against a master label that is stored in the memory of the scanner. Menu Configuration. The process of changing factory default settings via a sequence of menus displayed on a terminal monitor. Mil. One thousandths of an inch or 0.0254 mm. In bar-coding, a measurement that identifies a bar code label by the width of its narrowest element. Mismatch. An event that occurs when the scanned bar code label does not match the master label that is stored in the memory of the scanner. MS-sensor. An FIS option that analyzes label bar and space transitions and reflected light to determine why a label was not decoded within the triggered read cycle (bad label, no label, or no object), and displays a message to identify the cause. Narrow-bar-width. The width of the narrowest bar of a given label, expressed in thousands of an inch (or mils). Non-volatile RAM (NOVRAM). Random Access Memory that is available on poweron; that is, after power to the unit has been recycled. Noread. A non-read. A condition that occurs when the scanner is set up to decode labels, and no labels are scanned during the read cycle. Number of Scans Calculation. The number of times a bar code label is scanned by the scanner during one pass through the laser beam. Object Detector. A photo electric device used to sense to presence or absence of an object (also referred to as a package detector). Operational Commands. Serial commands from the host to the scanner that control current operating parameters, counters, master label operations, and program management that are not stored in non-volatile RAM.
Pitch. Label (or scanner) rotation around the center a line perpendicular to the label’s bars. Point-to-Point. A protocol consisting of a single communications event, typically used to connect a bar code reader to a terminal or host computer. MS-710 Scanner User’s Manual
A-33
Appendices
Picket Fence Label Orientation. A bar code label in which the bars are perpendicular to the label’s direction of travel.
Page 138
Port. Logical circuit for data entry and exit. (One or more ports may be included within a single connector.) Primary Scanner. First scanner in a daisy chain mode and linked directly to the host and in tandem to succeeding scanners. Protocol. The rules for communication between devices, providing a means to control the orderly flow of information between linked devices. Quiet Zones. Specified “clear” (nonprinted) areas immediately before and after the bar code symbol. The area is usually white (for black and white bar code) and at least 10 times the width of the narrowest bar, as measured in thousands of an inch. The zones can be other than white as long as their densities remains consistent and they have the required contrast relative to the bars. RAM. (Random Access Memory) Memory that is lost after power is recycled to the unit. Read Cycle. A programmed period of time or condition during which the scanner will accept bar code label input. Read Range. The distances in which a label can be reliably read, as measured from the front of the scanner. See “Depth of Field.” Reflectance Threshold. A user-defined setting of reflection (a few digits higher than an empty space reading) that is a point-of-reference for the MS-sensor. A reading lower than the threshold indicates that an object is not present whereas a higher reading indicates the presence of an object. Relay Driver. A TTL signal sent by the scanner. The output is determined by the relay driver selection (by operational command). ROM. (Read Only Memory) Memory that cannot be changed. Scanner. A scanning device that is comprised of a scan head and a decoder integrated in one package. Scan Rate. Number of scans per second that the scanner projects. Scan Width. That portion of the scan line in which a label can be read. Serial Commands. Online data strings (including configuration and operations) from a host or other terminal to the scanner, that are always preceded by a < left angle bracket symbol and followed by a > right angle bracket symbol.
Appendices
Serial Configuration (Host Configuration). Serial command specifically for changing configuration and distinguished from operational command by the fact that they modify the non-volatile for power up configuration. Skew. Label (or scanner) rotation around the center of the skew axis. Specular Reflection. The direct, mirror-like reflection of laser light back to the scanner, causing over-light saturation. For the MS-710 scanner, specular reflection is avoided by skewing or pitching labels slightly.
A-34
MS-710 Scanner User’s Manual
Page 139
Glossary of Terms Successive Scanner. Linked to the primary or preceding scanner in a daisy chain mode via its aux port to relay bar code data to the host. See “Daisy Chain.” Symbology. A set of bar code symbols, such as Code 39 or Code 128, that have special rules to define the widths and positions of bars and spaces to represent specific numeric or alphanumeric information. Tilt. Label (or scanner) rotation around the centerline of the scan beam. Timeout. A user-selected period of time that ends a scanner's read cycle. Wild Card. User-defined character entered into a master label to permit matches with variable characters.
Appendices
MS-710 Scanner User’s Manual
A-35
Page 140
) ® ce ae) r= ® 2. 2. og
A-36 MS-710 Scanner User’s Manual