The text of a manual · part 9 of 11

MS-610 Scanner User's Manual, pages 81 to 90

Pages 81 to 90 of 102

The original document is the PDF (723 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-610 and Microscan MS-615

Page 81

Orientation Note: Raster scanning is almost always done with picket fence labels. Maximum raster height is 0.38 inch at 10 inches.

Angled Picket Fence Orientation The problems associated with picket fence can be minimized by slightly tilting the scan line (figure A-5). This allows a larger portion of the label to be scanned and increases the label placement area by “simulating” the ladder orientation. This of course is impractical with a short bar code height. Angled picket fence is recommended only where the bar code is reasonably tall and the label speed is not too fast in relation to the scan field width, since angling the label will reduce the number of scans on the label. Note: Since raster lines will cross most picket fence labels several times, there is typically no advantage to angled picket fence in connection with raster scanning.

Direction of label travel Scan line Label Label placement area Scan width

Figure A-5 Angled Picket Fence Orientation

Appendices

MS-610 Scanner User’s Manual

A-7

Page 82

Appendices

Appendix D, Defaulting the Scanner Defaulting the scanner resets the configuration parameters to factory default values. Defaulting is necessary if: • You wish to quickly restore default settings to the configuration program after making some temporary changes. 1 • Communications between the scanner and another device are interrupted because of incompatible settings (for example, a terminal is set to communicate at 9600 baud, but the scanner is configured at 38.4K baud). • The scanner has been assigned a polling address and you wish to access the scanner’s menu. Access to the configuration menus of a scanner that is in a polled mode can be forced by sending a <D> command from an auxiliary terminal via the auxiliary RS-232 port. Caution: Be certain that you short the correct pins. Shorting the wrong pins can cause serious damage to the unit.

Procedure: 1. Turn power to the scanner ON. 2. Locate and mark the default pins or wires connecting to default pins. If you have wired your own cable: locate pins 8 and 13 (figure A-6) on the back port of the MS-610 scanner. If using an ADP box: locate pins 11 and 7 (figure A-7) on the 25-pin connector. 3. (Complete this step within three seconds.) Momentarily short the default pins. Listen for a series of quick beeps, then short the default pins again.

Appendices

4. You should hear a longer beep. If not, repeat the process.

Pin 8

Pin 13

Figure A-6 15-pin Socket (on back of scanner) Pin 11

Pin 7

Figure A-7 25-pin Connector, RS-232 (J4) (on back of ADP box)

1. There are no menu options or host commands for resetting the configuration program.

A-8

MS-610 Scanner User’s Manual

Page 83

Troubleshooting

Appendix E, Troubleshooting WARNING Do not look directly into laser aperture. Laser light can be hazardous to your eyes. The MS-610 scanner when used correctly should produce good reads. If not, table A-6 lists some of the more common problems associated with setting up and using the scanner. If you are unable to locate or correct the problem, call your Microscan representative. Table A-6 Troubleshooting Table

Problem

Possible Cause

Solution

Menus do not display when configuration command is sent

Host cable defective or not wired properly Wrong configuration command (or lower case d) entered Scanner configuration settings do not match host's

Check cable connections and wiring. (See “Attach Cabling” on page 1-6.)

Getting only “hieroglyphics” or unintelligible code

Host and scanner baud rates or parity not matched

Check baud rates and parity and change to match the host's settings.

Wrong label type (different label type being scanned than that enabled in firmware) Menus display but no read rate in read rate test (<C>)

Incorrect label range or label too long to be totally covered by scan beam. Poor label quality Excessive ambient light, sunlight, or strobes

Object detector or another scanner interfering with reads

Reset scanner to default and/or match host settings with scanner's.

Check label configuration settings to be certain that they match the label type being scanned. If label type is in doubt, enable Autodiscriminate All Codes (<P> command). Ensure that fixed length and check sums, if enabled, are set correctly. See range data in Step 2, “Verify Read Range and Scan Width” on page 1-3. Reposition label and check the read rate (<C> command). Try a label that is known to be readable. Shield the bar code and/or scan head to verify that excessive light is not the problem. Remedy by remounting, eliminating interference, or shielding. Many object detectors emit pulsed infrared signals that can seriously degrade the read rate if they shine into the scanner or onto the bar code label when it is being read.

MS-610 Scanner User’s Manual

A-9

Appendices

Menus display but no read rate in read rate test (<C>)

Verify that a <D> serial command (with an upper case D) is being entered.

Page 84

Appendices Problem Low read rates during read rate test (<C>)

Possible Cause

Window dirty or obstructed Scanner configured in Continuous Read 1 Output Scanner in polled mode

Check communications protocol.

Proper trigger levels not enabled

Ensure that the trigger pulse and the trigger polarity settings are correct. Ensure that the trigger circuit wiring meets the scanner requirements. (See“Attach Cabling” on page 1-6.) Check detector range and sensitivity. Try a detector that is known to be good.

Poor label, range, placement, etc. Object detector not positioned properly End of Read Cycle not properly defined

Read rate okay but not getting any output (including noreads) in triggered mode

Scanner not triggered when in external mode Scanner not triggered when in serial mode

Label misaligned or reflecting direct laser light

Triggering/timeout out of sync Read rate okay but getting only noread messages in triggered mode

Previous label read, but subsequent label will not read

Appendices

Scanner not entering read cycle in triggered mode (trigger not working)

A-10

Solution See “Menus display...” in previous Problem heading. Do Step 8, “Adjust Other Scanning Parameters” on page 1-11. Ensure read cycle is active during the time the label is in the scan line. Ensure that the proper End of Read Cycle is defined in scanner configuration. Ensure trigger device is operating properly. Do Read Rate Test <C>. If it reads successfully, the problem is triggering. Ensure that correct serial trigger character is entered with start/stop characters (a left angle bracket < (unless redefined) and a right angle bracket >). Ensure the label is not excessively skewed, tilted, or otherwise disoriented. Ensure the bar code is in the scan line when it is supposed to be. Ensure that the bar code is pitched or skewed slightly so as to avoid specular reflection. Review triggering and timing. (See the Operations menu structure on page 2-11.) Remedy by remounting, eliminating interference, or shielding. Many object detectors emit pulsed infrared signals that can seriously degrade the read rate if they shine into the scanner or onto the bar code label when it is being read. Clean or remove obstruction. Scan a label that contains different data than that of the one being read.

Object detector or another scanner interfering with reads

Trigger circuit not correctly wired Object detector inoperative

MS-610 Scanner User’s Manual

Page 85

Optional Equipment

Appendix F, Optional Equipment Mounting Plate Kit Part Number: 98-500002 To mount the scanner with the mounting plate, “pair up” the mounting plate’s four inner screw holes to the scanner’s mounting holes (see figure 31 in chapter 3, “Installation”) and attach plate to scan head. Next, mount entire assembly using the four outer holes on the plate.

3.3" (83.82 mm) 0.25" (6.35 mm)

2.1" (53.34 mm)

Four countersunk holes, for attaching plate to scan head Four 0.156" (3.96 mm) Diameter holes, used to mount plate to any suitable surface

2.8" (71.12 mm) Thickness of Plate = 0.1" (2.54 mm)

1.5" (38.1 mm)

0.3" (7.62 mm)

Figure A-8 MS-520 Bottom Mounting Plate (not full size)

Appendices

MS-610 Scanner User’s Manual

A-11

Page 86

Appendices

Universal Stand The Microscan Universal Stand is available in 4-inch, 6-inch, and 10-inch flex models as well as a 7-1/4" extension kit. 4-inch, knob adjustable handle

98-200008

6-inch, knob adjustable head and foot

98-200007

10-inch flax neck, adjustable head

98-200006

7-1/4-inch extension kit

98-200024

MS-610 Adapter plate

98-200011

4 inch Universal Stand

6 inch Universal Stand

10 inch Flex Neck Universal Stand

Mates to adaptor plate Ball joint

Adjust knob 4" 10.16 cm

.25 " .635 cm

.25 " .635 cm

2" 5.080 cm

.190" DIA. .483 cm DIA. 4 PL 2.5 " 6.350 cm

6" 15.24 cm

10 " 25.40 cm

7-1/4-inch Universal Extension Kit Bottom

7.25" 18.42 cm

1.250 " 3.175 cm

Appendices

1.125 " 2.858 cm

Figure A-9 Universal Stand

A-12

MS-610 Scanner User’s Manual

.50 " DIA.1.270 cm DIA. 3 Pl. .20 " DIA. .508 cm DIA. 3 PL 1.250 " 3.175 cm

C L

1.125 " 2.858 cm

Page 87

Bar Code Symbology

Appendix G, Bar Code Symbology Before choosing a bar code symbol, consider: 1 • the type of information to be scanned (numeric only, alphanumeric) • the length of the messages to be encoded • how and where labels are to be applied • label printer capabilities

• scan speed • beam width • the space available on the object to be identified • host software limitations • range of the scanner • the speed of the conveyor

Microscan standard scanner firmware supports the following five bar code symbologies. (Firmware can also be custom ordered to support other symbologies.) Code 39. An alphanumeric code with unique start/stop code patterns, composed of nine black and white elements per character, three of which are always wide. Considered the de facto standard for non-retail symbology. Codabar. A 16-character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths. It is commonly used in libraries, photo finishing, and air parcel express applications. (A check digit is highly recommended.) I 2 of 5. Interleaved 2 of 5 is a high-density, continuous numeric symbology used mainly in the distribution industry. I 2 of 5 encodes two digits: one in the bars, and one in the spaces. (A check digit is highly recommended.) UPC and EAN. UPC (Universal Product Code) is a fixed length numeric, continuous symbology used in the supermarket and retail industry. The European Article Numbering (EAN) system is a well-known variation of UPC. Both UPC and EAN can have two or five digit supplemental bar code data following the normal code. Code 128. A very high density alphanumeric symbology. Will encode all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge. It is widely used in the nonfood distribution industry and shipping containers.

Appendices

1. For further information about symbology, see The Bar Code Book, by Roger C. Palmer, Helmers Publishing, Inc., 1989. MS-610 Scanner User’s Manual

A-13

Page 88

Appendices

Appendix H, Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. With Microscan devices, selection of interface is made by pin assignment (see table A-3 on page A-3) and, in the case of the host communications, by software switching between RS-232 and RS-422. Microscan devices use RS-232, RS-422, and RS-485 multidrop.

RS-232 RS-232 defines an interface between two devices such as, for example, the scanner and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line (pin 4). Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (19.7 m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.

RS-422 RS-422, unlike RS-232, measures signals differentially that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1575 m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line. It can be used wherever RS-232 is used.

RS-485 RS-485, like RS-422, can transmit up to 4000 feet (1575 m) using differential voltages but unlike RS-422, its transmitters are turned off until a request for data is received from the host. RS-485 is used exclusively in Multidrop protocol.

Appendices

Note: See “Protocol,” on page 2-6 for additional information on standards.

A-14

MS-610 Scanner User’s Manual

Page 89

Multidrop Communications

Appendix I, Multidrop Communications This appendix describes the rules for setting up a concentrator or controller to communicate with a scanner in standard Multidrop protocol, as presented in “ Protocol,” on page 2-6. Figure A-10 shows a typical Multidrop network in which 1 to 50 scanHost ners can communicate with a host via an intermediary device, a concentrator or a controller.

Multidrop Addresses

Concentrator or Controller

Polled Protocol Multidrop ONLY RS-485 Interface (LAN)

• No two scanners in the Multidrop Network can have the same address. • Each scanner in the network Scanner 01 must have an address (from 01 to Scanner 02 50) assigned in its configuration program. Scanner 03 Each address has its own separate poll and select address (from 1C to Figure A-10 Typical Multidrop Network 7F hex as shown in table A-7 on page A-18). For example, during a polling sequence, Scanner 03 expects a 20 hex (“SP” ASCII poll character) from the concentrator. And during a select command, it looks for a select value 21 hex (“!” ASCII select character).

Polling Sequence Data that is transmitted to the host (bar code data, noread messages, counters, etc.) via concentrators is solicited by poll requests from the host.

Concentrator Scanner 02

Start of Sequence

End of Sequence

RES 1E REQ

ACK 1E STX DATA ETX LRC

RES

Appendices

Figure A-11 Polling Sequence

The polling sequence example in figure A-11 begins with a RES (reset) from the concentrator followed by poll address 1E (ASCII hex value for MS-610 Scanner User’s Manual

A-15

Page 90

Appendices Scanner 02) and a REQ (request). The scanner responds by first transmitting its own address, 1E, followed by a STX (start of text) character, and then the data. Next it transmits an ETX (end of text) character and an LRC (longitudinal redundancy check) character. If the concentrator (or controller) receives the data from the scanner and is able to validate it with an LRC calculation, it responds with an ACK (acknowledgment). If the scanner in turn receives the ACK, the scanner ends this successful exchange with a RES (reset).

Polling Reset • If the scanner has no information, it responds to a poll request by transmitting a RES (reset). • If the scanner receives a NAK instead of the ACK after transmitting its data string, it will re-attempt to transmit the data string up to three times. If the scanner still does not receive an ACK, it will transmit a RES (reset) and discard the data in its buffers. • If the scanner transmits data to the concentrator and the concentrator responds with an ACK or NAK, but the scanner doesn’t receive the concentrator’s response, the scanner will timeout and transmit a REQ to the concentrator and request another response. If after three retries (the number of times it transmits a REQ to the concentrator) the scanner receives no response, it ends the transmission with a RES (reset).

Select Sequence Unlike poll requests, select commands always originate from the host and consist of serial configuration or operation commands to devices that are configured in Multidrop. The scanner complies with the command when it is polled during the cycle. Figure A-12 is an example of a select sequence. Start of Sequence

Concentrator Scanner 02

RES 1F REQ

End of Sequence

STX <T>ETX LRC 1F ACK

RES 1F ACK

Appendices

Figure A-12 Select Sequence

A RES (reset) is the first command in the select sequence. The 1F hex is the select address associated with Scanner 02 address (see table A-7 on page A-18). It is followed by a REQ (request). The scanner responds with its own

A-16

MS-610 Scanner User’s Manual