Page 71

Operational Commands

Program Management Commands

<A> Initialize <A> Software Reset. Initializes all serial configuration commands in RAM and RAM resets all counters and operating paramNOVRAM ROM eters. Changes for Baud Rate, Code Length, etc. do not take effect until this command is sent. Note: Software Reset will cause the numeric counters in use to lose their count; record all data that you wish to save prior to sending this command. <D> Enter Configuration Mode. Enters the menu configuration program. See Chapter 2, “Menu Configuration.” <Z> Software Reset/Save ParameInitialize <Z> ters for Power-on. Saves the current RAM configuration to nonvolatile memory for availability on power-on. NOVRAM ROM The values of numeric counters are not saved by this command.

Note: The <Z> Save Configuration command can be executed at least 10,000 times. In normal usage this will exceed the life of the scanner. If frequent changes to the operating parameters are required, it is recommended that the <Z> command be used only when the current configuration has been changed and the changes are to be permanent.

Device Control Commands

MS-610 Scanner User’s Manual

4-3

4–Operations.

<H> Enable Laser Scanning (Laser On). <I> Disable Laser Scanning (Laser Off). This feature is useful during extended periods of time when no bar code labels are being scanned. Disabling laser scanning will not affect any downloaded commands to the scanner. <L> Host Relay Driver Pulse. Allows you to send a pulse to pin 7 at any time regardless of Match Code or Relay Driver status.

Page 72

Chapter 4

Operational Commands

Code Type Commands <P> Autodiscriminate All Codes. Enables the scanner to decode all available bar code types without changing scanner configuration settings. Note: For maximum scanning speed, enable only those bar code symbologies used in the application. <Q> Enable Code 39 Only. Allows only Code 39 labels to be read. <R> Enable Codabar Only. Allows only Codabar labels to be read. <S> Enable I 2 of 5 Only. Allows only Interleaved 2 of 5 labels to be read.

Counter Commands

4–Operations.

The Xs in all counter commands that follow denote a numeric value from 00000 to 65,535. After reaching the maximum numeric limit of 65,535, you will receive an error message and the counter will automatically rollover and start counting again at 00000. To obtain the cumulative total of counts after the rollover has occurred, add 65,536 per each rollover (the scanner does not keep track of the number of rollovers) to the current count. Note: You will lose all counter values if you cycle power to the scanner, send the <A> command, or enter the Menu Configuration Program. Note: If you activate the counter command during a read cycle, the scanner will not output the count until the read cycle ends. <N> Noread Counter. The message N/XXXXX displays the total number of noreads that have occurred since power-on or the last Noread Counter Reset command. <O> Noread Counter Reset. Sets Noread Counter to 00000. <T> Trigger Counter. The message T/XXXXX displays the total number of triggers since power-on or the last Trigger Counter Reset command. <U> Trigger Counter Reset. Sets the trigger counter to 00000. <V> Match Counter (or Good Read Counter). The message V/XXXXX displays the total number of good reads matching the master label since power-on or the last Match Counter Reset command. This counter is always enabled, but will only work as a match count when Match Code option is enabled. If the Match Code option is not enabled, this counter records the number of good reads, or decodes. This count can be requested at any time. <W> Match Counter Reset. Sets the Match Counter to 00000. <X> Mismatch Counter. The message X/XXXXX displays the number of labels successfully read that do not match the master label since power-on or the last Mismatch Counter command. <Y> Mismatch Counter Reset. Sets the Mismatch Counter to zero.

4-4

MS-610 Scanner User’s Manual

Page 73

Operational Commands

Test Commands <C> Enter Read Rate Test. Instructs the scanner to output the read rate 1 and label data (if any). The read rate can vary dramatically due to the angle and location of the Label Read label in relation to the scan beam (or scan Data Rate per line, if using a scan head with a moving Second beam). This test is very useful in aligning and * Example shows output when Postamble is enabled and defined as a positioning the scanning device during instalcarriage return and a line feed. lation. <J> Exit Read Rate Test. Ends the read rate test.

Status Commands <#> Display Software Part Number. Displays software part number. <!> Display Checksum of EPROM. Displays a four-digit hex number (corresponding to a given firmware version) used to verify a scanner’s EPROM.

Master Label Commands

1. If in a triggered mode, the scanner will output the number of good reads based on the number of accepted triggers received. MS-610 Scanner User’s Manual

4-5

4–Operations.

<E> Enable Match Code Option. Identical to match code command on page 2-17. Instructs the scanner to compare bar code labels being scanned with a master label that has been entered in nonvolatile or volatile RAM, and may under certain conditions send out a relay driver signal and update internal counters. If no master label has been entered, every decoded label will be a “mismatch” and will increment the mismatch counter by one. Enable Match Code Option is intended for use when the scanner is in a triggered mode. If the Match Code option is enabled in the Continuous Read mode, the scanner defaults to Continuous Read 1 Output mode, and the label data must change before the scanner will output data again, unless a timeout, if enabled, occurs. (See “Operations Menu” on page 2-11.) <F> Disable Match Code Option. Disables Match Code. <G> Store Next Label Scanned as Master Label. Causes the scanner to read the next bar code label scanned as the master label if Match Code has been enabled. All subsequently decoded labels are compared against the master label information stored in RAM. (See “ Match Code” on page 2-17.) <)XXXX)> Download Master Label Information. Downloads master label information from the host or a terminal. The master label information can be

Page 74

Chapter 4

Operational Commands

4–Operations.

downloaded at any time, and can be saved in nonvolatile memory with a <Z> command. A stored master label will not affect standard operation unless Match Code option is enabled. The Xs denote alphanumeric data, from 1 to 31 characters. <)> Request Master Label Information. Immediately sends the master label information to the host. To prevent conflicts with outputting label data, first send the <I> command (Disable Laser Scanning (Laser Off)). Note: If the master label information has previously been stored in nonvolatile RAM (by a <Z> command), cycling the power will restore that information. <))> Delete Master Label Information. Deletes master label information that has previously been loaded by either <)XXXX)> Download Master Label Information Command or <G> Store Next Label as Master Label command.

4-6

MS-610 Scanner User’s Manual

Page 75

Appendices A

Contents Appendix A, Scanner Specifications ...............................................A-2 Appendix B, ASCII Table .................................................................A-5 Appendix C, Orientation ..................................................................A-6 Appendix D, Defaulting the Scanner ...............................................A-8 Appendix E, Troubleshooting ..........................................................A-9 Appendix F, Optional Equipment ...................................................A-11 Appendix G, Bar Code Symbology ................................................A-13 Appendix H, Interface Standards ..................................................A-14 Appendix I, Multidrop Communications ........................................A-15 Appendix J, Glossary of Terms .....................................................A-19

Appendices

MS-610 Scanner User’s Manual

A-1

Page 76

Appendices

Appendix A, Scanner Specifications Mechanical

Length: 2.92” (74.2 mm) Height: 2.25” (57.2 mm)

Width: 2.25” (57.2 mm) Weight: 9 oz. (257 g)

2.25" (57.2 mm)

Scanning Parameters laser beam exit

Mirror Type: Rotating 10-faceted polygon Scan Rate: 200 scans per second Scan Width Angle: 60° Raster Image: 10 raster scan lines over a 2-degree arc (or 0.24 inch raster at 6-inch distance)

photodetector window 2.25" (57.2 mm) 1.31" (33.3 mm)

Front view

NOTE: Do not block photodetector window.

2.92" (74.2 mm) laser beam exit ±18° light collection angle

2.25" (57.2 mm)

Output Wavelength: 670 nm nominal (visible), 780 nm nominal (infrared) Safety Class: CDRH Class II (visible), CDRH Class I (infrared) Operating Life: 50,000 hours @ 25°C (visible), 400,000 hours @ 25°C (infrared)

2" ( 50.8 mm) ±0.05" Side view

1.32

Scan Range 2 inches (50.8 mm) 4 inches (101.6 mm) 6 inches (152.4 mm) 8 inches (203.2 mm) 10 inches (254 mm)

Raster Height 0.10 inch (2.54 mm) 0.17 inch (4.32 mm) 0.24 inch (6.1 mm) 0.31 inch (7.87 mm) 0.38 inch (9.65 mm)

Communications

Interface: RS-232, RS-422, RS-485 Baud Rates: 300, 600, 1200, 2400, 4800, 9600, 19.2K Parity: Odd, Even, None Stop Bits: 1, 2 Data Bits: 7, 8

Code Types Right angle mirror accessory

2.25" (57.2 mm)

Environment

Power LED (green) Status LED (red) 2.25" (57.2 mm)

Figure A-1 Dimensions

Appendices

Back view

Figure A-1 Mechanical Dimensions Type: Semiconductor Laser Diode Beam Spot: Round or oval

A-2

Protocols

Point-to-Point, Point-to-Point w/RTS/CTS, Point-to-Point w/XON/XOFF, Point-to-Point w/RTS/CTS & XON/XOFF, Polling Mode D, Multidrop, User Defined, User Defined Multidrop

Side view

Light Source

Code 39, Codabar, Interleaved 2 of 5, UPC/EAN, Code 128

Operating Temperature: 32° to 104°F (0° to 40°C) (visible), 32° to 113°F (0° to 45°C) (infrared) Storage Temperature: –58° to 158°F (–50° to 70°C) Humidity: Up to 95% (non-condensing) Ambient Light Immunity: • 450 foot candles (indoor: fluorescent, incandescent, mercury vapor, sodium vapor) • 2000 foot candles (soft outdoors)

I/O Connector

Connector: High-density, 15-pin, D-subminiature socket wired as DTE (RS-232, RS-422, RS-485)

MS-610 Scanner User’s Manual

Page 77

The text of this page cannot be shown here; see it in the PDF.

Page 78

The text of this page cannot be shown here; see it in the PDF.

Page 79

The text of this page cannot be shown here; see it in the PDF.

Page 80

Appendices

Appendix C, Orientation If the bar code label bars are parallel to the direction of travel, as shown in figure A-3, the label is said to be in a ladder orientation; if the bars are perpendicular with the direction of travel, the label is said to be in a picket fence orientation (figure A-4).

Ladder Orientation In general, depending on label size and speed, ladder orientation is preferable because different portions of the label are scanned as the label goes by. In addition, label placement is not as critical. As shown in figure A-3, a label can be successfully read if fully placed (including quiet zones) anywhere within the readable portion of the scan line.

Direction of label travel

Scan line (full width)

Label placement area

Label Figure A-3 Ladder Orientation

Note: Unless your application calls for a stop and go label, it is unlikely that ladder orientation will be used with a raster scanner.

Picket Fence Orientation Unlike ladder, picket fence allows only a small portion of the entire label to be scanned. As a result, labels must be of good quality since even slight label imperfections such as extraneous ink, voids, etc., can cause misreads or non-reads.

Direction of label travel

Label placement area

Scan line Figure A-4 Picket Fence Orientation

Appendices

One advantage of the picket fence over the ladder orientation is in the area of label speed. In ladder mode, the label travel distance is the height of the bar code; in picket fence mode, the label can be read while it travels the full distance of the scan width. Note: Either ladder or picket fence can be rotated without losing its orientation, provided that the label’s direction of travel does not change in relation to the scan line. A-6

MS-610 Scanner User’s Manual