For the Microscan MS-610 and Microscan MS-615
Page 61
Communications Commands
Postamble Format: <Kestatus,postamble character(s) > status: 0 = Disabled 1 = Enabled postamble character(s): Enter one or two postamble characters except a null (00H). Default characters are ^M^J.
Example: To enable Postamble, enter <Ke1>.
Response Timeout Format: <KAtimeout setting> timeout setting: Any number from 0 to 6500 (a zero creates an indefinite wait). Default is 0. Example: To change Response Timeout to 30 ms, enter <KA30>.
LRC Format: <Kcstatus>
3–Serial Config.
status: 0 = Disabled 1 = Enabled Example: To enable LRC, enter <Kc1>.
Intercharacter Delay Format: <KBtime interval> time interval (between characters in milliseconds): Any number from 0 to 255. Default is 0. Example: To change Inter-character Delay to 30 ms, enter <KB30>.
Host Port Format: <Kabaud rate,parity,stop bits,data bits> baud rate: 0 = 600 3 = 4800 1200 4 = 9600 2 = 2400 5 = 19.2K stop bits: 0 = One 1 = Two
6 = 300 parity: 0 = None 1 = Even 2 = Odd data bits: 0 = Seven 1 = Eight
Example: To change Host Port Baud Rate to 2400, enter <Ka2>. MS-610 Scanner User’s Manual
3-7
Page 62
Chapter 3
Serial Configuration
RS-422 Format: <KbRS-422> RS-422: 0 = Disabled
1 = Enabled
Example: To enable RS-422, enter <Kb1>. Note: Whenever RS-422 is disabled, RS-232 is enabled in the background. However, an exception occurs whenever Multidrop has been selected. In this case the functioning protocol will be RS-485 regardless of the displayed status of RS-422 in the menus.
Operations Commands Triggering Mode Format: <Kgtriggering mode>
3–Serial Config.
triggering mode: 0 = Continuous Read 1 = Continuous Read 1 Output 2 = External Level
3 = External Edge 4 = Serial Data 5 = Serial Data & Edge
Example: To select External Edge, enter <Kg3>.
End of Read Cycle Format: <Khend of read cycle mode,timeout > end of read cycle mode: 0 = Timeout 1 = New Trigger 2 = Timeout & New Trigger timeout (in 10 millisecond increments): Any number between 0 and 65535. Default is 100 (one second).
Example: To select Timeout and change the timeout value to 6 seconds, enter <Kh0,600>. 1
Serial Trigger Character
Format: <Kiserial trigger character > serial trigger character: Any available ASCII character (see “ASCII Table with Control Characters” on page A-5). Default is ^]. 1. Avoid selecting a serial trigger character that is also an operational command. For example, an uppercase C cannot be used as a serial trigger character because it is the operational command for Enter Read Rate Test. However, a lowercase c could be used without initiating the read rate test.
3-8
MS-610 Scanner User’s Manual
Page 63
Operations Commands Example: To define the Serial Trigger Character as a lowercase c, enter <Kic>.
External Trigger Level Format: <Kjexternal trigger level> external trigger level (initiates a read cycle): 0 = Negative 1 = Positive Example: To change External Trigger Level to Negative, enter <Kj0>.
Noread Message Format: <Kkstatus,message> status: 0 = Disabled 1 = Enabled message: Any ASCII string up to 7 digits. Default is NOREAD.
Example: To enable Noread Message and send the message “FAIL,” enter <Kk1,FAIL>.
3–Serial Config.
Bar Code Output Format: <Klstatus,when to output> status: 0 = Disabled 1 = Enabled when to output: 0 = As Soon As Possible 1 = End of Read Cycle
Example: To set When to Output to End of Read Cycle, enter <Kl3,1>.
Good Decode Reads Format: <Kmnumber of reads> number of reads (before a good decode): Any number from 1 to 31. Default is 1. Example: To change Good Decode Reads to 3, enter <Km3>.
Match Code Format: <Knstatus> status: 0 = Disabled 1 = Enabled Example: To enable Match Code, enter <Kn1>. MS-610 Scanner User’s Manual
3-9
Page 64
Chapter 3
Serial Configuration
Code Types Commands Narrow Margins Format: <Kostatus> status: 0 = Disabled 1 = Enabled Example: To enable Narrow Margins, enter <Ko1>.
Code 39 Format: <Kpstatus,check digit status,check digit output status,large intercharacter gap,fixed code length status,code length> check digit output status: 0 = Disabled 1 = Enabled large intercharacter gap : fixed code length status: code length: Any number from 1 to 0 = Disabled 0 = Disabled 1 = Enabled 1 = Enabled 31. Default is 10.
3–Serial Config.
status: 0 = Disabled 1 = Enabled check digit status: 0 = Disabled 1 = Enabled
Example: To set Fixed Code Length to 30, enter <Kp,,,,1,30> or <Kp1,0,0,0,1,30>.
Codabar Format: <Kqstatus,start & stop match status,start & stop output status,large intercharacter gap,fixed code length status,code length > status: 0 = Disabled 1 = Enabled start & stop match status: start & stop output status: 0 = Disabled 1 = Enabled 0 = Disabled 1 = Enabled large inter-character gap : fixed code length status: code length: Any number from 1 0 = Disabled 0 = Disabled 1 = Enabled 1 = Enabled to 31. Default is 10. Example: To set Fixed Code Length to 9, enter <Kq,,,,1,9> or <Kq1,1,1,0,1,9>.
3-10
MS-610 Scanner User’s Manual
Page 65
Code Types Commands
I 2 of 5 Format: <Krstatus,check digit status,check digit output status,code length #1,code length #2> status: 0 = Disabled 1 = Enabled check digit status: 0 = Disabled 1 = Enabled code length #1: Zero or any even number from 2 to 30. Default is 10.
code length #2: Zero or any even number from 2 to 30. Default is 6.
check digit output status: 0 = Disabled 1 = Enabled
Example: To set Fixed Code Length #1 to 8 and Fixed Code Length #2 to 4, enter <Kr,,,8,4> or <Kr1,0,0,8,4>.
UPC/EAN UPC status: 0 = Disabled 1 = Enabled separator status: 0 = Disabled 1 = Enabled
EAN status: 0 = Disabled 1 = Enabled (UPC must also be enabled) separator character: Any ASCII character (except NUL). Default is a comma (,).
supplementals status: 0 = Disabled 1 = Enabled 2 = Required
Example: To change Supplementals to Required, and change Separator Character to a dash (–), enter <Ks1,1,2,1,–> or <Ks,,2,1,–>.
Code 128 Format: <Ktstatus,fixed code length status,code length> status: 0 = Disabled 1 = Enabled fixed code length status: code length: Any number from 1 to 31. 0 = Disabled Default is 10. 1 = Enabled
Example: To enable Code 128, enable Fixed Code Length, and set Code Length to 9, enter <Kt1,1,9>.
MS-610 Scanner User’s Manual
3-11
3–Serial Config.
Format: <KsUPC status,EAN status,supplementals status,separator status,separator character >/
Page 66
Page 67
User Outputs Commands
Relay Driver Format: <Kvmode> mode: 0 = Good Read 1 = Noread 2 = Match
3 = Mismatch 4 = Mismatch or Noread
Example: To change Relay Driver to NOREAD, enter <Kv1>.
Relay Polarity Format: <Kwpolarity> polarity: 0 = Negative 1 = Positive Example: To change Relay Polarity to Negative, enter <Kw0>.
3–Serial Config.
Relay Pulse Width Format: <Kxpulse width> pulse width (in 10 millisecond increments): Any number from 0 to 255. Default is 5 (50 ms). Example: To set Relay Pulse Width to 600 ms, enter <Kx60>.
Command Start Character Format: r<KEcommand start character > ASCII character: Any ASCII character. Default is <. Example: To change Command Start Character to a colon (:), enter <KE:>. Note: Subsequent commands must start with a colon (:). For example, enter :D> to access the Menu Configuration Program, or :KE<> to change back to the default character.
MS-610 Scanner User’s Manual
3-13
Page 68
Chapter 3 Serial Configuration
2 = c je} O © ‘c o ° o
3-14 MS-610 Scanner User’s Manual
Page 69
Chapter
4
Operational Commands Chapter Contents Summary of Operational Commands .......................................... 4-2 Program Management Commands .............................................. 4-3 Device Control Commands .......................................................... 4-3 Code Type Commands ................................................................ 4-4 Counter Commands ..................................................................... 4-4 Test Commands .......................................................................... 4-5 Status Commands ....................................................................... 4-5 Master Label Commands ............................................................. 4-5
1. Command start character by default is a left angle bracket, <. It may be redefined by menu or serial command. However, the end character, a right angle bracket, >, cannot be changed. MS-610 Scanner User’s Manual
4-1
4–Operations.
This chapter describes all of the serial operational commands and their functions. See “Summary of Operational Commands ,” on page 4-2 for quick reference. On-line serial operational commands are sent from the host to the scanner to carry out routine operations “on the fly” as distinguished from serial configuration commands that are generally used in initial setup. Operational commands are preceded by a < left angle bracket symbol and followed by a > right angle bracket symbol. 1
Page 70
Chapter 4
Operational Commands
Summary of Operational Commands Table 4-1 Summary of Operational Commands
Command Type
Command
Program Management
<A>
Software Reset (does not save for power-on)
<D>
Enter Configuration Mode
<Z>
Software Reset/Save Parameters for Power-on
<H>
Enable Laser Scanning (Laser On)
<I>
Disable Laser Scanning (Laser Off)
Device Control
Code Types
Counter
4–Operations.
Test Status
Master Label
Result
<L>
Host Relay Driver
<P>
Autodiscriminate All Codes
<Q>
Enable Code 39 Only*
<R>
Enable Codabar Only*
<S>
Enable I 2 Of 5 Only*
<N>
Noread Counter
<O>
Noread Counter Reset
<T>
Trigger Counter
<U>
Trigger Counter Reset
<V>
Match Counter
<W>
Match Counter Reset
<X>
Mismatch Counter
<Y>
Mismatch Counter Reset
<C>
Enter Read Rate Test
<J>
Exit Read Rate Test
<#>
Display Software Part Number
<!>
Display Checksum of EPROM
<E>
Enable Match Code Option*
<F>
Disable Match Code Optiona
<G>
Store Next Label Scanned as Master Label
<)XXXX)>
Download Master Label Information
<)>
Request Master Label Information
<))>
Delete Master Label Information a. Can also be set in the configuration menu or with a serial configuration command.
4-2
MS-610 Scanner User’s Manual