Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 11

MS-610 Scanner User's Manual, pages 41 to 50

Pages 41 to 50 of 102

The original document is the PDF (723 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-610 and Microscan MS-615

Page 41

Operations Menu

Good Decode Reads

Match Code Default: Disabled Options: Disabled, Enabled Note: A triggered mode (page 2-11 to page 2-12) must be enabled for Match Code to take effect. Note: If both Match Code and Continuous Read are enabled the scanner defaults to Continuous Read 1 Output mode, and the label data must change before the scanner will output data again, unless a timeout, if enabled, occurs. Allows you to enter a master label into the scanner's memory to be compared with subsequently scanned labels. With Match Code enabled, a master label can be entered in three ways: 1. With New Master Pin enabled (see page 2-27), toggling pin 5 to ground (pin 12) enables the next good read to be the master label. 1. Sending serial command <G> enables the next good read to be the master label. 1. Sending serial command <)XXXX)> downloads data as master label.

MS-610 Scanner User’s Manual

2-17

2–Menu Config.

Default: 1 Options: 1 to 31 Allows you to select the number of good reads (from 1 to 31) required per label before a good decode output. Note: Be sure to set the value within the determined scan rate for the scanning setup so that the scanner is capable of scanning a label the required number of times.

Page 42

Chapter 2

Menu Configuration Figure 2-6 on page 2-18 shows the sequence of operation (and reference) for setting up and entering master labels. Enable Match Code:

* See the option/outputs available in the relay driver you have selected (page 2-26).

– 1. by menu selection

(page 2-17),

– 2. by operational command <E>, or

– 3. by serial configuration

2–Menu Config.

command <Kn1>

Enable New Master Pin: – 1. by menu selection, or

– 2. by serial configuration command <Kz1>

Toggle internal pin 5 to GND (pin 12) to enter next label scanned as the master label.

Enter the next label scanned as the master label: – 1. by operational command <G>

Download a new master label directly into memory: – 1. by operational command

<)XXXX)>

Read in the master label.

Compare the master label with subsequent labels*

Figure 2-6 Match Code Logic Diagram

If Match Code is enabled, Relay Driver (page 2-28) must be set to an option other than Good Read. If Relay Driver is set to Good Read, there will be no output to the host or a relay pulse.

2-18

MS-610 Scanner User’s Manual

Page 43

Code Types Menu

Code Types Menu

Narrow Margins Default: Disabled Options: Disabled, Enabled Allows the scanner to read bar codes with quiet zones less than 10 times the narrow-bar-width. Quiet zone is a term used to describe the minimum space at the leading and trailing ends of a label. Each quiet zone can be as small as five times the narrow bar element when Narrow Margins is enabled.

Code 39 Status Default: Enabled Options: Enabled, Disabled

Check Digit Default: Disabled Options: Disabled, Enabled Code 39 is self-checking and does not normally require a check digit. However, for additional data integrity, a Modulus 43 check digit can be added to the bar code message. With Check Digit and an External or Serial trigger option enabled (see “Triggering Mode” on page 2-11), an invalid check digit calculation will cause a noread message to be transmitted at the end of the read cycle.

MS-610 Scanner User’s Manual

2-19

2–Menu Config.

The Code Types menu allows you to choose among five bar code types and define their parameters. To help visualize the menu’s organization and to locate the page number where each topic is described, see figure 2-7, “ Code Types Menu Structure ,” on page 2-20. Note: Options listed in the command line do not always appear in the same order as those posted in the first column of the menu. Options can be defined for any bar code type whether or not the bar code itself is enabled at the time.

Page 44

Chapter 2

Menu Configuration

Code Types – Bold text represents default settings.

Narrow Margins – Disabled – Enabled

Code 39

2–Menu Config.

Status – Enabled – Disabled

Check Digit – Disabled – Enabled

Check Digit Output

Large Interchar Gap

– Disabled

– Disabled

Start & Stop Output

Large Interchar Gap

– Enabled

– Enabled

Fixed Code Length

Code Length – 10

– User

– Disabled

Definable (1 to 31)

– Enabled

Codabar Status – Disabled – Enabled

Start & Stop Match – Enabled

– Enabled

Check Digit

Check Digit Output

– Disabled

– Disabled – Enabled

– Disabled

Fixed Code Length

Code Length

– Disabled – Enabled

– 10

– User

Definable (1 to 31)

I 2 of 5 Status – Disabled – Enabled

– Disabled – Enabled

– Disabled – Enabled

Code Length #1 – 10

– User Definable

(even, 0 to 30)

Code Length #2 – 6

– User Definable

(even, 0 to 30)

UPC Status – Disabled – Enabled

EAN – Disabled – Enabled

Supplementals – Disabled – Enabled

– Required

Separator – Disabled – Enabled

Separator (character) – , (comma)

– User Definable

(ASCII char.)

Code 128 Status – Disabled – Enabled

Fixed Code Length – Disabled – Enabled

Code Length – 10

– User Definable

(1 to 31)

Figure 2-7 Code Types Menu Structure

2-20

MS-610 Scanner User’s Manual

Page 45

Code Types Menu

Check Digit Output Default: Disabled Options: Disabled, Enabled When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit.

Large Intercharacter Gap

Fixed Code Length Default: Disabled Options: Disabled, Enabled Used to increase data integrity by ensuring that only one label length will be accepted.

Code Length Default: 10 Options: 1 to 31 NOTE: Fixed Code Length (page 2-21) must be enabled for Code Length to take effect. Allows you to specify the exact number of characters that the scanner will recognize (this does not include start and stop). The scanner will ignore any code not having the specified length.

MS-610 Scanner User’s Manual

2-21

2–Menu Config.

Default: Disabled Options:Disabled, Enabled Allows the scanner to read labels with gaps between bar code characters exceeding three times the narrow element width.

Page 46

Chapter 2

Menu Configuration

Codabar Status Default: Disabled Options: Disabled, Enabled

Start & Stop Match 2–Menu Config.

Default: Enabled Options: Enabled, Disabled Requires the Codabar start and stop characters (a, b, c, or d) to match before a valid read can occur.

Start & Stop Output Default: Enabled Options: Enabled, Disabled Allows the start and stop characters to be transmitted with bar code data.

Large Intercharacter Gap Default: Disabled Options:Disabled, Enabled Allows the scanner to read labels with gaps between bar code characters exceeding three times the narrow element width.

Fixed Code Length Default: Disabled Options: Disabled, Enabled Used to increase data integrity by ensuring that only label length will be accepted.

Code Length Default: 10 Options: 1 to 31 Note: Fixed Code Length (page 2-22) must be enabled for Code Length to take effect. Allows you to specify the exact number of characters that the scanner will recognize. The scanner will ignore any code not having the specified length.

2-22

MS-610 Scanner User’s Manual

Page 47

Code Types Menu

Interleaved 2 of 5 Status

Check Digit Default: Disabled Options: Disabled, Enabled I 2 of 5 uses a Modulus 10 check digit.

Check Digit Output Default: Disabled Options: Disabled, Enabled When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit.

Code Length #1 Default: 10 Options: 0 to 30, even. If you enter an odd number the scanner will use the next lower number. With I 2 of 5, two code lengths can be defined. When using only one label length in an application, we recommend setting Code Length #2 to 0 to ensure data integrity. If a check digit is used, it must be included in the code length count.

Code Length #2 Default: 6 Options: 0 to 30, even. If you enter an odd number the scanner will use the next lower number. If using a second label, you may also specify a zero or any even code length from 2 to 30. If not using a second label, set Code Length #2 to 0 to ensure data integrity.

MS-610 Scanner User’s Manual

2-23

2–Menu Config.

Default: Disabled Options: Disabled, Enabled Because I 2 of 5 is a continuous code, it is prone to substitution errors. Hence, a code length must be defined and a bar code label containing an even number of digits must be used. It is also recommended that a Modulus 10 check digit be used to ensure the best possible data integrity.

Page 48

Chapter 2

Menu Configuration

UPC Status Default: Disabled Options: Disabled, Enabled When enabled, the scanner will read UPC version A and UPC version E only.

EAN 2–Menu Config.

Default: Disabled Options: Disabled, Enabled Note: UPC must be enabled for EAN to take effect. When EAN is enabled, the scanner will read UPC version A, UPC version E, EAN 13, and EAN 8. It will also append a leading zero to UPC version A label information and transmit 13 digits. If you do not want to transmit 13 digits when reading UPC version A labels, disable EAN.

Supplementals Default: Disabled Options: Disabled, Enabled, Required Note: Supplementals is set to Enabled, Triggering Mode (page 2-11) must not be set to Continuous Read 1 Output. Allows the scanner to read supplemental bar code data that has been appended to the standard UPC or EAN codes. When set to Required, the scanner treats the supplemental data and the bar code label as a single label. Also, supplemental data must be found or a noread will result. When set to Enabled, the scanner treats the supplemental data and the bar code label as separate labels.

Separator Default: Disabled Options: Disabled, Enabled Allows you to insert a character between the standard UPC or EAN code and the supplemental code.

Separator (character) Default: , (comma) Options: Any ASCII character. Allows you to change the separator character from a comma to a new value. 2-24

MS-610 Scanner User’s Manual

Page 49

Code Types Menu

Code 128 Status Default: Disabled Options: Disabled, Enabled

Fixed Code Length

Code Length Default: 10 Options: 1 to 31 Note: Fixed Code Length must be enabled for Code Length to take effect. Allows you to specify the exact number of characters that the scanner will recognize. The scanner will ignore any code not having the specified length.

MS-610 Scanner User’s Manual

2-25

2–Menu Config.

Default: Disabled Options: Disabled, Enabled Allows you to increase data integrity by ensuring that only one label length will be accepted.

Page 50

Chapter 2

Menu Configuration

User Outputs Menu The User Outputs menu allows you to control the external (video or audio) outputs that identify scanning conditions. To help visualize the menu’s organization and to locate the page number where each topic is described, see figure 2-8 on page 2-26.

Beeper Status 2–Menu Config.

Default: On Good Options: On Good, On Noread, Disabled A beep is emitted either after each good read of a bar code label or after each noread. Note: The beep period will be short for triggered modes where a new trigger occurs immediately or the output is delayed to the end of the read cycle on edge and serial triggers. User Outputs (page 2-26)

Beeper Status

– Bold text represents default settings.

(page 2-27)

Beeper Volume

– On Good

– Level 4

– Disabled

– Level 1

– On Noread

– Level 5 – Level 2

(page 2-27)

Beeper Speed – Fast

– Slow

(page 2-27)

(page 2-27)

(page 2-27)

– Enabled

– Disabled

– Disabled

Full Screens

New Master Pin

– Disabled

Laser On/Off

– Enabled

– Enabled

– Level 3

(page 2-28)

Clock Speed

– Slow – Fast

(page 2-16)

Relay Driver – Good Read – Noread – Match

– Mismatch

(page 2-29)

Relay Polarity

– Positive

– Negative

– Mismatch or

(page 2-29)

– User Definable

(0 to 255)

Noread

* Divide the number entered on the command line by 100 for time in seconds.

Figure 2-8 User Outputs Menu Structure

2-26

MS-610 Scanner User’s Manual

(page 2-29)

Relay Pulse Width Command Start (in 10 ms incs) * Character – 50 ms – <

– User

Definable (ASCII char.)