Verify Read Range and Scan Width
Table 1-1 shows readable ranges and maximum scan widths for specific bar code density (narrow-bar-width) types. Use this table as a reference to verify that the planned range for your label falls within one of the listed ranges. Scan width is that portion of the scan line in which a label can be read. For ladder oriented labels, scan width must only be wide enough to fully cover the label length, including quiet zones. With picket fence oriented labels, scan width is a factor in determining the time in which the label can be read (see Calculate Number of Scans ” on page 1-4). Table 1-1 Read Ranges and Scan Widths
Laser Type
Range UHD
Visible Standard
UHD
Infrared Standard
Narrowbar-width
Read Rangea
Maximum Scan Width
.0047” .0075” .0075” .010” .015” .020” .030” .040” .050” .0047” .0075” .0075” .010” .015” .020” .030” .040” .050”
1.75–3” (45–76 mm) 1–4” (25–102 mm) 2–5” (51–127 mm) 1.5–6” (38–152 mm) 1–7” (25–178 mm) 1–9” (25–229 mm) 4–10” (102–254 mm) 4–10” (102–254 mm) 5–10” (127–254 mm) 1.75–3” (45–76 mm) 1.25–3” (32–76 mm) 2–4.5” (51–114 mm) 1.5–5” (38–127 mm) 1–6” (25–152 mm) 1–7” (25–178 mm) 4–9” (102–229 mm) 4–9” (102–229 mm) 5–9” (127–229 mm)
3” (76 mm) 4” (102 mm) 4.75” (121 mm) 6” (152 mm) 7.5” (191 mm) 9.25” (235 mm) 9.5” (241 mm) 9.5” (241 mm) 9.75” (248 mm) 3” (76 mm) 3.5” (89 mm) 3.5” (89 mm) 4.75” (1.21 mm) 6” (152 mm) 7” (178 mm) 8.5” (216 mm) 8.5” (216 mm) 8.5” (216 mm)
a. Read range is the distance of the label from the scanner (measured from the front of the scanner bezel) in which the label can be reliably read. The distance between the minimum and maximum ranges is the depth of field.
For information on label orientation, see Appendix C, “ Orientation,” on page A-6.
MS-610 Scanner User’s Manual
1-3
1–Setup and Inst.
2 Verify Read Range and Scan Width
Page 12
Page 13
Calculate Number of Scans 1–Setup and Inst.
Angled Picket Fence Calculation The number of complete scans for angled picket fence is calculated the same as that for picket fence, with the exception that the scan width is shortened in proportion to scan tilt.
Direction of label travel
Scan Line
Figure 1-5 Angled Picket Fence Orientation
• Scan Rate (SR) is the number of scans per second that a given scanner is capable of emitting. • Scan Width (SW) (picket fence formula only) is the width across the scan beam, at a given distance from the scanner, in which a label can be read. • Label Speed (LS) is the distance per second that a label moves as it travels through the scan lines. • Label Length (LL) (picket fence Label length Label length formula only) is the length of the Label longest printed label to be read Label height height plus the length of the quiet zones (figure 1-6). • Label Height (LH) (ladder formula Quiet zones Quiet zones only) is a measurement of the height of individual bars (figure 1-6). Figure 1-6 Label Dimensions
Note: While the formulas given here solve for the predicted number of scans, you may also assign a value for number of scans (5 or more) and to solve for other parameters that might be changed, such as scan rate (motor speed), label speed, etc.
MS-610 Scanner User’s Manual
1-5
Page 14
Chapter 1
Setup and Installation
1–Setup and Inst.
4 Attach Cabling
5
The MS-610 scanner uses a high-density, 15-pin, D-subminiature socket connector (figure 1-7) for all input and output.
4
3
8
2
1 7
10
15
Caution: Switching power supplies for Microscan equipment with switching noise of 20 mV p-p or greater with ±12 VDC are not recommended.t
14
9
12 13
11
6
Figure 1-7 High Density 15-pin D-Sub Miniature Socket
Table 1-3 Scanner/MS-610 ADP (adapter) Pinouts
Table 1-2 Pin Assignments
Connectors Pin #
Function
15-pin MS610
25-pin Host
Power Supply 3
3
1
5
1
+5 VDC (input)
1
9
2
RS-232 (transmit)
2
2
Object RS-422/ Detector 485
3
RS-232 (receive)
3
3
4
RS-232 (signal gnd)
4
7
5
5, 14
5 4
5
CTS,a RS-422/RS-485 (– transmit), or New Master Pin
6
RTS or RS-422/RS-485 (+ transmit)b
6
4, 19
7
Relay Driver (5V, 20 mA capability) (output)
7
8
8
Reset (to default configuration) (input)
8
11
9
Trigger (input) (3 to 24 VDC)
9
10
10
Signal Ground
10
11
+12 VDC (input)
11
12
RS-422/RS-485 (+ receive)
12
13
13
GND (chassis)
13
1
14
RS-422/RS-485 (– receive)
14
16
15
–12 VDC (input)
15
1 5
4 2
2 3 4 a. CTS is used with the RS-232 option. See “FIS Options” on page A-4. b. RTS is used with the RS-232 option. See “FIS Options” on page A-4.
1-6
MS-610 Scanner User’s Manual
1, 6
Page 15
Attach Cabling
MS-610 Scanner User’s Manual
1–Setup and Inst.
Under ideal conditions, maximum cable lengths can meet the distances shown in table 1-4. However, since cable lengths and sizes are dictated by local conditions such as wire size, wire shape (flat or round), shielding, grounding, extraneous signal noise, etc., maximum cable distances will be variable.
Table 1-4 Cable Distances
Maximum Distance
Interface
50 feet
RS-232
4000 feet
RS-485 Multidrop
4000 feet
RS-422
1-7
Page 16
Chapter 1
Setup and Installation
1–Setup and Inst.
5 Configure Scanner
Settings for Communications, Operations, Code Types, and User Outputs are stored in non-volatile memory and can be configured from a host or auxiliary terminal by menu (Chapter 2, “ Menu Configuration ”) or serial command (Chapter 3, “Serial Configuration ”). For explanations of configuration settings, see Chapter 2, “ Menu Configuration” To establish communication you will need to match the host’s or auxiliary terminal’s communication settings with your scanner’s settings (see Communications Menu ” on page 2-5). Also make certain that the code type enabled in the scanner matches that of the label being used (see Code Types Menu” on page 2-19). Hint: Enabling autodiscrimination in the menus (or with the <P> command) will allow your scanner to read all of the listed code types.
Communicating with an ASCII Terminal The MS-610 scanner communicates in full duplex, terminal mode with no handshake. It also recognizes carriage returns and line feeds. The host or ASCII terminal with must match the following default settings before any communication can take place: 9600 Baud Rate, Seven Data Bits, Even Parity, and One Stop Bit. A PC or Macintosh computer can be used as an ASCII terminal if connected as shown in table 1-3 and running a communications program set to the above defaults. See your computer manual for communication’s port pinouts.
1-8
MS-610 Scanner User’s Manual
Page 17
Position Scanner and Label
Before testing the read rate, you will need to position the scanner and label in a manner that matches as nearly as possible the actual conditions of your application. a. Position the scanner and label, taking care to avoid excessive tilt, skew, or pitch. 1 Note: The photo diode, located behind the large window on the scanner, cannot be blocked because it receives the return signal from each scan. See mechanical specifications on page A-2.
b. Pitch label (or scanner) slightly up or down as shown in figure 1-8 to avoid specular reflection, the return of direct, non-diffused light. 2 Another way to avoid specular reflection is to skew the scanner slightly relative to the label.
Bar code label
Skew axis Tilt axis
MS-610 Scanner Pitch axis
Note: If this label were moving from left to right (or vice versa), the orientation of the label, relative to the scan beam, would be “picket fence;” if the label were moving from top to bottom (or vice versa), the orientation of the label, relative to the scan beam, would be “ladder.”
Note: For test purposes the label shown here is pitched. In final installation, it is typically the fixed-mount scanner rather than the moving label that is pitched. Figure 1-8 Tilt, Skew, and Pitch Axes
For more information, see Appendix C, “ Orientation,” on page A-6.
1. Maximum tilt is determined by label characteristics and number of scans required. Maximum skew is ±40°; maximum pitch is ±50°. 2. The specular reflection zone is a narrow zone straight out from the scanner in which direct reflected light from a label can distort the scanner’s ability to distinguish bars from spaces.
MS-610 Scanner User’s Manual
1-9
1–Setup and Inst.
6 Position Scanner and Label
Page 18
Chapter 1
Setup and Installation
1–Setup and Inst.
7 Do Read Rate Test To begin the read rate test:
a. Position the label in front of a functioning scanner; enter the <C> command from the host terminal to launch the read rate test (see Status Commands” on page 4-5). b. Observe read rate. c. Check depth-of-field (minimum/maximum range) by moving the label closer and further relative to the scanner and noting the points where the read rates fall below a level acceptable to your application. Ideally, the label used in your application should pass through or near the center of the depth-of-field.
Read Rate per Second
Label Data * Example shows output when Post- d. Repeat steps a through c for other labels used in your application and end the read rate test with the <J> command. If the read rate is acceptable, go to Step 9, “ Install Scanner,” on page 1-13. If the read rate is unacceptable, go to Step 8, “ Adjust Other Scanning Parameters,” on page 1-11. Important: If, after making adjustments, you have changed the read range or another parameter used in the number of scans formula, you should recalculate the number of scans (Step 3, “Calculate Number of Scans,” on page 1-4). Note: Variations between labels are common. For this reason, the greater number of sample labels you test, the more likely you are to achieve optimum read rates.
1-10
MS-610 Scanner User’s Manual
Page 19
Adjust Other Scanning Parameters
This section lists various adjustments that may improve read rates. After changing any of the parameters described in this section, a. If applicable, recalculate the number of scans (Step 3, “Calculate Number of Scans,” on page 1-4). b. Repeat Step 7, “Do Read Rate Test,” on page 1-10. c. Compare the new read rate results with those obtained before changes were made.
Range Adjusting the label’s range, if possible, is one of the quickest and most effective ways to improve read rates. However, in some applications you may need to select a less than optimum range, or one that is beyond the fringes of the ranges listed in table 1-1 on page 1-3. After making changes, repeat Step 3, “ Calculate Number of Scans ,” on page 1-4 and Step 7, “ Do Read Rate Test,” on page 1-10.
Scan Width Increasing scan width will increase the number of scans in a picket fence oriented application. Scan width is linked with scan range (as shown in table 1-1 on page 1-3) and changing one will usually require a change in the other. After making changes, repeat Step 3, “ Calculate Number of Scans ,” on page 1-4 and Step 7, “ Do Read Rate Test,” on page 1-10.
Label Speed Applies to both picket fence and ladder oriented labels. If your application allows it, label speed (the time in seconds that a label is fully within the scan width of the scanner) is an effective way to alter the number of scans. After making changes, repeat Step 3, “ Calculate Number of Scans ,” on page 1-4 and Step 7, “ Do Read Rate Test,” on page 1-10.
Label Dimensions, Label Density, and Label Ratio Not usually an option in most applications, but changes to label parameters can affect number-of-scan calculations and possibly read rates. If your application allows it, shortening the length of a picket fence label means the label will be in the scan range longer and hence receive a greater number of scans. Increasing the height of a ladder label means it
MS-610 Scanner User’s Manual
1-11
1–Setup and Inst.
8 Adjust Other Scanning Parameters
Page 20
1–Setup and Inst.
Chapter 1
Setup and Installation will receive more scans. Changing label density and/or bar code ratio is another way ranges, read rates, etc. can be altered. After making changes, repeat Step 3, “ Calculate Number of Scans ,” on page 1-4 and Step 7, “ Do Read Rate Test,” on page 1-10.
1-12
MS-610 Scanner User’s Manual