The text of a manual · part 1 of 11
MS-610 Scanner User's Manual, pages 1 to 10
Pages 1 to 10 of 102
The original document is the PDF (723 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-610 and Microscan MS-615
Page 1
MICROSCAN.
MS-610 Scanner User's Manual
P/N 83-000600 Rev C
Page 2
Information and specifications in this manual are subject to change without notice. Copyright © 1998 by Microscan Systems, Inc., 1201 S.W. 7th Street, Renton, Washington, U.S.A. 98055 (425) 226-5700 FAX: (425) 226-8682 All rights reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Microscan manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Microscan. Throughout this manual, trademarked names might be used. Rather than put a trademark (™) symbol in every occurrence of a trademarked name, we state herein that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement. Warranty Information Microscan Systems, Inc. warrants products manufactured by it to be free from defects in material or workmanship under normal use and service for a period of one year from date of shipment. This warranty is specifically limited to the replacement or repair of any such warrantable defects, without charge, when the complete product is returned to Microscan Systems, Inc., freight prepaid, at the address shown above. Contact the factory at the address above for a Return Material Authorization (RMA) number before returning the product. Microscan Systems, Inc. shall be the sole judge of the warrantability of alleged product defects. Products that are returned for warranty examination and that are found to be non-warrantable are chargeable and are returned freight collect. Upon request, an estimate will be provided before any chargeable repairs are attempted. A hard copy of a purchase order with the amount of the charge must be received by Microscan, either by mail or by FAX, before any equipment is returned. Warrantable products are repaired or replaced at no charge and returned freight prepaid. THIS EXPRESS WARRANTY EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PURPOSE. MICROSCAN SYSTEMS, INC., SHALL NOT BE LIABLE FOR WARRANTY IN ANY AMOUNT EXCEEDING THE PURCHASE PRICE OF THE GOODS. MICROSCAN SYSTEMS, INC., SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER IN CONTRACT, TORT, OR OTHERWISE. The buyer acknowledges that he/she is not relying on the seller's skill or judgment to select or furnish goods suitable for any particular purpose and that there are no warranties that extend beyond the description on the face hereof. This warranty extends only to the original purchaser, and shall not apply to any products or parts that have been subject to misuse, neglect, accident, or abnormal conditions or operations. Claims for damage in transit are directed to the freight carrier upon receipt.
ii
MS-610 Scanner User’s Manual
Page 3
Table of Contents List of Illustrations .................................................................................. iv List of Tables........................................................................................... v About the MS-610 Scanner.................................................................... vi About This Manual ................................................................................. vi Keystroke Entries................................................................................... vi Approvals .............................................................................................. vii Warning and Caution Summary............................................................ vii Safety Labels ........................................................................................viii
Chapter 1
Setup and Installation
Step 1 - Plan Scanning System ........................................................... 1-2 Step 2 - Verify Read Range and Scan Width....................................... 1-3 Step 3 - Calculate Number of Scans.................................................... 1-4 Step 4 - Attach Cabling ........................................................................ 1-6 Step 5 - Configure Scanner ................................................................. 1-8 Step 6 - Position Scanner and Label ................................................... 1-9 Step 7 - Do Read Rate Test............................................................... 1-10 Step 8 - Adjust Other Scanning Parameters...................................... 1-11 Step 9 - Install Scanner...................................................................... 1-13 Step 10 - Position Object Detector..................................................... 1-14 Operational Tips................................................................................. 1-15 Ground and Shield Considerations .................................................... 1-16
Chapter 2
Menu Configuration
Entering the Menu Configuration Program ......................................... 2-2 Using the Menu Configuration Program .............................................. 2-2 Saving Menu Changes ........................................................................ 2-4 Loss of Communications ..................................................................... 2-4 Defining Special Characters ............................................................... 2-4 Communications Menu ........................................................................ 2-5 Operations Menu ............................................................................... 2-11 Code Types Menu.............................................................................. 2-19 User Outputs Menu............................................................................ 2-26
Chapter 3
Serial Configuration
Summary of Serial Configuration Commands...................................... 3-2 Serial Configuration Command Format ............................................... 3-3 Concatenating Serial Commands ........................................................ 3-4 Loss of Communications...................................................................... 3-4 Trigger Filter Timing Value................................................................... 3-4 Communications Commands............................................................... 3-5 Protocol................................................................................................ 3-5 MS-610 Scanner User’s Manual iii
Page 4
Operations Commands........................................................................ 3-8 Code Types Commands.................................................................... 3-10 User Outputs Commands .................................................................. 3-12
Chapter 4
Operational Commands
Summary of Operational Commands ................................................. 4-2 Program Management Commands .................................................... 4-3 Device Control Commands ................................................................. 4-3 Code Type Commands ....................................................................... 4-4 Counter Commands ........................................................................... 4-4 Test Commands ................................................................................. 4-5 Status Commands .............................................................................. 4-5 Master Label Commands ................................................................... 4-5
Appendices Appendix A, Scanner Specifications ............................................... A-2 Appendix B, ASCII Table ................................................................ A-5 Appendix C, Orientation .................................................................. A-6 Appendix D, Defaulting the Scanner ............................................... A-8 Appendix E, Troubleshooting .......................................................... A-9 Appendix F, Optional Equipment .................................................. A-11 Appendix G, Bar Code Symbology ............................................... A-13 Appendix H, Interface Standards .................................................. A-14 Appendix I, Multidrop Communications ........................................ A-15 Appendix J, Glossary of Terms ..................................................... A-19
Index ................................................................................................ I-1
List of Illustrations Figure 1-1 System Diagram (without adapter box) .................................... 1-2 Figure 1-2 System Diagram (with adapter box) ......................................... 1-2 Figure 1-3 Ladder Orientation .................................................................... 1-4 Figure 1-4 Picket Fence Orientation .......................................................... 1-4 Figure 1-5 Angled Picket Fence Orientation .............................................. 1-5 Figure 1-6 Label Dimensions ..................................................................... 1-5 Figure 1-7 High Density 15-pin D-Sub Miniature Socket ........................... 1-6 Figure 1-8 Tilt, Skew, and Pitch Axes ........................................................ 1-9 Figure 1-9 Bottom Mounting Holes (not full size) ..................................... 1-13 Figure 1-10 Detector Right-Angle Orientation ......................................... 1-14 Figure 1-11 Detector Side Orientation ..................................................... 1-14 Figure 1-12 Grounding Diagram, Scanner-Host ...................................... 1-16 Figure 2-1 Configuration Program - Main Menu ........................................ 2-2 Figure 2-2 Communications Menu Structure ............................................. 2-5 Figure 2-3 Operations Menu Structure .................................................... 2-11 Figure 2-4 External Level Trigger Signals ............................................... 2-13 iv
MS-610 Scanner User’s Manual
Page 5
Figure 2-5 External Edge Trigger Signals ................................................ 2-13 Figure 2-6 Match Code Logic Diagram .................................................... 2-18 Figure 2-7 Code Types Menu Structure ................................................... 2-20 Figure 2-8 User Outputs Menu Structure ................................................. 2-26 Figure A-1 Dimensions................................................................................A-2 Figure A-2 Scan Range Width Graph ........................................................A-3 Figure A-3 Ladder Orientation ....................................................................A-6 Figure A-4 Picket Fence Orientation ..........................................................A-6 Figure A-5 Angled Picket Fence Orientation ..............................................A-7 Figure A-6 15-pin Socket (on back of scanner) ..........................................A-8 Figure A-7 25-pin Connector, RS-232 (J4) (on back of ADP box) .............A-8 Figure A-8 MS-520 Bottom Mounting Plate (not full size) ........................A-11 Figure A-9 Universal Stand ......................................................................A-12 Figure A-10 Typical Multidrop Network ....................................................A-15 Figure A-11 Polling Sequence .................................................................A-15 Figure A-12 Select Sequence ..................................................................A-16
List of Tables Table 1-1Read Ranges and Scan Widths.................................................. 1-3 Table 1-2 Pin Assignments ........................................................................ 1-6 Table 1-3 Scanner/MS-610 ADP (adapter) Pinouts ................................... 1-6 Table 1-4 Cable Distances ......................................................................... 1-7 Table 3-1 Summary of Serial Configuration Commands ............................ 3-2 Table 3-2 Protocol Commands .................................................................. 3-6 Table 4-1 Summary of Operational Commands.......................................... 4-2 Table A-115-pin Connector ........................................................................A-3 Table A-2 Scanner/MS-610 ADP (adapter) Pinouts.................................... A-3 Table A-3 Read Ranges and Scan Widths ................................................A-3 Table A-4 Status Lights ..............................................................................A-4 Table A-5 ASCII Table with Control Characters .........................................A-5 Table A-6 Troubleshooting Table ...............................................................A-9 Table A-7 Multidrop Address Characters .................................................A-16 Table A-6 Summary of Serial Configuration Commands.............................A-6 Table A-7 Summary of Operational Commands..........................................A-7 Table A-8 Multidrop Address Characters ....................................................A-8 Table A-9 Troubleshooting the Scanner....................................................A-12
MS-610 Scanner User’s Manual v
Page 6
About the MS-610 Scanner The MS-610 scanner integrates a scan head and decoder in a single unit. It uses a ten-sided mirror spinning at speeds of 200 scans per second to direct laser beams across bar code labels and converts reflected light to waveforms. The waveforms are then decoded and sent to the host as ASCII data.
About This Manual This manual provides complete information on setting up and installing the MS-610 (visible) and the MS-615 (infrared) scanner. Unless otherwise noted, references to the MS-610 apply also to the MS-615. Chapter 1 provides overall step-by-step instructions for setting up and installing the MS-610 scanner with specific “go to” references to other chapters and appendices. Chapter 2 provides instructions for configuring the MS-610 scanner by menu. Chapter 3 provides instructions for configuring the MS-610 scanner by serial command. Chapter 4 describes serial operational commands that can be used by the host. For specifications, see appendix A. The appendices also include reference tables, as well as other useful information relating to bar coding and the MS-610 scanner.
Keystroke Entries Keystrokes to be entered from your terminal are highlighted in bold, as in <D>, including a < left angle bracket symbol (unless redefined by Command Start Character command) and followed by a > right angle bracket symbol.
Approvals This equipment is approved for use by the following organizations: • CDRH (Center for Devices & Radiological Health) • UL (Underwriters Laboratories, Inc.) • CSA (Canadian Standards Association) • CISPR (International Special Committee on Radio Interference) • CE (European Community) vi
MS-610 Scanner User’s Manual
Page 7
• TüV (Technischer überwachungs-Verein) (MS-610 only) • FCC (Federal Communication Commission) • This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet Appareil numerique de la classe A respecte toutes les exigences du Reglement sur le material broilleur du Canada.
Warning and Caution Summary Caution: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his or her own expense For connection to a Listed direct plug-in power unit marked Class 2 and rated at 5 VDC @ 400 mA and ±12 VDC @ 80 mA. WARNING Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous laser light radiation exposure. WARNING Up to 5 mW of laser diode power can be present in the interior. Avoid opening the scan head. Inspect housing to verify that loose casings or panels do not allow access to laser light. WARNING The laser beam can be harmful to eyesight. Avoid direct eye con tact with the laser beam. Never point the beam at other people, or in a direction where people may be passing.
MS-610 Scanner User’s Manual vii
Page 8
Safety Labels Note: Back Label will carry a Class II designation when placed on an MS610 with 670 nm visible light and a Class I designation when placed on an MS-615 with 780 nm infrared light.
1201 S.W . 7th St.
Ren ton, W A 9 8055
2
LIS TE D UL 195 0 4K68
R
PO W ER 5V at 400 mA,
± 12 V a t 8 0 mA
CL AS S
G -READ SER IAL NU MBE R
Patent No. 5,239, 169
FIS NU MB ER
MANU FAC T UR E D 11-120 007-0 3
Top Label
Back Label sd sg g fs rt w s d f d g s re g fd d g t oi sg s g =9 g
Bottom Label viii
MAD E IN U.S .A.
MS-610 Scanner User’s Manual
Page 9
1
1–Setup and Inst.
Chapter
Setup and Installation
Chapter Contents Step 1 - Plan Scanning System ........................................................... 1-2 Step 2 - Verify Read Range and Scan Width....................................... 1-3 Step 3 - Calculate Number of Scans.................................................... 1-4 Step 4 - Attach Cabling ........................................................................ 1-6 Step 5 - Configure Scanner ................................................................. 1-8 Step 6 - Position Scanner and Label ................................................... 1-9 Step 7 - Do Read Rate Test............................................................... 1-10 Step 8 - Adjust Other Scanning Parameters...................................... 1-11 Step 9 - Install Scanner...................................................................... 1-13 Step 10 - Position Object Detector..................................................... 1-14 Operational Tips................................................................................. 1-15 Ground and Shield Considerations .................................................... 1-16
This chapter provides step-by-step instructions for setting up and installing the MS-610 scanner. Note: Bar code labels should meet minimum ANSI (American National Standards Institute) standards as specified in ANSI Bar Code Print Quality Guideline, X3.182-1990.
MS-610 Scanner User’s Manual
1-1
Page 10
Chapter 1
Setup and Installation
1–Setup and Inst.
1 Plan Scanning System
Before installing the MS-610 scanner you should sketch out a diagram of your scanning system, showing equipment, connector and cable types, and cable lengths. Figure 1-1 shows a possible scanning system setup without an adapter box. If using an adapter box, refer to figure 1-2. For wiring information, see Attach Cabling” on page 1-6. Bar-coded item flow Object Detector
RS-232 or RS-422
MS-610 15-pin cable Scanner
Host
To power supply MS-5000 Multidrop Concentrator
RS-485
Figure 1-1 System Diagram (without adapter box)
Bar-coded item flow
Optional ADP-232 or ADP-422/485 Junction Box
Object Detector
MS-610 Scanner
RS-232 or RS-422 RS-485
15-pin cable
MS-5000 Multidrop Concentrator
To power supply
Figure 1-2 System Diagram (with adapter box)
1-2
MS-610 Scanner User’s Manual
Host