Page 71
Mode and Data Switch Settings
Mode 2: Address Mode Switches
= On = Off
See mode 1 for switch settings.
Mode 3: Host Port Communications Mode Switches
= On = Off Data Switches
Baud Rate
Parity
Stop Bits
Data Bits
123
45
6
7
600
None
One
Seven
1200
Even
Two
Eight
2400
Odd
4800 9600 19200 38400
Mode 4: Preamble, Postamble Mode Switches
= On = Off
Data Switches
Postamble
1
2 Disable
Disable
Enable
Enable
MS-5000 Multidrop Concentrator User’s Manual
5–Profile Card
Preamble
5-5
Page 72
Chapter 5
Profile Card Configuration
Mode 5: Protocol, Host Port RS-422 = On
Mode Switches
= Off Data Switches
Protocol
RS-422
123
4 Point-to-Point
Disable
Point-to-Point with RTS/CTS
Enable
Point-to-Point with XON/XOFF Point-to-Point with RTS/XON Polling Mode D Multidrop User Defined User Defined Multidrop
Mode 6: Aux Port Mode Mode Switches
= On = Off
Data Switches
Aux Port Mode
12 Disable
5–Profile Card
Enable
5-6
MS-5000 Multidrop Concentrator User’s Manual
Page 73
Mode and Data Switch Settings
Mode 7: Aux Port Communications = On
Mode Switches
= Off Data Switches
Baud Rate
Parity
Stop Bits
Data Bits
123
45
6
7
2400
None
One
Seven
4800
Even
Two
Eight
9600
Odd
19.2K 38.4K
Mode 8: LAN Port Communications Mode Switches
= On = Off Data Switches
Baud Rate
Parity
Stop Bits
Data Bits
RS-422
123
45
6
7
8
600
None
One
Seven
Disable
1200
Even
Two
Eight
Enable
2400
Odd
4800
5–Profile Card
9600 19.2K 38.4K
MS-5000 Multidrop Concentrator User’s Manual
5-7
Page 74
Chapter 5
Profile Card Configuration
Mode 9: Host Port Turnaround Timeout Mode Switches
= On = Off
Mode 10: Host Port Intercharacter Timeout Mode Switches
= On = Off
Mode 11: LAN Port Turnaround Timeout Mode Switches
= On = Off
Mode 9, 10, and 11 will accept binary values from 1 to 250. To set these modes, multiply the desired number of seconds for timeout by 10 and enter the result in binary format. See mode 1 switch settings for timeout ranges from 0.1 seconds to 5 seconds. (Although not shown for mode 1, switches 7 and 8 are OFF for 1 through 50.) See “Binary Calculations” on page 5-9 for timeout ranges from 5.1 seconds to 25 seconds.
Mode 12: Blocking Factor1 Mode Switches
= On = Off
Mode 12 will accept binary values from 1 to 127. Values are set the same as mode 9, 10 and 11.
5–Profile Card
See mode 1 for switch settings.
1. See also, “<C>Send Partial Buffer to Host Command” on page 4-13 for related information.
5-8
MS-5000 Multidrop Concentrator User’s Manual
Page 75
Binary Calculations
Mode 13: RTS/CTS and XON/XOFF Mode Switches
= On = Off
Data Switches
RTS/CTS
XON/XOFF
1
2 Disable
Disable
Enable
Enable
Mode 14: Full Screens Mode Switches
= On = Off
Data Switches
Fulls Screens
1 234 Disable Enable
Binary Calculations Data switch settings for values 51 to 255 must be determined with binary calculation. (Specifically, the timeout values for 51 to 255 in mode 9 and various serial trigger character selections in mode 10.)
MS-5000 Multidrop Concentrator User’s Manual
5-9
5–Profile Card
The eight data switches on the profile card represent the eight data bits that define any number from 0 to 255 in binary format. To convert a number to its binary equivalent: 1. Determine which decimal equivalent (1, 2, 4, 8, 16, 32, 64, 128) is the largest number not exceeding the number to convert. 2. Put a one (1) above that number to indicate an ON position.
Page 76
Chapter 5
Profile Card Configuration For example, table 5-2 shows the calculation process for the number 250. The first one (1) is placed in the eighth bit column over the number 128, since that is the largest possible decimal equivalent to use. Table 5-2 Calculating Binary Conversion Data Switches
1
2
3
= On
4
5
6
7
8
Data Switches (bit representation) Data Switch Settings
1
1
1
1
1
1
Binary Code
2
10 26 58 122
Remainder Numbers 250
1
= Off
2
4
8
16 32 64 128
<--- Number to Convert Decimal Equivalent
3. Subtract the decimal equivalent from the original number. 4. Place the remainder above the next largest decimal equivalent that does not exceed the remainder number. 5. Put a one (1) above that number. 6. Continue this process until the remainder equals zero (0), as follows: 250 -128=122, -64=58, -32=26, -16=10, -8=2, -2=0
5–Profile Card
OFF positions on the data switches result from: • Decimal equivalent numbers passed over because they are greater than the remainder (the third bit in table 5-2), • Decimal equivalent numbers not used because the formula has terminated with a remainder of zero (0) (the first bit in table 5-2).
5-10
MS-5000 Multidrop Concentrator User’s Manual
Page 77
Contents Appendix A, MS-5000 Specifications ........................................... A-2 Appendix B, Quick Reference Tables ........................................... A-3 Appendix C, Defaulting the MS-5000 .......................................... A-6 Appendix D, Ground and Shield Considerations .......................... A-7 Appendix E, Terminal Resistor ..................................................... A-9 Appendix F, Interface Standards ................................................ A-10 Appendix G, Glossary of Terms ................................................. A-11
MS-5000 Multidrop Concentrator User’s
A-1
Appendices
Appendices
Page 78
Physical Characteristics:
Communications Settings
Length: 6.2 in. (157.5 mm) Height: 1.36 in. (34.5 mm)
Host Port Communications Interfaces: RS-232, RS-422, RS-485 ACSII Character Format: 7 or 8 Data Bits Stop Bits: 1 or 2 Baud Rates: 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K Selectable Parity: Odd, Even, or None Protocols: Point-to-Point, Polling Mode D, Multidrop, User Defined, and User Defined Multidrop LAN Port Communications Interface: 4-wire, RS-485, RS-422 ACSII Character Format: 7 or 8 Data Bits Stop Bits: 1 or 2 Baud Rates: 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K I/O Port: 6-pin, 6-wire modular Protocols: Multidrop, User Defined Multidrop (up to 50 devices per concentrator) Auxiliary (Monitor) Port Communications Interface: RS-232 ACSII Character Format: 7 or 8 Data Bits Stop Bits: 1 or 2 Baud Rates: 2400, 4800, 9600, 19.2K, 38.4K I/O Port: 9-pin, D-subminiature plug Protocol: Point-to-Point
0.5"(12.7)
Width: 6.61 in. (167.9 mm) Weight: 16 oz. (453 grams) 5.6" (142.24) Front
1.85" (46.99) CAUTION: The6-32mountingscrews should not extend more than 0.12 in. (3 mm) into the mounting holes.
6.2" (157.48)
2.5" (63.5)
6/32 threads (6.35mm) 4 places
Inches (mm)
Rear
5.8" (147.32) 0.030" (7.62)
5.8" (147.32)
Electrical Characteristics
5.2" (132.08)
3.8" (96.52)
0.160" (4.06) DIA (4 places)
4.5" (114.30)
Front
Figure A-1 MS-5000 Dimensions
A-2
+12 VDC @ 40 mA max., 20 mV p-p max. allowed ripple –12 VDC @ 40 mA max., 20 mV p-p max. allowed ripple +5 VDC @ 300 mA max., 200 mV p-p max. allowed ripple
Operating Environment Measurements in inches (millimeters)
1.0" (25.4)
Appendices
Appendix A, MS-5000 Specifications
Operating Temperature: 32° to 113°F (0° to 45°C) Storage Temperature: –58° to 158°F (-50° to 70°C) Humidity: 0% to 95% (non-condensing)
Status Lights Three LEDs (light emitting diodes) on the front panel of the concentrator serve as visual indicators to verify that it is operating correctly. IND 1: Flashes green each time data is sent to the host. IND 2: Illuminates red whenever the concentrator is in a ready state or is polling the connected devices. When this light goes off, a data-buffer-full condition exists and the concentrator is no longer polling the devices. PWR: Illuminates red when the power switch is in the ON position.
MS-5000 Multidrop Concentrator User’s Manual
Page 79
Quick Reference Tables Appendices
Appendix B, Quick Reference Tables Table A-1 ASCII Table with Control Characters
Dec
Hex
Mne
Ctrl
Dec
Hex
Ch
Dec
Hex
Ch
Dec
Hex
Ch
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
^@ ^A ^B ^C ^D ^E ^F ^G ^H ^I ^J ^K ^L ^M ^N ^O ^P ^Q ^R ^S ^T ^U ^V ^W ^X ^Y ^Z ^[ ^\ ^] ^^ ^_
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
SP ! " # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
64 65
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
96 97 98
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ ý
66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
MS-5000 Multidrop Concentrator User’s Manual
99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
A-3
Page 80
Appendices
Table A-2 Summary of Serial Configuration Commands
Command
Effect
51<Kadata>CR 51<Kbdata>CR
Host Port Baud, Parity, Stop Bits, and Data Bits Host Port RS-422
51<Kcdata>CR 51<Kddata>CR 51<Kedata>CR 51<Kfdata>CR 51<Kgdata>CR 51<Khdata>CR 51<Kidata>CR 51<Kjdata>CR 51<Kkdata>CR 51<Kldata>CR 51<Kmdata>CR 51<Kndata>CR 51<Kodata>CR 51<Kpdata>CR 51<Kqdata>CR 51<Krdata>CR 51<Ksdata>CR 51<KIdata>CR 51<KJdata>CR
LRC Preamble Postamble Host Protocol Blocking Factor Host Port Turnaround Timeout Host Port Intercharacter Timeout RTS/CTS XON/XOFF LAN Port Baud, Parity, Stop Bits, and Data Bits LAN Port RS-422 LAN Port Turnaround Timeout, Number of Devices Auxiliary Mode Aux Port Baud, Parity, Stop Bits, and Data Bits Full Screens Battery-backed RAM (optional) Poll Response Timeout Time and Date Setting Time and Date Output
Table A-3 Summary of MS-5000 Operational Commands
Command 51<A>CR 51<B>CR 51<C>CR 51<D>CR 51<Z>CR 51<&>CR 51<#>CR
Effect Software reset, but preserve data in buffers Reset, including data in buffers Partial buffer to host Launch Configuration Program Save current configuration for power up Upload to Current Date and Time Upload to Software Part Number
Less than < and greater than > symbols are included as part of the commands. There are no spaces between any fields, but commas are used to separate data fields. Configuration commands are shown here with one data field; however, the actual number of data fields varies by command.
A-4