The text of a manual · part 7 of 10

MS-5000 Multidrop Concentrator User's Manual, pages 61 to 70

Pages 61 to 70 of 94

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-5000

Page 61

Serial Commands new address (^Y) must be assigned in the User Defined command <KF7,^Y>.

Preamble Prepend up to five ASCII characters to decoded data. Format: 51<Kdfirst data field,second data field>CR Second Data Field: Send up to five ASCII characters except a null (00H).

First Data Field: 0 = Disable 1 = Enable

Example: To enable Preamble and send an FF (form feed) character, enter 51<Kd1,^L>CR.

Postamble Append up to two ASCII characters to decoded data. Format: 51<Kefirst data field,second data field>CR First Data Field: 0 = Disable 1 = Enable

Second Data Field: Send up to five ASCII characters except a null (00H).

Example: To enable Postamble and send an FF (form feed) character, enter 51<Ke1,^L>CR.

LRC The exclusive OR of all characters following SOM (start of message) up to and including the EOM (end of message).

4–Operations.

Format: 51<Kcstatus>CR 0 = Disable 1 = Enable Example: To enable LRC, enter 51<Kc1,^L>CR.

RTS/CTS Ready to Send and Clear to Send Format: 51<Kjstatus>CR 0 = Disable 1 = Enable Example: To enable RTS/CTS, enter 51<Kj1>CR.

MS-5000 Multidrop Concentrator User’s Manual

4-9

Page 62

Chapter 4

Serial Commands

XON/XOFF Transmitter on/off Format: 51<Kkstatus>CR 0 = Disable 1 = Enable Example: To enable XON/XOFF, enter 51<Kk1>CR.

Blocking Factor Number of records that can be buffered for batch delivery to the host. Format: 51<Kgblocking factor>CRr1 Any number from 1 to 127. Default is 1. Example: To change Blocking Factor to 5, enter 51<Kg5>CR.

Full Screens Toggle between full menu view and command line only view. Format: 51<Kqstatus>CR 0 = Disable 1 = Enable Example: To enable Full Screens, enter 51<Kq1>CR. Battery-backed RAM2 Saves data in RAM for power-up.

4–Operations.

Format: 51<Krstatus>CR 0 = Disable 1 = Enable Example: To enable Battery-backed RAM, enter 51<Kr1>CR.

1. See also, “<C>Send Partial Buffer to Host Command” on page 4-13 for related information. 2. Battery-backed RAM is optional.

4-10

MS-5000 Multidrop Concentrator User’s Manual

Page 63

Serial Commands

Time Keeping Commands Time and Date Settings Set current time and date settings. Format: 51<KIhour,minute,second,DOW,month,day,year> Hour: 0 to 23 Month 1 to 12

Minute: 0 to 59. Day 1 to 31

Second 0 to 59 Year 0 to 99

DOW (day of week) Sun = 1 Wed = 4 Sat = 7 Mon = 2 Thu = 5 Tue = 3 Fri = 6

Time and Date Output Set format for time and date output. <KJtime output,date output,time separator> time output: date output: time separator: 0 = Disabled 0 = Disabled Any ASCII character 1 = Hrs:Min:Sec 1 = MM/DD/YYYY 2 = Hrs:Min:Sec:Hundreds 2 = Day.MM/DD/YYYY 3 = DD/MM/YYYY 4 = Day.DD/MM/YYYY

4–Operations.

MS-5000 Multidrop Concentrator User’s Manual

4-11

Page 64

Chapter 4

Serial Commands

Operational Commands <A> Reset, not Save Reset, not clear data buffers, and not save changes for power-up. Format: 51<A>CR Example: To send the same command with an <A> reset, enter 51<Kq1><A>CR.

<B> Reset and Clear, not Save Reset, clear data buffers, and not save changes for power-up. Format: 51<B>CR Example: To enable Full Screens and do a <B> reset, enter 51<Kq1><B>CR. Example: To send it as two separate sequential commands, enter 51<Kq1>CR 51<B>CR.

<Z> Save for Power-up Reset, clear data buffers, and save for power-up. Format: 51<Z>CR Example: To reset and save to non-volatile RAM, enter 51<Kq1><Z>CR. Example: Saving Concentrator Changes. To save changes made by host command to the concentrator for power up, enter 51<Z>CR.

4–Operations.

Example: Saving Decoder Changes. To save changes made by host command to a decoder for power up, enter the decoder’s address (if in polled mode) and <Z>CR. For example, to save changes to decoder 03 for power up,enter 03<Z>CR.

Concatenating Serial Commands You can concatenate (add together) commands to a single address in a single string or data block to a maximum of 127 characters to a concentrator or 64 characters to a decoder. For example, 51<Ki66><Kh88><Ko0><B>CR changes Host Intercharacter Timeout to 66 ms, Host Turnaround Timeout to 88 ms, disables Auxiliary Port, and resets and clears the data buffers. See “Multiple Select Commands” on page 2-6. You cannot send a command (single or concatenated) to more than one address. For this, you must use separate command strings and conform to the Intercharacter Timeout setting. 4-12

MS-5000 Multidrop Concentrator User’s Manual

Page 65

Serial Commands

<C>Send Partial Buffer to Host Command Sends a partial buffer to the host. It “collects” any remaining data from the concentrator when Blocking Factor is set to more than one. Format: 51<C>CR Example: For example, if Blocking Factor is set to 5, sending 51<C>CR at 22 records will release a batch of 2 records to the host. See “Blocking Factor” on page 4-10.

<&> Uploading Current Time Uploads the current date and time to the host with the 51 address prepended. Format: 51<&>CR

<#> Uploading Part Number Uploads the part number of the software in the concentrator to the host with the 51 address prepended. Format: 51<#>CR

<D> Enter Menu Configuration Program Command Enters the Menu Configuration Program. See “Entering the Menu Configuration Program” on page 3-2 and Table 4-2, “Summary of MS-5000 Operational Commands,” on page 4-2. Format: 51<D>CR

4–Operations.

MS-5000 Multidrop Concentrator User’s Manual

4-13

Page 66 read from a scan by OCR; it may hold reading errors

Chapter 4 Serial Commands no i= ie} s © = o 2. ° v

4-14 MS-5000 Multidrop Concentrator User’s Manual

Page 67

Chapter

5

Profile Card Configuration Profile Card Configuration

Chapter Contents Summary of Profile Card Modes...........................................................5-2 Operating Instructions...........................................................................5-3 Mode and Data Switch Settings............................................................5-4 Binary Calculations ...............................................................................5-9

Most of the menu configuration changes to the MS-5000 concentrator can also be made with the profile card.

MS-5000 Multidrop Concentrator User’s Manual

5-1

5–Profile Card

The profile card, available from Microscan as an accessory (P/N 97100001-XX), is not essential to the operation of the concentrator but can speed up configuration and is particularly useful for copying configuration from one device to another and for configuring devices that have been given multidrop addresses.

Page 68

Chapter 5

Profile Card Configuration

Summary of Profile Card Modes Table 5-1 Profile Card Mode Descriptions for the MS-5000 Mode

Parameter Write-to-Device Function

0

Read Function Default Menu

1

Write & Assign Address

2

Assign Multidrop Address

3

4 5 6 7

8

9 10

5–Profile Card

11 12 13 14

5-2

Baud Rate Parity Stop Bits Data Bits Preamble Postamble Protocol RS-422 Aux Port Baud Rate Parity Stop Bits Data Bits Baud Rate Parity Stop Bits Data Bits RS-422 Host Port Turnaround Timeout Intercharacter Timeout LAN Port Turnaround Timeout Blocking Factor RTS/CTS XON/XOFF Full Screens

Function Downloads (writes) all of the configuration parameters stored in the profile card to the connected concentrator. Uploads configuration data from the volatile RAM of the concentrator to the non-volatile RAM of the profile card. Sets unit to the default configuration settings. Enters menu program while the concentrator is in polled mode. Combines the write function of mode 0 with the address function of mode 2. Downloads a user-selected multidrop address as well as all of the configuration parameters stored in the profile card. Assigns user-selected multidrop addresses to the concentrator by using data switches 1-6. Binary representation of the multidrop address is used (the range is 1 to 50). Defines Baud Rate for the host port. Defines Parity for the host port. Defines Stop Bits for the host port. Defines Data Bits for the host port. Enables/disables Preamble. Enables/disables Postamble. Defines the communications protocol. Enables/disables RS-422 for the host port. Sets Aux. Port operation mode. Defines Baud Rate for the auxiliary port. Defines Parity for the auxiliary port. Defines Stop Bits for the auxiliary port. Defines Data Bits for the auxiliary port. Defines Baud Rate for the LAN port. Defines Parity for the LAN port. Defines Stop Bits for the LAN port. Defines Data Bits for the LAN port. Enables/disables RS-422 for the LAN port. Defines the time for Host Port Turnaround Timeout. The range is 1-250 ms. Sets the waiting period between individual characters transmitted from the host. The range is 1-250 ms. Defines the time for LAN Port Turnaround Timeout. The range is 1-250 ms. Buffers records from decoders and delivers them to the host in batches. Controls data flow. Controls data flow. Enables/disables Full Screens.

MS-5000 Multidrop Concentrator User’s Manual

Page 69

Operating Instructions

Operating Instructions The profile card obtains all operating voltages from the concentrator. 1. With the concentrator OFF, connect the DECODER end of the profile card to the HOST connector of the concentrator (see figure 5-1). Turn concentrator ON. 2. Set the mode and data switches on the profile card. Data switches are on the left, mode switches on the right. Note: Be sure ALL of the data switch settings are correct for the selected mode before pressing the load button.

HOST LAN

DATA

DECODER

POWER

MONITOR

O

LOAD

O

N

1 23 4 MODE

OFF

PROFILE CARD

N 1 2 3 4 5 6 7 8

ON

TERMINAL

Figure 5-1 Profile Card Connection

To maintain RS-232 communication between the host and the concentrator with the profile card, connect a cable between the TERMINAL end of the profile card and the host. MS-5000 Multidrop Concentrator User’s Manual

5-3

5–Profile Card

3. Press the LOAD button. 4. A beeper will sound. This initializes the change and saves it to non-volatile RAM for access on power-up. 5. When the configuration is complete, turn off the power to the concentrator and remove the profile card.

Page 70

Chapter 5

Profile Card Configuration

Mode and Data Switch Settings Mode 0:

Write, Read, Default, Menu

Mode Switches

= On = Off

Data Switches

1234

Write Read Default Menu

Mode 1: Copy Configuration and Assign Address Mode Switches

= On = Off

5–Profile Card

Data Switchesa

Address

Address

Address

Address

123456

123456

123456

123456

1

14

40

2

15

28

41

3

16

29

42

4

17

30

43

5

18

31

44

6

19

32

45

7

20

33

46

8

21

34

47

9

22

35

48

10

23

36

49

11

24

37

50

12

25

38

13

26

39 a. Also used for mode 2, 9, 10, 11, and 12.

5-4

27

MS-5000 Multidrop Concentrator User’s Manual