For the Microscan MS-5000

Page 81

Quick Reference Tables

Multidrop Address 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Poll Character ASCII HEX ^\ ^^ SP " $ & ( * , . 0 2 4 6 8 : < > @ B D F H J L

1C 1E 20 22 24 26 28 2A 2C 2E 30 32 34 36 38 3A 3C 3E 40 42 44 46 48 4A 4C

Select Character ASCII HEX ^] ^! # % ' ) + / 1 3 5 7 9 ; = ? A C E G I K M

1D 1F 21 23 25 27 29 2B 2D 2F 31 33 35 37 39 3B 3D 3F 41 43 45 47 49 4B 4D

Multidrop Address 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50

Poll Character ASCII HEX N P R T V X Z \ ^ ` b d f h j l n p r t v x z | ~

MS-5000 Multidrop Concentrator User’s Manual

4E 50 52 54 56 58 5A 5C 5E 60 62 64 66 68 6A 6C 6E 70 72 74 76 78 7A 7C 7E

Appendices

Table A-4 Multidrop Address Characters

Select Character ASCII HEX O Q S U W Y [ ] _ a c e g i k m o q s u w y { } ý

4F 51 53 55 57 59 5B 5D 5F 61 63 65 67 69 6B 6D 6F 71 73 75 77 79 7B 7D 7F

A-5

Page 82

Defaulting will reset the concentrator parameters to the original factory settings. Defaulting might be necessary if communications between the concentrator and another device are interrupted or if using incompatible equipment (for example, a terminal is set to communicate at 9600 baud, but the concentrator is configured at 38.4 K baud). Note: There are no menu options or host commands for resetting configuration. Note: Power must be available to the concentrator during default procedures.

Using the Profile Card

Shorting Pins 7 and 11

OFF

DECODER

Insert the end of the profile card labeled “DECODER” into the concentrator’s host connector and turn the concentrator ON. Set all four mode switches to OFF, set number 3 data switch to ON (as shown in figure A-2), and press the LOAD button. (See “Write, Read, Default, Menu” on page 5-4.) Listen for two beeps in succession (the second louder LOAD than the first). If the beeps do ON not occur as described, repeat PROFILE CARD the default procedure. O

N 1 2 3 4 5 6 7 8

DATA

O

N

1 23 4

TERMINAL

Appendices

Appendix C, Defaulting the MS-5000

MODE

If a profile card is not accessible, it is necessary to default Figure A-2 Profile Card Default Setting the concentrator by shorting pins 7 and 11. CAUTION: Be sure to short the correct pins. Shorting the wrong pins can cause serious damage to the unit. 1. Locate pins 7 and 11 on the host connector (figure A-3) and mark. (Use a small length of light wire approximately 4 inches, 18 to 26 gauge for shorting.) 2. Momentarily short pins 11 and 7. Listen for a series of short beeps. 3. Within 3 seconds, short pins 11 and 7 again. A longer beep should be heard. If not, repeat the process. Note: Using switching power supPin 11 Pin 7 plies as a power source is not recommended due to excessive ripple characteristics. Figure A-3 Host Connector Default Pins (on back of concentrator)

A-6

MS-5000 Multidrop Concentrator User’s Manual

Page 83

Ground and Shield Considerations

Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes. RS-232 signals have a common signal ground (pin 7). Pin 7 is normally connected to pin 1 (chassis ground) in the concentrator; however, under certain conditions (e.g., when potential differences exist between power outlet grounds) signal and chassis grounds can be isolated from each other inside the concentrator by Microscan technicians. Any data line, as necessary, can be shielded. If used, shielding should be isolated from the concentrator and grounded only to the host earth ground.

Noise Interference Noise interference can be minimized if cabling subject to noise interference is twisted and/or shielded or encased in grounded conduit, and the conduit or shielding (“drain” line) is grounded only to earth ground at the host, as shown in figure A-4. 1. Examine the shielding connection at or near the concentrator cable connector. 2. Cut the shielding connection as required.

Ground Loops Ground loops, signal degradation due to different ground potentials in communicating devices, can be eliminated or minimized by ensuring that the host, concentrator(s), scanner(s), decoder(s), and their power supplies are connected to a common earth ground. In some cases it may be possible to fully isolate devices by insulating mounting under each device and using the optional ground wire in the LAN cable rather than the power supply cable to ground the device chassis. (Power supplies that provide earth ground to the chassis should not be used here without modifications.) Ground loops can be avoided as shown in figure A-4. In this method, the optional ground wire (see Figure A-4 “Network Grounding Diagram” on page A-8) is disconnected at each device, and each device chassis is earthgrounded through the power supply. The power supply must provide a reliable earth ground connection. MS-5000 Multidrop Concentrator User’s Manual

A-7

Appendices

Appendix D, Ground and Shield Considerations

Page 84

Appendices

H ost

S h ie ldin g C o m m u n ic a tio n s C a b le E a rth G ro u n d

C o n ce n tra to r

D ecoder

D ecoder

D ecoder

D ecoder

C o n ce n tra to r

Figure A-4 Network Grounding Diagram

A-8

MS-5000 Multidrop Concentrator User’s Manual

Page 85

Terminal Resistor Appendices

Appendix E, Terminal Resistor To guarantee signal integrity, a 68 ohm resistor is necessary at the last device in a network. With MS-3000 Decoders: Terminal resistors are built into the MS-3000 decoders and are activated by setting an internal DIP switch (no. 1 DIP switch S2) to ON as shown in figure A-5.

Power Switch Front of MS-3000

DS-3

DS-2

C6

R1

C1 C5 C2

R2

S1

R3 C3

RN1

ON

C4

R4

S2 4 3 2 1

U1

# 1 DIP switch set to ON position

Figure A-5 DIP Switch (in last MS-2000/MS-3000)

With Other Devices: Terminal resistors can be installed externally by wiring the resistor into the last T-junction box or by wiring within the connector of the last scanner (or decoder) in line. Terminal resistors are wired between the receive lines of the last scanner. Caution: Setting the DIP switch termination resistor on the MS-3000 decoder and then moving the decoder to a different location will cause the trunk cable to end at the new location.

MS-5000 Multidrop Concentrator User’s Manual

A-9

Page 86

Appendices

Appendix F, Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. With Microscan devices, selection of interface is made by pin assignment and, in the case of the host communications, by software switching between RS-232 and RS-422. Microscan devices use RS-232, RS-422, and RS-485 multidrop.

RS-232 RS-232 defines an interface between two devices such as, for example, the concentrator and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (15.24 m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.

RS-422 RS-422, unlike RS-232, measures signals differentially that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219 m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line. It can be used wherever RS-232 is used.

RS-485 RS-485, like RS-422, can transmit up to 4000 feet (1219 m) using differential voltages but unlike RS-422, its transmitters are turned off until a request for data is received from the host. RS-485 is used exclusively in Multidrop protocol. Note: “Communications Menu” in chapter 3, “Menu Configuration,” has additional information on standards.

A-10

MS-5000 Multidrop Concentrator User’s Manual

Page 87

Glossary of Terms

Active. Status of an address that is assigned to an on-line multidrop device. AWG. Abbreviation for American Wire Gauge. This is a standard measuring system for wire sizes, listed from 0 (biggest) to 40 (smallest). A 26 AWG is equivalent to .0159 in. (0.405 mm) in diameter. Bar Code. Data that has been encoded into an array of parallel bars and spaces of varying widths. Baud Rate. The term used to describe the number of discrete conditions or signal events per second. In RS-232 and RS-422/485 systems, baud rate is the same as bits per second (bps). Blocking Factor. A parameter of the concentrator which defines the size of buffer records (bar codes, counters, etc.) from decoders that will be batched to the host. Concentrator. Intermediary device which communicates with other devices, and relays data from those devices to the host as well as commands from the host to the devices. Configuration. The method used to change factory default settings for operational features to match a specific application. Configuration can be done through menu selection, or with serial commands. Connector. Physical device (plug or socket) on unit or cable to provide in/ out connectivity for various circuits and pins. Counter. Memory space provided to keep track of read cycle events. Data. ASCII text such as label information, no read messages, and host serial commands. Decoder. A device that analyzes digital input provided by the scan head and translates it into bar code information. Default. The original factory settings. Defaulting. Act of resetting the reader to the original factory settings. DTE (Data Terminal Equipment). Devices that act as a data source or destination. EPROM. Erasable, programmable, read only memory. Host. DTE device used to configure, control, and collect data from concentrators, decoders, and other devices. Inactive. Status indicating that no devices are present at that address. Intercharacter Timeout. The time that the concentrator will wait between individual characters transmitted from the host. LAN. Local Area Network. MS-5000 Multidrop Concentrator User’s Manual

A-11

Appendices

Appendix G, Glossary of Terms

Page 88

Appendices

Menu Configuration. The process of changing factory default settings via a sequence of menus displayed on a terminal monitor. Monitor. DTE device which can echo data from the host or decoder, and be used in configuration. Multidrop. A communications protocol for networking two or more decoders or other devices with a concentrator (or controller) and characterized by the use of individual device addresses and the RS-485 standard. Null. A non-printed character that acts as a space-holder. Object Detector. A photo electric device used to sense the presence or absence of an object. Operational Commands. Serial commands from the host to the reader that control current operating parameters, counters, master label operations, and program management that are not stored in non-volatile RAM. Parity. An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd. Point-to-Point. A protocol consisting of a single communications event, typically used to connect a bar code reader to a CRT terminal or a host computer. Polled Protocol. A communication protocol in which the host requests information from the concentrator by means of an address. Polling Request. In a typical multidrop network, a polling request occurs when the concentrator polls the devices under it by substituting the ASCII hex values associated with each poll address. Port. Logical circuit for data entry and exit. (One or more ports may be included within a single connector.) Protocol. The rules for communication between devices, providing a means to control the orderly communication of information between linked devices. RAM. Random Access Memory. Memory that is lost after power is recycled to the unit. Relay Driver. A TTL signal sent by the decoder. The output is determined by the relay driver selection during configuration. ROM. Read Only Memory. Memory that cannot be changed. Scan Head. The module that projects laser light on bar code labels and receives reflected light back. This device changes the analog signal to a digital representation of the bar code and outputs it to a decoder.

A-12

MS-5000 Multidrop Concentrator User’s Manual

Page 89

Glossary of Terms

MS-5000 Multidrop Concentrator User’s Manual

A-13

Appendices

Select Commands. Configuration or operation instructions originating from the host and consisting of to decoders and other devices that are configured in Multidrop. Serial Commands. The classification of commands that are generated by the following structure (specific to a multidrop system): an address (51 for concentrators), a less than (<) symbol, specific command datum, a greater than (>) symbol, and a CR (carriage return). Serial Configuration. The method of changing factory default settings via command strings. The structure for a multidrop system consists of an address (51 for concentrators), a less than (<) symbol, a capital K, a parameter letter, configuration data, a greater than (>) symbol, and a CR (carriage return). Trigger. A signal, either external or serial, that initiates the read cycle and causes the decoder to expect label input. Turnaround Timeout. The time that the concentrator will wait between its request for data and a device’s response in a poll or select sequence.

Page 90

Appendices A-14

MS-5000 Multidrop Concentrator User’s Manual