Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 8 of 11

MS-3 CCD Reader User's Manual, pages 71 to 80

Pages 71 to 80 of 106

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-3

Page 71

Chapter

Terminal Mode

6 Chapter Contents Terminal Window.........................................................................................6-2 Find Function...............................................................................................6-3 Macros.........................................................................................................6-4 Terminal Window Functions ........................................................................6-5

This section describes the terminal window and macro functions. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

MS-3 CCD Reader User’s Manual

6-1

Page 72

Terminal Window

Terminal Window To use the terminal mode, click on the Terminal button. You will see the following window:

Type in text here to find in terminal window

Copy, paste, and save Clear screen

Macro List on this bar

Terminal screen

Click on Macros arrow to Add Macro, Remove Macro or Edit Macro

Click on Macro to Run

Figure 6-1 Terminal Window The terminal screen allows you to enter serial commands (in red) from the macro box, by copying, or directly from your keyboard. The terminal screen also displays bar code data or information from the reader (in blue). You can also right click in the terminal screen to bring up a handy option box.

6-2

MS-3 CCD Reader User’s Manual

Page 73

Chapter 6 Terminal Mode

Find Function The Find box allows you to enter text strings to be searched for in the terminal window. For example a series of bar codes have been scanned into the terminal view and you want to determine if a particular bar code starting with ABC has been read. 1. Type ABC into the Find box.

2. Press Enter. The first instance of ABC will be high-lighted in the terminal window. 3. Press the F3 key to search again for the next instance of ABC. 4. Press Shift-F3 to search for the previous instance of ABC.

MS-3 CCD Reader User’s Manual

6-3

Page 74

Macros

Macros Macros can be stored in a macro selection bar, edited in a separate window, and executed by clicking on the macro name.

Click on Next Row to see the next row of macros

Click on the first arrow here to Add Macro or Default Macros. When you default macros, the entire macros set is restored to their original macro commands.

Click here to edit a macro.

When you click on the macro name, the macro is executed in the terminal window. If this is a command, the command is also sent to the reader at the same time it is displayed.

Editing a Macro When you click the arrow next to a any macro and select Edit, the following appears:

You can edit an existing macro or type in a new macro name and define it in the Macro Value text box. Click OK.

6-4

MS-3 CCD Reader User’s Manual

Page 75

Chapter 6 Terminal Mode

Terminal Window Functions Right-click on the terminal window to display the following: • Copy selected text to clipboard. • Paste from terminal or computer text. • Clear all text in terminal window. • Select All text in the terminal window. • Save... brings up a save as dialog box. • Change Font... of data text, brings up a text dialog. • Change Echo Font... to change typed in text or commands. • Change Background Color of terminal window. • Default Settings changes all the above back to default settings. The pulldown Terminal menu has Capture and Save Current Text as well as the functions defined above. • Capture lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened. You can select Pause to interrupt the capture flow or Stop to end the flow and open the file. • Save Current Text... saves all text in the terminal window to a text file of your choice.

MS-3 CCD Reader User’s Manual

6-5

Page 76

Terminal Window Functions

6-6

MS-3 CCD Reader User’s Manual

Page 77

Appendices

Chapter Contents Appendix A General Specifications .........................................................A-2 Appendix B Electrical Specifications .......................................................A-4 Appendix C Connectivity .........................................................................A-5 Appendix D Serial Configuration Commands ........................................A-10 Appendix E Serial Command Format ....................................................A-12 Appendix F ASCII Table ........................................................................A-14 Appendix G Defaulting/Saving/Resetting ..............................................A-15 Appendix H Object Detector ..................................................................A-17 Appendix I Formulas for Number of Decodes .......................................A-18 Appendix J Operational Tips .................................................................A-20 Appendix K Glossary of Terms ..............................................................A-21

MS-3 CCD Reader User’s Manual

A-1

Page 78

General Specifications

Appendix A, General Specifications Mechanical

Height: 0.85” (21.6 mm) Width: 1.75” (44.5 mm) Depth: 1.75” (44.5 mm) Weight: 2.0 oz. (57 g)

.85" (21.6 mm)

Environmental

Enclosure rating: IP54, category 2 Operating temperature: –30° to 60° C (–22° to 140° F) Humidity: Up to 90% (non-condensing) Operating life: 40,000 hours at 25° C Ambient light: Works in any lighting conditions, from 0 to 100,000 lux

Beam

.31" (7.8 mm) 1.75" (44.5 mm) 1.41" ( 35.8 mm) .22" (5.6 mm)

CE MARK

General immunity for light industry: EN 55024: 1998 ITE Immunity Standard Radiated and Conducted Emissions of ITE equipment: EN 55022:98, ITE disturbances class A.

2X M3 x 0.5 5.3 mm depth

.90" (22.8 mm)

1.75" (44.5 mm)

Optics

Slotted CCD Scanning Parameters

Scan rate (decoded mode): 270 scans per second, auto-adaptive Minimum X dimension: down to 0.05 mm (2 mil) on Code 39 Depth of field: 0 to 49.2 cm (19.4”) Bar code width: up to 18 cm (7”) on 0.3 mm (12 mil) resolution code Print contrast: down to 20% Scan width angle: 48° nominal Pitch: ±50°; Skew: ±40° Symbol contrast: 25% min. @ 650 nM Connector

3 ft. (914 mm) cable terminated with 15-pin D-sub socket connector Communications

RS-232 TTL, Wedge

A-2

MS-3 CCD Reader User’s Manual

Figure A-1 MS-3 CCD Dimensions

Laser Emission

Side

Back

.90" (22.9 mm)

2.25" (57.2mm) 2X M3x0.5 5mm MIN DEPTH

10° 2.40" (61.0mm)

.63" (16.0mm)

.85" (21.6mm)

1.25" (31.8mm)

.45" (11.4mm)

Figure A-2 MS-3 CCD Right Angle Dimensions

Page 79

Appendices Read Ranges cm in. 5 cm

5

0 in. 2

1

1

5

0

5

10

0

5 15

5

0

10

5

35

10

4

30

.020" .508 mm

3

5

2

2

.010" .254 mm

25

.020" .508 mm

20 .010" .254 mm

1 .005" .127 mm

.0075" .191 mm

15 5

0

10 cm in. Range

5

0

10

0 0 in. cm Range

Note: The above graphs are not drawn to the same scale.

High Density Ranges

Low Density Ranges

Figure A-3 MS-3 CCD Read Ranges

Safety Certifications

FCC, UL/cUL, CE, BSMI ISO 9001:2000 Certification No. 03-1212 Product specifications are given for typical performance at 23°C (74°F) using grade A symbols. Some performance characteristics may vary at high temperatures or other environmental extremes. © 2006 Microscan Systems, Inc. Specifications subject to change.

MS-3 CCD Reader User’s Manual

A-3

Page 80

Electrical Specifications

Appendix B, Electrical Specifications Reader Pin Assignments Table A-1 MS-3 CCD Host Connector, 15-pin Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A-4

Host/ RS232 Power +5 VDC TxD RxD Power/Signal ground NC RTS NC NC Trigger (NPN) CTS NC NC Chassis ground NC NC

In/Out

MS-3 CCD Reader User’s Manual

In Out In

5

10

Out

In In

15

11 6

1

Caution: • Be sure all cables connected BEFORE applying power. • Always power down BEFORE