The text of a manual · part 9 of 13
MS-2 CCD Reader User's Manual, pages 81 to 90
Pages 81 to 90 of 125
The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-2
Page 81
Symbologies
UPC-A as EAN-13 (UPC/EAN) Definition: Serial Cmd: Default: Options:
When enabled, UPC-A will be transmitted as EAN-13. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as UPC-A,EAN-8 as EAN-13> Enabled 0 = Disabled 1 = Enabled
UPC-E as UPC-A (UPC/EAN) Definition: Serial Cmd: Default: Options:
When enabled, UPC-E will be transmitted as UPC-A. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as UPC-A,EAN-8 as EAN-13> Disabled 0 = Disabled 1 = Enabled
EAN-8 as EAN-13 (UPC/EAN) Definition: Serial Cmd: Default: Options:
When enabled, EAN-8 will be transmitted as EAN-13. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as UPC-A,EAN-8 as EAN-13> Disabled 0 = Disabled 1 = Enabled
MS-2 CCD Reader User’s Manual
5-19
Page 82
Symbology Identifier
Symbology Identifier Definition:
Serial Cmd: Default: Options:
Symbology Identifier is a standard prefix set of characters that identifies the symbol type. When enabled, the reader analyzes and identifies the symbology and adds a three-character identifying prefix to the data: • ] (closed bracket character) indicating the presence of a symbology identifier. • A, C, E, F, G, I, e, P, M (A = Code 39; C = Code 128/EAN-128; E = UPC/EAN; F = Codabar; G = Code 93; I = Interleaved 2 of 5; e = GS1 DataBar (RSS); P = Plessey Code; M = MSI Code) • Modifier <K450,0,symbology identifier status> Disabled 0 = Disabled 1 = Enabled
Explanation of Modifiers for Code 39, Codabar, and I-2/5 • For Code 39, Codabar, and Interleaved 2 of 5, the modifier indicates Check Character and Check Character Output status. • For Code 39 only, Full ASCII must be enabled to see modifiers 4, 5, and 7. Modifier
Check Character
0 1 3 4 5 7
Disabled Enabled Enabled Disabled Enabled Enabled
Check Character Output N/A Enabled Disabled N/A Enabled Disabled
Full ASCII conversion performed (Code 39 only) No No No Yes Yes Yes
Example: ]A5 indicates a Code 39 symbol with Check Character and Check Character Output enabled and Full ASCII conversion performed.
Explanation of Modifiers for Other Symbologies • For Code 128/EAN-128, a 1 indicates EAN-128; otherwise the modifier is 0. • For all other symbologies, the modifier is 0.
5-20
MS-2 CCD Reader User’s Manual
Page 83
6 Terminal Contents Terminal Window.......................................................................................................................... 6-2 Find .............................................................................................................................................. 6-3 Send ............................................................................................................................................. 6-4 Macros.......................................................................................................................................... 6-5 Terminal Window Menus.............................................................................................................. 6-6
This section describes the Terminal window and Macro functions in ESP.
MS-2 CCD Reader User’s Manual
6-1
Page 84
Terminal Window
Terminal Window Click this button to display the Terminal view. The following view will appear: Copy, paste, save
Type text here to find matching text in the Terminal window.
Type serial commands here, or directly in the terminal screen.
Clear screen Terminal screen
Click on desired Macro to run.
Macros listed on this bar.
Click on arrows to Add Macro, Remove Macro, or Edit Macro.
The Terminal allows you to send serial commands to the reader by typing commands in the Send text field or directly in the Terminal screen, by copying and pasting, or by using Macros. The Terminal screen also displays symbol data or information from the reader. You can right-click on the screen to bring up a menu of several options for managing data in the Terminal view. 6-2
MS-2 CCD Reader User’s Manual
Page 85
Terminal
Find The Find function allows you to enter text strings to be searched for in the Terminal window. For example, data from a series of symbols has been sent to the Terminal and you want to determine if a particular symbol whose data begins with “ABC” has been decoded. 1. Type “ABC” into the Find field.
2. Press Enter. The first instance of “ABC” will be highlighted in the Terminal window. 3. Click the Find button to the left of the text field to locate additional instances of “ABC”.
MS-2 CCD Reader User’s Manual
6-3
Page 86
Send
Send The Send function allows you to enter serial commands and then send them to the reader. 1. Type the command into the Send box.
2. Press Enter to send the command to the reader. 3. Click the Send button to the left of the text field to send the command again.
6-4
MS-2 CCD Reader User’s Manual
Page 87
Terminal
Macros Macros can be stored in a macro selection bar, edited in a separate window, and executed by clicking on the macro name.
Click on Next Row to see the next row of macros
Click on the first arrow here to see Add Macro or Default Macros. When you default macros, the entire macros set is restored to their original macro commands.
Click on subsequent arrows to edit macros.
When you click on the macro name, the macro is executed in the Terminal window. If the macro is a command, it is sent to the reader at the same time that it is displayed.
Editing a Macro When you click the arrow next to any macro and select Edit Macro, the following dialog appears:
You can edit an existing Macro Name or Macro Value by typing a new name or value in the corresponding text field and clicking OK.
MS-2 CCD Reader User’s Manual
6-5
Page 88
Terminal Window Menus
Terminal Window Menus Right-click on the Terminal window to display the following menu: • Copy selected text to clipboard. • Paste from Terminal or other text. • Clear all text in Terminal window. • Select All text in the Terminal window. • Save... brings up a Save As dialog. • Change Font... of text in Terminal; brings up a Font dialog. • Change Echo Font... to change typed text; brings up a Font dialog. • Enable Echo enables Echo text (typed by user). • Change Background Color of Terminal window. • Non-Printable Characters allows you to hide non-printable characters, or to show them in Standard or Enhanced format. • Default Settings returns all of the above settings to default. • Keyboard Macros allows you to create new keyboard macro commands that can be sent from function keys (F2, F4, F5, etc.)
Terminal Dropdown Menu The dropdown Terminal menu has Capture Text, Save Current Text, Send File, Find Next, and Find Previous functions, as well as the same functions defined above. • Capture Text... lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened. You can select Pause to interrupt the capture flow or Stop to end the flow and open the file. • Save Current Text... saves all text in the Terminal window to a text file. • Find Next searches for a user-defined section of text in the Terminal. • Find Previous operates in the same way as Find Next, but searches backward through Terminal text.
6-6
MS-2 CCD Reader User’s Manual
Page 89
7 Utilities Contents Serial Utility Commands ............................................................................................................... 7-2 Differences from Default............................................................................................................... 7-3 Firmware....................................................................................................................................... 7-4 Device Control .............................................................................................................................. 7-7 Default/Reset/Save....................................................................................................................... 7-8 Reader Status Request ................................................................................................................ 7-9
Utility commands are generally commands that are performed during reader operations to perform miscellaneous operations on reader hardware. Serial utility commands are not prefaced with a ”K” and a numeric value, nor do they require an initialization command (<A> and <Z>). They can be entered from ESP’s Terminal or Utilities views.
MS-2 CCD Reader User’s Manual
7-1
Page 90
Serial Utility Commands
Serial Utility Commands Note: For a list of all K commands, see Serial Configuration Commands on page A-6. Type Part Number Device Control
Default/Reset/Save
Command <#> <H> <I> <A> <Z> <Zrd>
Reader Status Request Trigger
7-2
<K?> <char>
Name Display Firmware Part Number Enable Reader Disable Reader (Continuous, external trigger) Reset (does not save for power-on) Save Current Settings for Power-On Recall Microscan Default Parameters and Save for Power-On Configuration Command Status Serial Trigger Character
MS-2 CCD Reader User’s Manual