Page 71
Symbologies
Symbol Length #1 (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:
Useful in applications where I 2/5 symbols of a specific length are required. The Symbol Length # 1 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. <K472,status,check character status,check character output,symbol length #1,symbol length #2> 10 0 to 32
Symbol Length #2 (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:
Useful in applications where I 2/5 symbols of a specific length are required. The Symbol Length # 2 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. <K472,status,check character status,check character output,symbol length #1,symbol length #2> 6 0 to 32
Range Modes (Interleaved 2 of 5) Variable Length To set for any length, Symbol Length # 1 and Symbol Length # 2 must both equal zero.
Minimum Length To set for minimum length, both Symbol Length # 1 and Symbol Length # 2 must be equal to each other and be any number other than zero.
Fixed Length To set for a fixed length, Symbol Length #1 and Symbol Length #2 must not be equal to each other.
MS-2 CCD Reader User’s Manual
5-9
Page 72
Code 128/EAN 128
Code 128/EAN 128 Usage: Definition:
Serial Cmd: Default: Options:
Code 128 is a smaller symbology useful in applications with limited space and high-security requirements. A very dense alphanumeric symbology. It encodes all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge. <K474,status,0,minimum symbol length,1,1,0,application record separator character> Disabled 0 = Disabled 1 = Enabled
Minimum Symbol Length (Code 128/EAN 128) Usage: Definition:
Serial Cmd: Default: Options:
Minimum Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. This specifies the exact number of characters that the reader will recognize (this does not include start, stop, and check characters). The reader ignores any symbol not having the specified length. <K474,status,0,minimum symbol length,1,1,0,application record separator character> 0 0 to 32
Application Record Separator Character (Code 128/EAN 128) Definition: Serial Cmd: Default: Options:
5-10
This is an ASCII character that serves as a separator in formatted output. <K474,status,0,minimum symbol length,1,1,0,application record separator character> NUL Any ASCII character (7 bit)
MS-2 CCD Reader User’s Manual
Page 73
Symbologies
Code 93 Usage: Definition: Serial Cmd: Default: Options:
Used in some clinical applications. Code 93 is a variable-length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces. <K475,status,0,minimum symbol length> Disabled 0 = Disabled 1 = Enabled
Minimum Symbol Length (Code 93) Definition:
Serial Cmd: Default: Options:
Specifies the minimum number of characters that the reader will recognize, not including the start and stop check characters. The reader ignores any symbol smaller than the specified length. Note: When setting Minimum Symbol Length to any value other than 0, add 1 to account for a reserved space. For example, if your symbol has 3 characters, set Symbol Length to 4. <K475,status,0,minimum symbol length> 10 0 to 32
MS-2 CCD Reader User’s Manual
5-11
Page 74
GS1 DataBar (RSS)
GS1 DataBar (RSS) Note: GS1 DataBar symbologies were previously known as “Reduced Space Symbology”, or “RSS”.
DataBar-14 (RSS-14) Note: DataBar-14 was previously known as “RSS-14”. Usage: Definition:
Serial Cmd: Default: Options:
Used in the grocery, retail, and prescription drug industries where 14-digit EAN item identification may be needed. DataBar-14 is a minimum length symbology that encodes 14 digits, including a 1-digit indicator. DataBar-14 is 96 modules wide. It can be stacked in two rows, it can read omnidirectionally if printed in full height, or horizontally if height-truncated for small marking. <K482,status> Disabled 0 = Disabled 1 = Enabled
DataBar Limited (RSS Limited) Note: DataBar Limited was previously known as “RSS Limited”. Usage: Definition: Serial Cmd: Default: Options:
DataBar Limited is designed to be read by laser and CCD readers. It is not recommended for omnidirectional slot scanners. Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional. <K483,status> Disabled 0 = Disabled 1 = Enabled
DataBar Expanded (RSS Expanded) Note: DataBar Expanded was previously known as “RSS Expanded”. Usage: Definition:
Serial Cmd: Default: Options: 5-12
Used to encode primary and supplementary data in retail point-of-sale and other applications. DataBar Expanded is a variable length symbology that can encode supplementary information in addition to the 14-digit EAN item identification number and is capable of encoding up to 74 numeric or 41 alphabetic characters. <K484,status> Disabled 0 = Disabled 1 = Enabled MS-2 CCD Reader User’s Manual
Page 75
Symbologies
MSI Code Status (MSI Code) Usage: Definition: Serial Cmd: Default: Options:
Used for inventory control and the identification of storage containers and locations in warehouse environments. MSI Code is a numeric, continuous symbology in which each character consists of four bits in a binary format. <K486,status,check character mode,check character output status, 0,minimum symbol length> Disabled 0 = Disabled 1 = Enabled
Check Character Mode (MSI Code) Definition: Serial Cmd: Default: Options:
This field is set to perform a Modulus 10 calculation by default. It can also be set to perform a Double Modulus 10 calculation. <K486,status,check character mode,check character output status, 0,minimum symbol length> Modulus 10 1 = Modulus 10 2 = Double Modulus 10
Check Character Output Status (MSI Code) Definition: Serial Cmd: Default: Options:
When this field is enabled, the reader will output the check digit with symbol data. When disabled, the reader will not output the check digit with symbol data. <K486,status,check character mode,check character output status, 0,minimum symbol length> Disabled 0 = Disabled 1 = Enabled
Minimum Symbol Length (MSI Code) Definition: Serial Cmd: Default: Options:
This field specifies the minimum number of characters the reader will recognize, including a check character. <K486,status,check character mode,check character output status, 0,minimum symbol length> 6 0 to 32
MS-2 CCD Reader User’s Manual
5-13
Page 76
Plessey Code
Plessey Code Status (Plessey Code) Usage: Definition: Serial Cmd: Default: Options:
Used primarily in library and retail applications. Plessey Code consists of pairs of wide and narrow bars representing binary data which, taken in units of 12, define hexadecimal characters. <K487,status,check character output status,0,minimum symbol length> Disabled 0 = Disabled 1 = Enabled
Check Character Output Status (Plessey Code) Definition: Serial Cmd: Default: Options:
When this field is enabled, the check character will be output with symbol data. When disabled, the check character will not be output with symbol data. <K487,status,check character output status,0,minimum symbol length> Disabled 0 = Disabled 1 = Enabled
Minimum Symbol Length (Plessey Code) Definition: Serial Cmd: Default: Options:
5-14
This field specifies the minimum number of characters the reader will recognize, including a check character. <K487,status,check character output status,0,minimum symbol length> 0 0 to 32
MS-2 CCD Reader User’s Manual
Page 77
Symbologies
Industrial 2 of 5 Status (Industrial 2 of 5) Usage: Definition:
Serial Cmd: Default: Options:
Used primarily in warehouse sortation, photo finishing, and the sequential numbering of airline tickets. Microscan recommends that Industrial 2 of 5 always be used with fixed symbol length settings in any application. Symbol Length # 1 and Symbol Length # 2 can both be set to 0 to allow the reader to decode Industrial 2 of 5 symbols of varying lengths. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Check Character Status (Industrial 2 of 5) Definition: Serial Cmd: Default: Options:
When this field is enabled, a check character is added. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Check Character Output Status (Industrial 2 of 5) Definition: Serial Cmd: Default: Options:
When this field is enabled, the check character will be output with symbol data. When disabled, the check character will not be output with symbol data. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Format (Industrial 2 of 5) DefinitionL Serial Cmd: Default Options:
Defines the number of start and stop check characters. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> 3 start / 3 stop 0 = 3 start / 3 stop 1 = 2 start / 2 stop
MS-2 CCD Reader User’s Manual
5-15
Page 78
Industrial 2 of 5
Symbol Length # 1 (Industrial 2 of 5) Definition:
Serial Cmd: Default: Options:
This field specifies the number of characters that the reader will recognize, including start and stop characters and check characters. The reader ignores any symbol with fewer than the specified number of characters. Because Industrial 2 of 5 is a continuous symbology, it is prone to substitution errors. Therefore, a symbol length must be defined and a symbol must contain an even number of characters. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> 10 0 to 32
Symbol Length # 2 (Industrial 2 of 5) Definition:
Serial Cmd: Default: Options:
This field specifies the number of characters that the reader will recognize, including start and stop characters and check characters. The reader ignores any symbol with fewer than the specified number of characters. Because Industrial 2 of 5 is a continuous symbology, it is prone to substitution errors. Therefore, a symbol length must be defined and a symbol must contain an even number of characters. <K488,status,check character status,check character output status,format, symbol length #1,symbol length #2> 6 0 to 32
Range Modes (Industrial 2 of 5) Variable Length To set for any length, Symbol Length # 1 and Symbol Length # 2 must both equal zero.
Minimum Length To set for minimum length, both Symbol Length # 1 and Symbol Length # 2 must be equal to each other and be any number other than zero.
Fixed Length To set for a fixed length, Symbol Length #1 and Symbol Length #2 must not be equal to each other.
5-16
MS-2 CCD Reader User’s Manual
Page 79
Symbologies
UPC/EAN UPC-A Status (UPC/EAN) Usage: Definition:
Serial Cmd: Default: Options:
Used primarily in point-of-sale applications in the retail industry. UPC (Universal Product Code) is a minimum length, numeric, continuous symbology. UPC can have two- or five-digit supplemental bar code data following the normal code. The UPC Version A (UPC-A) symbol is used to encode a 12-digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. EAN is the European version of the UPC symbology and is used in European market applications. When enabled, the reader will read UPC-A symbols. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as UPC-A,EAN-8 as EAN-13> Enabled 0 = Disabled 1 = Enabled
UPC-E Status (UPC/EAN) Definition: Serial Cmd: Default: Options:
This field is enabled by default and will decode all UPC-E symbols. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as UPC-A,EAN-8 as EAN-13> Enabled 0 = Disabled 1 = Enabled
EAN-8 Status (UPC/EAN) Definition: Serial Cmd: Default: Options:
This field is enabled by default and will decode all EAN-8 symbols. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as UPC-A,EAN-8 as EAN-13> Enabled 0 = Disabled 1 = Enabled
MS-2 CCD Reader User’s Manual
5-17
Page 80
UPC/EAN
EAN-13 Status (UPC/EAN) Definition: Serial Cmd:
Default: Options:
This field is enabled by default and will decode all EAN-13 symbols. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as UPC-A,EAN-8 as EAN-13> Enabled 0 = Disabled 1 = Enabled
Supplementals Required (UPC/EAN) Definition: Serial Cmd: Default: Options:
A supplemental is a 2 or 5-character symbol appended to the main symbol. When enabled, the reader decodes supplemental symbol data that has been appended to the standard UPC or EAN symbol. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as UPC-A,EAN-8 as EAN-13> Disabled 0 = Disabled 1 = Enabled
Supplemental 2 Status (UPC/EAN) Definition: Serial Cmd: Default: Options:
A 2-character symbol appended to the main symbol. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as UPC-A,EAN-8 as EAN-13> Disabled 0 = Disabled 1 = Enabled
Supplemental 5 Status (UPC/EAN) Definition: Serial Cmd: Default: Options:
5-18
A 5-character symbol appended to the main symbol. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as UPC-A,EAN-8 as EAN-13> Disabled 0 = Disabled 1 = Enabled
MS-2 CCD Reader User’s Manual