Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 10 of 13

MS-2 CCD Reader User's Manual, pages 91 to 100

Pages 91 to 100 of 125

The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-2

Page 91

Utilities

Differences from Default Clicking the Differences from Default button will cause ESP to check all stored configuration settings and compare them to default settings. All settings that are different than default will appear in the left column (shown below), and descriptions of those settings will appear in the right column. Click this button for a list of ESP configuration settings that are different than default settings.

Send configuration settings to the reader without saving by clicking Send to Reader.

Click Save As to save the report as plain text or a tab-delimited text file.

Send configuration settings to the reader and save in ESP by clicking Send and Save.

• To save the Differences from Default report, either as plain text or as a tab-delimited text file, click Save As. • Click Send and Save to send the settings to the reader and save them, or Send to Reader to send the settings without saving them. Important: The use the Differences from Default feature, you must connect to the reader and Receive Reader Settings via the Send/Recv button on the toolbar.

MS-2 CCD Reader User’s Manual

7-3

Page 92

Firmware

Firmware Firmware Update Application code versions are specific to your MS-2. Consult with your sales representative before downloading application code. If needed, application code will be sent to you in the form of a *.mhx file. Contact Microscan’s help desk if you have difficulty downloading application code to the MS-2: helpdesk@microscan.com.

Downloading Application Code to the MS-2 1. Connect to the MS-2 via ESP. 2. Verify your current firmware using Firmware Verification in ESP Utilities. 3. Power-off the reader by detaching the reader cable from the IC-3USB adapter (if you are connected by USB) or IC-332 adapter (if you are connected by RS-232). 4. Attach the plug end of the Firmware Upgrade Adapter (61-000143-01) to the reader cable.

Plug End

Socket End

Firmware Upgrade Adapter (61-000143-01)

5. Attach the socket end of the Firmware Upgrade Adapter to the IC-3USB adapter (if you are connected by USB) or IC-332 adapter (if you are connected by RS-232) and power-on the reader. 6. Click the Start button in ESP Utilities to open the firmware update utility. Click the Start button in ESP Utilities to open the firmware update utility.

7. Select the reader from the Target Device dropdown menu. 8. Select 8MHz from the Crystal Frequency dropdown menu.

(Continued on next page) 7-4

MS-2 CCD Reader User’s Manual

Page 93

Utilities 9. Click Open, select the appropriate firmware file (a .mhx file) and click OK. 10. Click the Set Environment button to bring up the COM Port menu.

11. Select the appropriate COM Port and click OK. 12. Click the Download button. When the following dialog appears, cycle power to the reader (turn power off and then back on) and then click OK to continue.

13. Click OK again once firmware is downloaded. 14. Click the Erase button to clear old firmware.

15. Click OK again when you see the dialog stating that old firmware has been erased. 16. Click the Full Operation(D+E+B+P) button. When the dialog shown in step 12 appears, cycle power to the reader (turn power off and then back on), and then click OK to complete the download process.

17. Click OK again when you see the dialog stating that the firmware download is complete. 18. Detach the Firmware Upgrade Adapter (61-000143-01) and re-connect the MS-2 in its original configuration. 19. Verify installation of the new firmware using Firmware Verification in ESP Utilities. 20. If the firmware update procedure fails, check hardware and pinout connectivity, and repeat the procedure. Caution: Do not interrupt power or disconnect the host cable while download is in progress. Be sure that each download is complete before moving on to the next. Important: When updating firmware, be sure that the application code and boot code versions are mutually compatible. MS-2 CCD Reader User’s Manual

7-5

Page 94

Firmware

Firmware Verification Request Part Number by ESP ESP allows you to send a request to the MS-2 for the application code part number. 1. Click the Firmware tab. 2. From the dropdown menu to the left of the Request Part No. button, select App Code. 3. The application code part number will be displayed in the text field to the right of the Request Part No. button.

7-6

MS-2 CCD Reader User’s Manual

Page 95

Utilities

Device Control Disable Reader Usage: Definition: Serial Cmd:

This feature is useful during extended periods when no symbols are being decoded, or when the reader is being configured. Sending <I> will turn the reader off. <I> Note: <I> only disables Continuous Read and the external trigger. Serial triggers will activate a read cycle.

Enable Reader Definition: Serial Cmd:

Sending <H> allows the reader to trigger on any available trigger source. <H>

MS-2 CCD Reader User’s Manual

7-7

Page 96

Default/Reset/Save

Default/Reset/Save Understanding and controlling your reader’s active, saved, and default settings is critical to its successful operation. Serial Cmd

ESP (first, right-click in any menu tree)a

Reset

<A>

Save to Reader, Send No Save

Save Current Settings for Power-On

<Z>

Save to Reader, Send and Save

Recall Microscan Default Parameters and Save for Power-On

<Zrd>

No

Save for Power-on

Reset (not saved for power-on)

Function a. When you right-click in a menu tree and select Default Current Menu Settings or Default All ESP Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the reader itself, you need to follow up with a Save to Reader, Send and Save command.

Reset Reset (“A” command) affects only current settings (active memory) and does not save for power-on.

Save for Power-On Power-on parameters (“Z” commands) are saved, recalled, and loaded into current parameters when power is cycled to the reader. Important: The following commands must be followed by a <Z> to be saved for power-on: Host Protocol, Baud Rate, Data Bits, Stop Bits, Parity, Trigger Characters (Delimited, Start, Stop), Preamble, Postamble, and No Read Message. All other parameters are saved for power-on without a <Z>. However, a <Zrd> affects all parameters.

7-8

MS-2 CCD Reader User’s Manual

Page 97

Utilities

Reader Status Request <K?> Configuration Command Status This is the fastest way to learn the reader’s current configuration. Sending this request will return the current settings of all commands, starting with the lowest K command value and ending with the highest K command value.

MS-2 CCD Reader User’s Manual

7-9

Page 98

Reader Status Request

7-10

MS-2 CCD Reader User’s Manual

Page 99

Appendices Contents Appendix A General Specifications .............................................................................................. A-2 Appendix B Electrical Specifications ............................................................................................ A-5 Appendix C Serial Configuration Commands............................................................................... A-6 Appendix D Communications Protocol......................................................................................... A-9 Appendix E ASCII Table............................................................................................................. A-10 Appendix F Operational Tips...................................................................................................... A-11 Appendix G Using an External Trigger....................................................................................... A-12 Appendix H Glossary of Terms .................................................................................................. A-13

MS-2 CCD Reader User’s Manual

A-1

Page 100

General Specifications

Appendix A, General Specifications Mechanical Height: 0.85” (21.6 mm) Width: 1.75” (44.5 mm) Length: 1.75” (44.5 mm) Weight: 2 oz. (57 g)

Design Sensor: CCD linear image sensor Optics: 660 nm visible LED

Scanning Performance Scan Rate: 220 scans/sec Min. X Dimension: Down to 0.084 mm (3.3 mil) on Code 39 Depth of Field: 0.8 to 325 mm (12.8”) Symbol Width: Up to 178 mm (7”) on 0.5 mm (20 mil) symbol

Standard Case, Side

Communications Interface: RS-232

Connector Type: 3-foot cable terminated with 15-Pin High Density D-sub Socket Connector

Symbologies UPC/EAN, Code 39, Code 128/EAN-128, Interleaved 2 of 5, Industrial 2 of 5, Codabar, Code 93, MSI Code, Plessey Code, GS1 DataBar (RSS)

Standard Case, Base

Environmental Operating Tempurature: –20° to 50° C (–4° to 122° F) Storage Tempurature: –20° to 60° C (–4° to 140° F) Relative Humidity: 20% to 85% (non-condensing) Ambient Light: Works in any lighting conditions, from 0 to 70,000 lux

CE Mark Immunity Designed for: EN 55024:1998 ITE Immunity Standard Radiated and Conducted Emissions Designed for: EN 55022:1998 ITE Disturbances Class A

Right Angle Case, Side

Electrical Power: 5V +/– 5%, 300 mV p-p max. ripple, 150mA @ 5V (typ.)

Discrete I/O Trigger Input: 4.7 to 24V rated (0 µA @ 5V – 600 µA @ 0V)

Right Angle Case, Base

MS-2 CCD Reader Dimensions A-2

MS-2 CCD Reader User’s Manual