Page 101
Appendices Read Ranges
Low Density Narrow-bar-width .005” (.127 mm) .010” (.254 mm) .015” (.38 mm) .005” (.127 mm) .010” (.254 mm) .020” (.508 mm)
High Density Read Range High Density .9 – 2.1” (23 – 53 mm) .8 – 3.3” (20 – 84 mm) .8 – 4.3” (20 – 109 mm) Low Density 1.4 – 3.3” (36 – 84 mm) 1.3 – 7.4” (30 – 188 mm) 1.3 – 12.8” (30 – 325 mm)
Scan Width 2.0” (51 mm) at 1.7" (43 mm) 2.5” (64 mm) at 2.9" (74 mm) 3.0” (76 mm) at 3.5" (84 mm) 2.4” (61 mm) at 2.8” (71 mm) 4.2” (107 mm) at 5.8” (147 mm) 7.0” (178 mm) at 10.8” (274 mm)
Note: All values are based on a Grade B Code 39 symbol.
MS-2 CCD Reader User’s Manual
A-3
Page 102
General Specifications FIS Options MS-2 CCD Reader CCD Reader, Standard, Low Density, RS-232, 5VDC CCD Reader, Right Angle, Low Density, RS-232, 5VDC CCD Reader, Standard, High Density, RS-232, 5VDC CCD Reader, Right Angle, High Density, RS-232, 5VDC
FIS-0002-0001G FIS-0002-0002G FIS-0002-0003G FIS-0002-0004G
Safety Certifications FCC, UL/cUL, CE, RoHS/WEEE
ISO Certification ISO 9001:2000 Certified Quality Management System Issued by TUV USA Inc., Member of TUV NORD Group, Cert. No. 06-1080
©2008 Microscan Systems, Inc. All rights reserved. Specifications subject to change. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Performance characteristics may vary at high temperatures or other environmental extremes. Warranty–One year limited warranty on parts and labor. Extended warranty available.
A-4
MS-2 CCD Reader User’s Manual
Page 103
Appendices
Appendix B, Electrical Specifications Power: 5V +/– 5%, 300 mV p-p max. ripple, 150mA @ 5V (typ.)
Host Connector / Pin Assignments 15-Pin High Density D-sub Socket Connector
Pin
Host RS-232
In/Out
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
+5 Power TxD RxD GND N/C RTS N/C Firmware Upgrade Trigger In CTS N/C N/C CHASSIS GND N/C N/C
In Out In
MS-2 CCD Reader User’s Manual
Out In (Active Low) In (Active Low) In
A-5
Page 104
Serial Configuration Commands
Appendix C, Serial Configuration Commands Note: For a list of utility commands such as read rate requests, device control options, and reader status requests, see Serial Utility Commands on page 7-2. Communications Host Port Connections Host Port Protocol Preamble Postamble Read Cycle Trigger Mode Serial Trigger Character No Decode Timeout Decodes Before Output Number of Symbols Start Trigger Character Stop Trigger Character Time Between Identical Decodes Reader Setup No Read Message Symbologies Symbology Identifier Code 39 Codabar
Interleaved 2 of 5 Code 128/EAN 128 Code 93 DataBar-14 (RSS-14) DataBar Limited (RSS Limited) DataBar Expanded (RSS Expanded) MSI Code Plessey Code Industrial 2 of 5 UPC/EAN
A-6
<K100,baud rate,parity,stop bits,data bits> <K140,protocol> <K141,status,preamble characters> <K142,status,postamble characters> <K200,trigger mode> <K201,serial trigger character> <K220,0,seconds> <K221,decodes before output> <K222,number of symbols> <K229,start character> <K230,stop character> <K503,time between identical decodes> <K522,shutter speed,minimum speed,maximum speed> <K714,status,No Read message> <K450,0,symbology identifier status> <K470,status,check character status,check character output status, 0,0,minimum symbol length,full ASCII set> <K471,status,0,start/stop match output status,0,symbol length status, symbol length,check character status,check character output status> <K472,status,check character status,check character output status, symbol length #1,symbol length #2> <K474,status,0,minimum symbol length,1,1,0,application record separator character> <K475,status,0,minimum symbol length> <K482,status> <K483,status> <K484,status> <K486,status,check character mode,check character output status, 0,minimum symbol length> <K487,status,check character output status,0,minimum symbol length> <K488,status,check character status,check character output status, format,symbol length #1,symbol length #2> <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status, supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13,UPC-E as UPC-A,EAN-8 as EAN-13>
MS-2 CCD Reader User’s Manual
Page 105
Appendices
Serial Command Format Serial commands are of two types: utility and configuration.
Rules that apply to both Utility and Configuration commands • A less than < and greater than > character enclose the commands. • Commands and data are “case-sensitive.” That is, characters must be entered as upper or lower case, as specified.
Serial Utility Commands These are sent during operations and are not followed by <A> or <Z>.
Serial Configuration “K” Commands These begin with a single “K” character followed by a 3-digit numeric value, data fields, and an initializing command, as follows: <Knumeric value,data,data,...etc.><initializing command> An initializing command <A> or <Z> may follow the command. A <Z> initializes the reader’s memory and saves for power-on; an <A> initializes the reader’s memory but does not save for power-on. For example, to enable UPC and save the change for power-on, send <K473,1><Z>. To change Baud Rate to 4800 and reset without saving changes for power-on, send <K100,3><A>.
Serial Configuration Command Conventions • All data fields (except the last) must be followed by a comma without a space. • Typically, NUL cannot be used. The characters <, >, and , can be used, but only if entered as hex pairs. • All fields preceding a modified field must be included unless there is no change in the preceding fields. • If there is no change in preceding fields, then commas alone can be entered in these fields. For example, if only the last field in the command <K100,4,1,0,1> is changing, it can be entered as <K100,,,,1>. • All fields following a modified field can be omitted. For example, to change Baud Rate to 4800 without changing the other host port paramters, send <K100,3>.
Concatenating Configuration Commands Commands can be concatenated (added together) in a single string. For example, <K100,4><K222,1><K470,0><A> sets the Baud Rate to 9600, enables Multiple symbol mode, disables Code 39, and resets the data buffers (without saving the changes for power-on).
MS-2 CCD Reader User’s Manual
A-7
Page 106
Serial Configuration Commands
Configuration Command Status Request To learn the reader’s current configuration, send the Configuration Command Status command: <K?>.
Entering Control Characters in Serial Commands To enter control characters within a serial command, hold down the Ctrl key while typing the desired character. Example: To enter a carriage return and line feed (^M^J), enter <K141,1,CTRL-m CTRL-j>.
A-8
MS-2 CCD Reader User’s Manual
Page 107
Appendices
Appendix D, Communications Protocol Communications Protocol Command Table Protocol Command (Mnemonic displayed on menu)
Control Characters (Entered in menu or serial command)
Hex Value
Effect of Command
RES
^D
04
Reset
REQ
^E
05
Request
EOT
^D
04
Reset
STX
^B
02
Start of Text
ETX
^C
03
End of Text
ACK
^F
06
Acknowledge
NAK
^U
15
Negative Acknowledge
XON
^Q
11
Begin Transmission
XOFF
^S
13
Stop Transmission
MS-2 CCD Reader User’s Manual
A-9
Page 108
Communication Protocol Commands
Appendix E, ASCII Table Dec 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
A-10
Hex 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
Mne NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
Ctrl ^@ ^A ^B ^C ^D ^E ^F ^G ^H ^I ^J ^K ^L ^M ^N ^O ^P ^Q ^R ^S ^T ^U ^V ^W ^X ^Y ^Z ^[ ^\ ^] ^^ ^_
Dec 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
Hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
Ch SP ! “ # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
Dec 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
Hex 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
Ch @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
Dec 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
Hex 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
Ch ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ D
MS-2 CCD Reader User’s Manual
Page 109
Appendices
Appendix F, Operational Tips Cleaning The MS-2 CCD Reader has a hard-coated window that should only be cleaned with alcohol (100% isopropyl).
Mounting When mounting the MS-2 CCD Reader, do not insulate the stand mount. The bottom panel is the hottest part of the reader and metal-to-metal contact is necessary for heat dissipation.
MS-2 CCD Reader User’s Manual
A-11
Page 110
Using an External Trigger
Appendix G, Using an External Trigger Two types of inputs are used on Microscan readers. 5 volt devices have NPN trigger inputs. 10-28 volt devices have optoisolated inputs and outputs.
5 Volt Devices To trigger a 5 volt device, the input has to be pulled down to “signal ground” (NPN). This can be done by relays or by a transistor-sourced signal. If a 5 volt device is used in combination with an IC-332, it must be connected as a 10-28 volt device. Reader
Reader
Sensor
Sensor
10-28 Volt Devices To trigger a 10-28 volt device, a small amount of current needs to flow from “Trigger +” to “Trigger –”. If a PNP source is used, “Trigger –” must be connected to “signal ground”. If an NPN source is used, “Trigger +” must be connected to the supply voltage. Reader
Reader
Sensor
Reader
Sensor
Sensor
PNP
A-12
NPN
MS-2 CCD Reader User’s Manual