Appendices

Appendix H, Glossary of Terms Aberration, The failure of an optical lens to produce an exact point-to-point correspondence between the object and its resulting image. Various types are chromatic, spherical, coma, astigmatism and distortion. Absorption, The loss of light of certain wavelengths as it passes through a material and is converted to heat or other forms of energy. (–) Active Illumination, Lighting an area with a light source coordinated with the acquisition of an image. Strobed flash tubes and pulsed lasers are examples. ADC, See Analog-to-Digital Converter. A/D Converter, See Analog-to-Digital Converter. AGC, See Automatic Gain Control. Ambient Light, Light which is present in the environment of the front end of a reader and generated from outside sources. This light, unless used for actual illumination, will be treated as background noise by the reader. Analog, A smooth, continuous voltage or current signal or function whose magnitude (value) is the information. Analog-to-Digital Converter (A/D Converter or ADC), A device that converts an analog voltage or current signal to a discrete series of digitally encoded numbers (signal) for computer processing. Application-Specific Integrated Circuit (ASIC), An integrated circuit that is customized for a particular kind of use, rather than general use. All vision system elements including firmware can be integrated into one ASIC. Automatic Gain Control (AGC), Adjustment to signal strength that seeks to maintain a constant level regardless of the distance between a reader and symbol. Auxiliary Port, RS-232 connection to an auxiliary terminal or device for remote viewing. Baud Rate, The number of discrete signal events per second; bits per second. CCD, See Charge-Coupled Device. Charge-Coupled Device (CCD), A semiconductor device with an array of light-sensitive elements that converts light images into electrical signals. Check Character, A Modulus 43 or Modulus 10 character that is added to encoded symbol data for additional data integrity. Connector, A plug or socket on a device or cable providing in/out connectivity for various circuits and pins. Concentrator, Intermediary device that relays data from readers to a host and commands from the host to the readers or other devices. DAC, See Digital-to-Analog Converter. Daisy Chain, Linkage of primary and secondary readers allowing data to be relayed up to the host via auxiliary port connections. Decode, A Good Read. The successful interpretation and output of the information encoded in a symbol. Default, Restores ROM or flash settings and initializes serial commands. MS-2 CCD Reader User’s Manual

A-13

Page 112

Glossary of Terms Delimited, A delimited command or field is bracketed by predefined characters. Decode Rate, The number of good reads per second ahieved by a reader. Darkfield Illumination, Lighting of objects, surfaces, or particles at very shallow or low angles, so that light does not directly enter a reader’s optical hardware. Depth-of-Field, The in-focus range of a reader. Measured from the distance behind an object to the distance in front of the object with all objects appearing in focus. Diffused Lighting, Scattered soft lighting from a wide variety of angles used to eliminate shadows and specular glints from profiled, highly reflective surfaces. Digital-to-Analog Converter (DAC), A VLSI circuit used to convert digitally processed images to analog for display on a monitor. Digital Signal Processor (DSP), A VLSI chip designed for ultra-high-speed arithmetic processing. Discrete I/O, Inputs and outputs characterized by discrete signal transitions from one voltage level to another so that digital switching can occur. Direct Memory Access (DMA), A capability provided by some computer bus architectures that allows data to be sent directly to memory from an attached device. DSP, See Digital Signal Processor. EPROM, See Erasable Programmable Read-Only Memory. Embedded Memory, Onboard memory device such as EPROM or flash. End of Read Cycle, The time or condition at which the reader stops expecting symbol information to decode. Erasable Programmable Read-Only Memory (EPROM), A memory chip that retains data when its power supply is turned off; “non-volatile memory”. External Edge, Allows a read cycle to be initiated by a trigger signal from an object detector when it detects the appearance of an object (rising edge). The read cycle ends with a good read, a timeout, or a new trigger. External Level, Allows a read cycle to be initiated by a trigger signal from an object detector. The read cycle ends when the object moves out of the detector’s range. Falling Edge, A change of state (to inactive) associated with a level trigger. Field-Programmable Gate Array (FPGA), A semiconductor device containing programmable interconnects and logic components. Firmware, Software hard-coded in non-volatile memory (ROM), and closely tied to specific pieces of hardware. Fixed Symbol Length, Increases data integrity by ensuring that only a symbol length will be accepted. Focal Distance, In optics, the distance from the lens to the focal plane. Focal Plane, Usually found at the image sensor, it is a plane perpendicular to the lens axis at the point of focus (–). Focus, Any given point in an image at which light converges; the focal point. FPGA, See Field-Programmable Gate Array. Full Duplex, A communications system in which signals can travel simultaneously between devices. A-14

MS-2 CCD Reader User’s Manual

Page 113

Appendices Good Read, A decode. The successful scanning and decoding of the information encoded in a bar code symbol. Half Duplex, A communications system in which signals can travel between devices in both directions, but not simultaneously. Host, A computer, PLC, or other device that is used to execute commands and process data and discrete signals. Image Sensor, A device that converts a visual image to an electrical signal; a CCD, for example. Initialize, Implement serial configuration commands into the reader’s active memory. Input, A channel or communications line. Decoded data or a discrete signal that is received by a device. Ladder Orientation, A linear symbol orientation in which the bars are parallel to the symbol’s direction of travel. Light-Emitting Diode (LED), A semiconductor device that emits light when conducting current. Lens, A transparent piece of material with curved surfaces which either converge or diverge light rays. Multidrop, A communications protocol for networking two or more readers or other devices with a concentrator (or controller) and characterized by the use of individual device addresses and the RS-485 standard. Normally Closed, A discrete output state that is only active when open. Normally Open, A discrete output state that is only active when closed. Object Plane, An imaginary plane in the field of view, focused by a reader’s optical system at the corresponding image plane on the sensor. Output, A channel or communications line. Data or discrete signals that are transmitted or displayed by a device. Parity, An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd. Picket Fence Orientation, A linear symbol orientation in which the bars are perpendicular to the symbol’s direction of travel. Pitch, Rotation of a linear or 2D symbol around an axis parallel to the symbol length on the substrate. See the illustration below. Bar code label axis Skew

Tilt axis Tilt

Symbol Scanner

Pitch Pitch axis

Reader

Scan line

MS-2 CCD Reader User’s Manual

A-15

Page 114

Glossary of Terms PLC, See Programmable Logic Controller. Port, Logical circuit for data entry and exit. (One or more ports may be included within a single connector.) Programmable Logic Controller (PLC), An electronic device used in industrial automation environments such as factory assembly lines and automotive manufacturing facilities. Protocol, The rules for communication between devices, providing a means to control the orderly flow of information between linked devices. Random Access Memory (RAM), A data storage system used in computers, composed of integrated circuits that allow access to stored data in any sequence without movement of physical parts. Read Cycle, A programmed period of time or condition during which a reader will accept symbol input. Read-Only Memory (ROM), A data storage medium used in computers and other electronics, primarily used to distribute firmware. Skew, Rotation of a linear or 2D symbol around an axis parallel to the symbol height on the substrate. See the illustration under the definition of Pitch. Substrate, The surface upon which a symbol is printed, stamped, or etched. Symbol Transitions, The transition of bars and spaces on a symbol, used to detect the presence of a symbol on an object. Symbology, A symbol type, such as Code 39 or Code 128, with special rules to define the widths and positions of bars and spaces to represent specific numeric or alphanumeric information. Tilt, Rotation of a linear or 2D symbol around an axis perpendicular to the substrate. See the illustration under the definition of Pitch. Trigger, A signal, transition, or character string that initiates a read cycle. Very Large-Scale Integration (VLSI), The creation of integrated circuits by combining thousands of transistor-based circuits on a single chip. VLSI, See Very Large-Scale Integration.

A-16

MS-2 CCD Reader User’s Manual

Page 115

Hyperlink Index A A/D Converter Aberration About the MS-2 CCD Reader About This Manual Absorption Active Illumination ADC Add / Remove Exception Add Macro Advanced Options AGC Ambient Light Analog Analog-to-Digital Converter Appendices Application Mode Application Record Separator Character (Code 128/EAN 128) Application-Specific Integrated Circuit ASCII Table Ask to Save ESP File when Quitting Autoconnect Automatic Gain Control Auxiliary Port

B Bar Code Options Baud Rate Baud Rate, Host Port Begin Transmission

C Capture Text CCD CE Mark Change Background Color Change Echo Font Change Font Change Keyboard Macros MS-2 CCD Reader User’s Manual

1

Page 116

D Charge-Coupled Device Check Character Check Character Mode (MSI Code) Check Character Output (Codabar) Check Character Output Status (Code 39) Check Character Output Status (Industrial 2 of 5) Check Character Output Status (Interleaved 2 of 5) Check Character Output Status (MSI Code) Check Character Output Status (Plessey Code) Check Character Status (Codabar) Check Character Status (Code 39) Check Character Status (Industrial 2 of 5) Check Character Status (Interleaved 2 of 5) Check Hardware Cleaning the Imager Clear Codabar Code 128 / EAN 128 Code 39 Code 93 Communications Communications by ESP Communications Protocol Communications Protocol Command Table Communications Serial Commands Concatenating Configuration Commands Concentrator Configuration Command Status Configuration Command Status Request Configuration Setting Changes Configure the Reader Connect the System Connect to Readers via TCP/IP Connecting by RS-232 Connecting by USB Connector Continuous Read Continuous Read 1 Output Emulation Control Characters Copy

D DAC Daisy Chain

2

MS-2 CCD Reader User’s Manual

Page 117

E

Index

Darkfield Illumination Data Bits, Host Port DataBar Expanded (RSS Expanded) DataBar Limited (RSS Limited) DataBar-14 (RSS-14) Decode Decode Rate Decodes Before Output Default Default / Reset / Save Default Macros Default Settings Defaulting Delimited Depth-of-Field Design Device Control Differences from Default Diffused Lighting Digital Signal Processor Digital-to-Analog Converter Direct Memory Access Disable Reader Disclaimer Discrete I/O Display Incoming Data Even When Not in Focus Document Memo Downloading Application Code Downloading ESP from the Web DSP

E EAN-13 Status (UPC/EAN) EAN-8 as EAN-13 (UPC/EAN) EAN-8 Status (UPC/EAN) Editing a Macro Effects of Protocol Commands Electrical Electrical Specifications Embedded Memory Enable Echo Enable Reader End of Read Cycle Enhanced Format MS-2 CCD Reader User’s Manual

3

Page 118

F Entering Control Characters in Serial Commands Environmental EPROM Erasable Programmable Read-Only Memory ESP System Requirements Explanation of Modifiers for Code 39, Codabar, and I-2/5 Explanation of Modifiers for Other Symbologies External Edge External Level EZ Mode

F Falling Edge Field-Programmable Gate Array File Find Find Next Find Previous Firmware Firmware Update Firmware Verification FIS Options Fixed Length Fixed Symbol Length Fixed Symbol Length Status (DataBar Expanded) Focal Distance Focal Plane Focus Force Connect Format (Industrial 2 of 5) FPGA Full ASCII Set (Code 39) Full Duplex Function Keys

G General Specifications Glossary of Terms Good Read GS1 DataBar (RSS)

4

MS-2 CCD Reader User’s Manual

Page 119

H

Index

H Half Duplex Hex Values High Density Highlighting Host Host Communications Host Connector / Pin Assignments Host Port Connections Host Port Protocol

I Image Sensor Import/Export Industrial 2 of 5 Initialize Input Install ESP Installing ESP from the Microscan Tools CD Interleaved 2 of 5 ISO Certification

K Keyboard Macros

L Ladder Orientation Latest Manual Version Lens Light Emitting Diode Limitation of Liability Low Density

M Macros Maximum Speed Mechanical Menu Toolbar Microscan ESP Help Minimum Length Minimum Speed MS-2 CCD Reader User’s Manual

5

Page 120

N Minimum Symbol Length (Code 128/EAN 128) Minimum Symbol Length (Code 39) Minimum Symbol Length (Code 93) Minimum Symbol Length (MSI Code) Minimum Symbol Length (Plessey Code) Model Model Memo Mounting the Imager MS-2 CCD Reader MS-2 CCD Reader Dimensions MS-2 Read Cycle Overview MSI Code Multidrop

N Navigating in ESP New ESP File New Model Next Row No Decode Timeout No Read Message No Read Status Non-Printable Characters Normally Closed Normally Open Number of Symbols

O Object Plane Open/Save Operational Tips Options Output

P Parity Parity, Host Port Paste Pause Picket Fence Orientation Pitch PLC

6