Page 81

Symbologies

Pharmacode Read the following symbols to enable/disable Pharmacode settings: Pharmacode Off (Default)

Pharmacode On Save Settings

Pharmacode by ESP

Fixed Symbol Length Status When enabled, the imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid. Symbol Length Specifies the exact number of bars that must be present for the imager to recognize and decode the Pharmacode symbol. Minimum Bars Sets the minimum number of bars that a Pharmacode symbol must have to be considered valid. Bar Width Status If set to Mixed, the imager will autodiscriminate between narrow bars and wide bars. If set to All Narrow, all bars will be considered as narrow bars. If set to All Wide, all bars will be considered as wide bars. If set to Fixed Threshold, it will use the fixed threshold value to determine whether the bars are narrow or wide. The Bar Width Status setting will be ignored when the imager is able to tell the difference between the narrow and the wide bars. Mobile Hawk Handheld DPM Imager User Manual

6-15

Page 82

Pharmacode Direction Specifies the direction in which a symbol can be read. Fixed Threshold Value Used when Bar Width Status is set to Fixed Threshold. Defines the minimum difference in pixels that will distinguish a narrow bar from a wide bar.

Sample Pharmacode Symbol

6-16

Mobile Hawk Handheld DPM Imager User Manual

Page 83

Symbologies

QR Code Read the following symbols to configure QR Code settings: QR Code On

QR Code and Micro QR Code Off

Micro QR On

QR Code and Micro QR Code On (Default)

Save Settings

QR Code by ESP

Sample QR Code Symbol

Sample Micro QR Code Symbol

Mobile Hawk Handheld DPM Imager User Manual

6-17

Page 84

UPC/EAN

UPC/EAN Read the following symbols to configure UPC/EAN settings: UPC On (Default)

UPC Off

UPC Expansion On (Default)

UPC Expansion Off

EAN On (Default)

EAN Off

Save Settings

UPC/EAN by ESP

Sample UPC-E Symbol

Sample UPC-A Symbol

6-18

Mobile Hawk Handheld DPM Imager User Manual

Page 85

Symbologies

Symbology Identifier When Symbology Identifier is enabled, an AIM (Association for Automatic Identification and Mobility) preamble is added to decoded data output (see the AIM Symbology Identifiers list). This preamble identifies what kind of symbology has been decoded.

Symbology Identifier On

Symbology Identifier Off (Default)

Save Settings

Symbology Identifier by ESP

AIM Symbology Identifiers A

Code 39

C

Code 128 d

Data Matrix e

GS1 DataBar / Composite

E

UPC/EAN

F

Codabar

G

Code 93

I

Interleaved 2 of 5

L

PDF417 / MicroPDF417

Q

QR Code / Micro QR Code

X

Other (Pharmacode)

z

Aztec

Mobile Hawk Handheld DPM Imager User Manual

6-19

Page 86

Symbology Identifier

6-20

Mobile Hawk Handheld DPM Imager User Manual

Page 87

7 I/O Parameters Contents I/O Parameters by ESP.................................................................................................................7-2 Operational Feedback...................................................................................................................7-3 Gain Control ..................................................................................................................................7-4 Exposure .......................................................................................................................................7-5 Data Validation..............................................................................................................................7-6

This section contains information on how to set your imager to the most efficient and effective parameters for your application.

Mobile Hawk Handheld DPM Imager User Manual

7-1

Page 88

I/O Parameters by ESP

I/O Parameters by ESP To make changes to configuration settings in the I/O Parameters tree control: 1. Left click on the + to expand the tree.

2. Double click on the parameter and click once in the selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change and click once on the setting.

7-2

4. Left click again on the open screen to complete the selection. 5. Right click on the open screen and select Save to Reader to implement the command in the imager.

Mobile Hawk Handheld DPM Imager User Manual

Page 89

I/O Parameters

Operational Feedback Sound/Vibration

Condition Successful Power-On

1 Beep / Vibration

Successful Connection with Host via USB Successful Decode and Data Transfer to Host

1 Beep / Vibration 1 Beep / Vibration 2 Beeps / Vibrations separated by short pause

Configuration Symbol Successfully Decoded and Processed

LED

Sequence: AMBER GREEN AMBER None Flash GREEN Flash GREEN

Beep and Vibration Modes Read the following symbols to set beep and vibration modes.

Vibrate On / Beep On (Default)

Vibrate On / Beep Off

Vibrate Off / Beep On

Save Settings

Mobile Hawk Handheld DPM Imager User Manual

7-3

Page 90

Gain Control

Gain Control

Gain Control is a system that controls gain in the captured image - how bright or dark the resulting image will be. The higher the gain, the brighter the image. When the Mobile Hawk is set to Adaptive mode, it will automatically maintain the proper setting for gain based on the captured image in order to produce the best setting to perform a decode. In the Manual setting the gain is fixed to whatever value is set by gain slider controls on the Illumination tab in I/O Parameters.

7-4

Mobile Hawk Handheld DPM Imager User Manual