Page 91
I/O Parameters
Exposure The larger the Exposure value, the longer the pixels in the candidate image are exposed, allowing the imager to collect more light. Note: A larger exposure value may cause blurred images.
Mobile Hawk Handheld DPM Imager User Manual
7-5
Page 92
Data Validation
Data Validation Data Validation is used to confirm that a decoded string from the imager has complied with a particular company, industry, or ISO standard. Mobile Hawk Data Validation is compliant with Department of Defense Unique Identification and ISO/IEC 15434 (Information Technology – Transfer Syntax for High-Capacity ADC Media) requirements.
Unique Identification Unique Identification is a mandatory Department of Defense (DoD) requirement on all solicitations issued January 1, 2004 or later. This policy mandates the use of Unique Item Identifiers (UIIs) encoded within Data Matrix symbols on equipment and parts procured by DoD. The Mobile Hawk complies with Department of Defense Standard Practice Identification (MIL-STD-130). Once the imager decodes the Data Matrix symbol, and if Unique Item Identifier (UII), Current Part Number (CPN), and Lot/Batch Number (LBN) are turned on, the Mobile Hawk checks the ISO/IEC 15434 syntax with ISO/IEC 15418 (ANSI MH10.8.2 – AI and DI) and ISO/IEC 21849 (ATA – TEI) semantics to construct the UII, CPN, and LBN.
Unique Identification Features The following data output options are applicable to Data Matrix ECC 200 symbols only and have no effect on other symbologies.
7-6
UII Enabled
Allows the imager to read only message streams encoded in Data Matrix ECC 200 symbols, then to construct and output a UII string. The message streams include validation of Unique Item Identifier (UII), Current Part Number (CPN), and Lot/Batch Number (LBN) strings. When the imager decodes a symbol but the symbol data does not compy with UII format, it will stop capturing images and the green LED will illuminate without beeping, vibrating, or outputing the string.
UII Enabled with Pass Through
Allows the imager to read UII messages in Data Matrix ECC 200 symbols and non-UII messages in any type of symbols. The imager’s behavior is the same as with UII Enabled.
UII Enabled with Error Messages
Allows the imager to read UII messages in Data Matrix ECC 200 symbols and output detailed information such as construction type, data components, or error messages. The imager’s behavior is the same as with UII Enabled.
Data Validation Disabled
Disables both UII and ISO/IEC 15434 data validation.
Mobile Hawk Handheld DPM Imager User Manual
Page 93
I/O Parameters
Unique Identification Output Examples UII Enabled UII:UN123456789ABCDEFG CPN:87654321 LBN:87654321 UII:12345678 CPN:87654321 UII:12345678 LBN:87654321
UII Enabled with Pass Through UII:UN123456789ABCDEFG CPN:87654321 LBN:87654321 UII:12345678 CPN:87654321 UII:12345678 LBN:87654321 DATA:Microscan Precision Data Acquisition and Control Solutions
UII Enabled with Error Messages UII:UN123456789ABCDEFG;Construct_1;25SUN123456789ABCDEFG;;;;;; CPN:87654321;PNR;PNR 87654321;;;;;; LBN:87654321;30T;30T87654321;;;;;; UII:12345678 CPN:87654321;Construct_1_2/PNR;UID 12345678;PNR 87654321;;;;; UII:12345678 LBN:87654321;Construct_1/30T;25S12345678;30T87654321;;;;; (15434 ERROR: HEADER - 1ST POSITION);Microscan Precision Data Acquisition and Control Solutions;;;;;;;
Data Validation Disabled The imager will return to normal output behavior without performing data validation.
Mobile Hawk Handheld DPM Imager User Manual
7-7
Page 94
Data Validation
ISO/IEC 15434 ISO/IEC 15434 specifies a transfer structure, syntax, and coding of messages and data formats when using high capacity automatic data capture (ADC) technologies. The following ISO/IEC 15434 data output options are applicable to Data Matrix ECC 200 symbols only and have no effect on other symbologies. ISO/IEC 15434 Enabled
ISO/IEC 15434 Enabled with Error Messages Data Validation Disabled
Allows the imager to read only ISO/IEC 15434-compliant message streams in Data Matrix ECC 200 symbols then output the ISO/IEC 15434 string. This implementation only checks the header/trailer format and proper format indicator (00-99 and DD). The output string has a prefix, a format indicator, and data components. Allows the imager to read only ISO/IEC 15434-compliant messages in Data Matrix ECC 200 symbols and output detailed information such as prefix, format indicator, data components, or error messages. Disables both UII and ISO/IEC 15434 data validation.
ISO/IEC 15434 Output Examples ISO/IEC 15434 Enabled (15434);05;0100061414199999;211A0B9C3D6;;;;; (15434);06;7L0A1B3C;1P4202435;S10936;;;; (15434);06;17V0A1B2;1P4202435;S10936;;;;
ISO/IEC 15434 Enabled with Error Messages (15434);05;0100061414199999;211A0B9C3D6;;;;; (15434);06;7L0A1B3C;1P4202435;S10936;;;; (15434);06;17V0A1B2;1P4202435;S10936;;;; (15434 ERROR: HEADER - 3RD POSITION);[)<▲DD↔CAG 12345↔SER 67890123▲♦;;;;;;; (15434 ERROR: TRAILER - END OF TRANSMISSION);[)>▲12↔CAG 12345↔SER 67890123▲♣;;;;;;; (15434 ERROR: HEADER - GROUP SEPARATOR);[)>▲12▲CAG 12345♦029SER 67890123▲♦;;;;;;;
Data Validation Disabled The imager will return to normal output behavior without performing data validation.
7-8
Mobile Hawk Handheld DPM Imager User Manual
Page 95
I/O Parameters
Data Validation Settings The following symbols control Data Validation functions: UII Enabled
UII Enabled with Pass Through
UII Enabled with Error Messages
ISO/IEC 15434 Enabled
ISO/IEC 15434 Enabled with Error Messages
Data Validation Disabled (Default)
Save Settings
Data Validation by ESP Each of the Data Validation Settings can also be enabled in ESP’s I/O Parameters tree control.
Mobile Hawk Handheld DPM Imager User Manual
7-9
Page 96
Data Validation
Detailed Output Format The table below describes data validation output in detail. Note: UII Enabled with Pass Through will add the prefix DATA to non-UII output for all symbologies. Note: UII Enabled with Error Messages will output the following format: UII/CPN/LBN; DF0; DF1; DF2; DF3; DF4; DF5; DF6; DF7. Note: When ISO/IEC 15434 output is in compliance with the standard, the format is (15434); DF0; DF1; DF2; DF3; DF4; DF5; DF6; DF7. When it is not in compliance with the standard, the output is (15434 ERROR: xxxx);;;;;;;; where DF0 is the format indicator showing which type of data qualifier is in use. UII Enabled Content of Decoded Data Matrix Symbol Valid UII Valid CPN Valid LBN
Valid UII and CPN Valid UII and LBN
Valid UII and Invalid CPN Valid UII and Invalid LBN
Invalid UII and Valid CPN Invalid UII and Valid LBN None of the above (Invalid UII; Invalid CPN; Invalid LBN; Invalid UII and Invalid CPN; Invalid UII and Invalid LBN)
7-10
UII/CPN/LBN UII:UII_data Example: UII:12345678 CPN:CPN_data Example: CPN:87654321 LBN:LBN_data Example: LBN:87654321 UII:UII_data CPN:CPN_data Example: UII:12345678 CPN:87654321 UII:UII_data LBN:LBN_data Example: UII:12345678 LBN:87654321 UII:UII_data (CPN ERROR) Example: UII:12345678 (CPN ERROR) UII:UII_data (LBN ERROR) Example: UII:12345678 (LBN ERROR) (UII ERROR) CPN:CPN_data Example: (UII ERROR) CPN:87654321 (UII ERROR) LBN:LBN_data Example: (UII ERROR) LBN:87654321 No output data
Mobile Hawk Handheld DPM Imager User Manual
Page 97
I/O Parameters UII Enabled with Error Messages Content of Decoded Data UII/CPN/LBN Matrix Symbol UII:UII_data Valid UII Example: UII:12345678 CPN:CPN_data Example: CPN:87654321 Valid CPN LBN:LBN_data Valid LBN Example: LBN:87654321 UII:UII_data CPN:CPN_data Example: UII:12345678 CPN:87654321 Valid UII and CPN UII:UII_data LBN:LBN_data Valid UII and LBN Example: UII:12345678 LBN:87654321 UII:UII_data (30P ERROR: xxxx) UII:UII_data (PNR ERROR: xxxx) Valid UII and Invalid CPN UII:UII_data (240 ERROR: Valid UII and Invalid LBN xxxx) UII:UII_data (30T ERROR: xxxx) Invalid UII and Valid CPN Invalid UII and Valid LBN
Invalid UII
Invalid CPN Invalid LBN
Invalid UII and Invalid CPN Invalid UII and Invalid LBN
(UII ERROR: xxxx) CPN:CPN_data (UII ERROR: xxxx) LBN:LBN_data (UII ERROR: xxxx) (15434 ERROR: xxxx) Example: (UII ERROR: DATA ELEMENT CHARACTER) (30P ERROR:xxxx) (PNR ERROR:xxxx) (240 ERROR:xxxx) (30T ERROR:xxxx) (15434 ERROR: xxxx) (UII ERROR: xxxx) (30P ERROR: xxxx) (UII ERROR: xxxx) (PNR ERROR: xxxx) (UII ERROR: xxxx) (240 ERROR: xxxx) (UII ERROR: xxxx) (30T ERROR: xxxx)
Mobile Hawk Handheld DPM Imager User Manual
DFO Constructed UII type Example: Contruct_1 Constructed CPN type Example: PNR Constructed LBN type Example: 30T Constructed UII/CPN type Example: Construct_1/PNR Constructed UII/LBN type Example: Construct_1/30T
Constructed UII type Example: Construct_1
Constructed CPN type: 30P, PNR, 240 Constructed LBN type: 30T Original decoded data
Original decoded data
Original decoded data
7-11
Page 98
Data Validation
Error Messages The following is a list of potential error messages. 15434 ERROR: DATA ELEMENT SEPARATOR 15434 ERROR: DOUBLE TRAILER 15434 ERROR: FORMAT INDICATOR 15434 ERROR: HEADER - 1ST POSITION 15434 ERROR: HEADER - 2ND POSITION 15434 ERROR: HEADER - 3RD POSITION 15434 ERROR: HEADER - 4TH POSITION 15434 ERROR: HEADER - GROUP SEPARATOR 15434 ERROR: TRAILER - END OF TRANSMISSION 15434 ERROR: TRAILER - RECORD SEPARATOR PNR ERROR: TOO LONG PNR ERROR: TOO SHORT PNR ERROR: CHARACTER 30P ERROR: TOO LONG 30P ERROR: TOO SHORT 30P ERROR: CHARACTER 240 ERROR: TOO LONG 240 ERROR: TOO SHORT 240 ERROR: CHARACTER UII ERROR: DATA ELEMENT CHARACTER UII ERROR: DATA ELEMENT TOO LONG UII ERROR: DATA ELEMENT TOO SHORT UII ERROR: LOWER CASE CHARACTER UII ERROR: NEED UII ELEMENT FIRST UII ERROR: SPACE AFTER TEI DATA QUALIFIER UII ERROR: TEI DATA QUALIFIER UII ERROR: UII ELEMENT INCOMPLETE UII ERROR: WRONG FORMAT INDICATOR UII ERROR: UII STRING TOO LONG
Additional Notes • DF1 – DF7: If the UII/CPN field is “(15434 ERROR: xxxx)”, DF1 – DF7 are filled in with an empty string. Otherwise, the fields are used to display data elements. If there are fewer than seven data elements, an empty string is filled in at the end. If there are more than seven elements, only the first seven elements are displayed. • There is a space between UII and CPN in both tables (UII:12345678 CPN:87654321). • The constructed UII type can be Contruct_1, Contruct_2, Construct_1_2, or IUID_EQUIVALENT. • The constructed CPN type can be PNR, 30P, or 240. The constructed LBN type can be 30T.
7-12
Mobile Hawk Handheld DPM Imager User Manual
Page 99
8 Advanced Operations Contents Dot Peen Enhanced Illumination Settings .................................................................................... 8-2 Illumination Settings by ESP ........................................................................................................ 8-3 Lock Settings ................................................................................................................................ 8-6
This section introduces several settings that can be applied to speed up processing or improve readability in various circumstances.
Mobile Hawk Handheld DPM Imager User Manual
8-1
Page 100
Dot Peen Enhanced Illumination Settings
Dot Peen Enhanced Illumination Settings The Mobile Hawk’s Dot Peen Enhanced illumination settings can be controlled using the configuration symbols shown here. They can also be controlled in ESP’s EZ Mode. Note: The illumination default mode will reset the imager’s illumination settings to factory default.
Illumination Default Mode
Dot Peen Enhanced Illumination Mode - Large Mark
Dot Peen Enhanced Illumination Mode - Medium Mark
Dot Peen Enhanced Illumination Mode - Small Mark
Save Settings
8-2
Mobile Hawk Handheld DPM Imager User Manual