Page 81

Calibration

Medium Pass The theory behind Medium Pass is to develop a readable range from which to dial in a decoded symbol. Running Medium Pass Prog

Rating

Decode

Quality

Focus

Shutter

Gain

Locate

51 53 55 57 59 61 63 65 67 69 71 73 75

4216 8436 6336 8448 8456 8464 8472 8488 8504 8512 8528 8584 8644

2 4 3 4 4 4 4 4 4 4 4 4 4

8 20 24 32 40 48 56 72 88 96 112 168 228

386 386 386 386 386 386 386 386 386 386 386 386 386

250 250 250 250 250 250 250 250 250 250 250 250 250

0 4 8 12 16 20 24 28 32 36 40 44 48

5 4 4 4 5 4 5 5 5 5 6 5 5

Rating List (Best): Rating = 8606; Focus = 386; Shutter = 250; Gain = 48 Rating = 8581; Focus = 386; Shutter = 250; Gain = 44 Rating = 8553; Focus = 386; Shutter = 250; Gain = 40 Rating = 8527; Focus = 386; Shutter = 250; Gain = 36 Rating = 8505; Focus = 386; Shutter = 250; Gain = 32 Rating = 8488; Focus = 386; Shutter = 250; Gain = 28 Rating = 8476; Focus = 386; Shutter = 250; Gain = 24

MINI Hawk Xi High Performance Imager User Manual

4-17

Page 82

Initiating Calibration

Fine-Tune Pass The theory behind Fine-Tune Pass is to dial in a decoded symbol based on the range supplied by the Medium Pass. Running Fine Tune Pass Prog

Rating

Decode

Quality

Focus

Shutter

Gain

Locate

77 79 81 84 86 88 90 93 95 97 100

6416 6424 6424 6432 6448 6464 6476 6488 6506 6524 6538

3 3 3 3 3 3 3 3 3 3 3

104 112 112 120 136 152 164 176 194 212 226

386 386 386 386 386 386 386 386 386 386 386

250 250 250 250 250 250 250 250 250 250 250

38 39 40 41 42 43 44 45 46 47 48

7 6 6 6 5 5 5 5 6 5 6

Rating List (Best): Rating = 6527; Focus = 386; Shutter = 250; Gain = 48 Rating = 6517; Focus = 386; Shutter = 250; Gain = 47 Rating = 6505; Focus = 386; Shutter = 250; Gain = 46 Rating = 6491; Focus = 386; Shutter = 250; Gain = 45 Rating = 6476; Focus = 386; Shutter = 250; Gain = 44 Rating = 6462; Focus = 386; Shutter = 250; Gain = 43 Rating = 6449; Focus = 386; Shutter = 250; Gain = 42 Calibration PASSED.

4-18

MINI Hawk Xi High Performance Imager User Manual

Page 83

Calibration

Additional Notes about Calibration The following conditions apply to the imager’s calibration process. Some of these items are noted at various points throughout this section, or in other sections of the imager’s documentation. 1. A symbol must be in the imager’s field of view during the calibration process. 2. The Illumination Brightness parameter <K514> is not part of the calibration process. 3. Background Color <K451> is calibrated. 4. If Window of Interest Framing is enabled, the WOI will be set to full frame when calibration begins. If WOI Framing is disabled, the current WOI configuration will be used for the Search Pass. 5. If Symbol Type is enabled for calibration (Autodiscriminate), then Interleaved 2 of 5 Range Mode Status (Interleaved 2 of 5) <K472> will be enabled. This allows variable-length Interleaved 2 of 5 symbols to be decoded. If an Interleaved 2 of 5 symbol is decoded during calibration, then code length # 1 will be set to the decoded symbol length at the end of calibration. Otherwise, the symbol lengths will be restored to their original configurations. 6. Pharmacode is not calibrated. 7. All symbol types that were enabled before calibration will still be enabled after calibration. For example, if Data Matrix ECC 200 was enabled before calibration, and the calibration routine was performed on a Code 128 symbol, then after calibration is completed both Data Matrix ECC 200 and Code 128 will be enabled. 8. The calibration process does not modify the global Composite status <K453>. The global Composite status must be configured properly before calibration. 9. If the user requires calibration of a stacked symbology <K482>, <K483>, or <K484>, that symbology must be enabled and configured appropriately before calibration. 10. UPC Supplementals will be disabled during calibration. 11. The Search process will use the configurable Window of Interest for image captures. However, when the search process is completed, the WOI will be reduced to include only the symbol of interest and some additional boundary area.

MINI Hawk Xi High Performance Imager User Manual

4-19

Page 84

Additional Notes about Calibration

4-20

MINI Hawk Xi High Performance Imager User Manual

Page 85

5 Read Cycle Contents Read Cycle by ESP ...................................................................................................................... 5-2 Read Cycle Serial Commands...................................................................................................... 5-3 Read Cycle Setup......................................................................................................................... 5-4 Multisymbol................................................................................................................................... 5-5 Trigger Mode and Filter Duration.................................................................................................. 5-6 External Trigger Polarity ............................................................................................................. 5-11 Serial Trigger .............................................................................................................................. 5-12 Start Trigger Character (Non-Delimited)..................................................................................... 5-13 Stop Trigger Character (Non-Delimited) ..................................................................................... 5-14 End of Read Cycle...................................................................................................................... 5-15 Capture Mode ............................................................................................................................. 5-17 Capture Timing ........................................................................................................................... 5-21 Image Processing Timeout ......................................................................................................... 5-23 Image Storage ............................................................................................................................ 5-24 Decodes Before Output .............................................................................................................. 5-26 Setting Up the Imager for EZ Trax.............................................................................................. 5-27

After you’ve established communications and completed basic read rate testing, you will need to address the spatial and timing parameters associated with your application. This section explains those parameters.

MINI Hawk Xi High Performance Imager User Manual

5-1

Page 86

Read Cycle by ESP

Read Cycle by ESP

Click the Parameters button and then the Read Cycle tab.

To open nested options, single-click the +.

5-2

To change a setting, double-click the setting and use your cursor to scroll through the options.

MINI Hawk Xi High Performance Imager User Manual

Page 87

Read Cycle

Read Cycle Serial Commands Trigger Mode/Filter Duration <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> Serial Trigger Character <K201,serial trigger character> External Trigger State <K202,external trigger state> End of Read Cycle <K220,end of read cycle,read cycle timeout> Decodes Before Output <K221,decodes before output> Multisymbol <K222,number of symbols,multisymbol separator> Start Trigger Character <K229,start character> Stop Trigger Character <K230,stop character> Capture Mode <K241,capture mode,number of captures,rapid capture mode> Capture Timing <K242,time before first capture,time between first and second captures,,,,,,,,time between seventh and eighth captures> Image Storage <K244,image storage type,image store mode> IP Timeout <K245,image processing timeout>

MINI Hawk Xi High Performance Imager User Manual

5-3

Page 88

Read Cycle Setup

Read Cycle Setup Setting up read cycle and triggering parameters will involve a series of decisions based on your particular application, as follows: 1. Select the number of symbols to be read in a single cycle. The MINI Hawk Xi can read multiple symbols in a single image frame. 2. Decide on the trigger type to be used: if serial, choose a serial character; if external, choose either Level or Edge. 3. Designate how the read cycle should end (Timeout, New Trigger, Last Frame). 4. Select Capture Mode, Continuous Mode, or Rapid Mode. 5. Select Number of Captures (if in Rapid Capture Mode). 6. Set the Time Before First Capture and Time Between Captures, if any. Note: The imager’s camera captures images at a rate of about 16/second (based on a 1280 x 1024 image). The capture rate increases as frame sizes decrease. Note: If you need to set up your MINI Hawk Xi for use with EZ Trax software, see Setting Up the Imager for EZ Trax.

5-4

MINI Hawk Xi High Performance Imager User Manual

Page 89

Read Cycle

Multisymbol Usage: Definition: Conditions:

Multisymbol is commonly used in shipping applications where a shipping symbol contains individual symbols for part number, quantity, etc. This feature allows on trigger to pick up all the symbols. Multisymbol allows the user to define up to 100 symbols that can be read in a single read cycle. The following conditions apply: • Each symbol must be different to be read, unless in Rapid Capture Mode, configured for “triggered capture”. • The maximum number of characters in a read cycle is 3,000 for all symbols. • All No Read messages are posted at the end of the data string, unless output filtering is enabled. • If more than one symbol is within the field of view at the same time, symbol data may not be displayed in the order of appearance. • If Matchcode Type is set to Sequential or if Trigger is set to Continuous Read 1 Output, the imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.

Number of Symbols Definition: Serial Cmd: Default: Options:

Number of Symbols is the number of different symbols that can be read in a single read cycle. <K222,number of symbols, multisymbol separator> 1 1 to 100

Multisymbol Separator Usage: Definition:

Used to delimit or separate data fields with a user defined character. Any valid ASCII character, inserted between each symbol read when Multisymbol is set to any number greater than 1. Serial Cmd: <K222,number of symbols,multisymbol separator> Default: , (comma) Options: Any available ASCII character. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K222h,,3C> For >: <K222h,,3E> For , : <K222h,,2C> Note: If No Read messages are disabled and there are No Reads occurring, separators will only be inserted between symbol data outputs.

MINI Hawk Xi High Performance Imager User Manual

5-5

Page 90

Trigger Mode and Filter Duration

Trigger Mode and Filter Duration Trigger Mode Definition: Serial Cmd: Default: Options:

The Trigger is the event that initiates a read cycle. Note: When calibrating the imager or testing read rate, the current trigger setting will be disregarded. <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> Continuous Read 0 = Continuous Read 1 = Continuous Read 1 Output 2 = External Level 3 = External Edge 4 = Serial Data 5 = Serial Data and Edge

Continuous Read Usage: Definition:

Serial Cmd:

5-6

Continuous Read is useful in testing symbol readability or reader functions. It is not recommended for normal operations. In Continuous Read, trigger input options are disabled, the imager is always in the read cycle, and it will attempt to decode and transmit every capture. If a single symbol stays within read range for multiple read cycles, its data will be transmitted repeatedly until it leaves the read range. The imager sends replies to serial commands that require responses when symbol data is transmitted, or read cycle timeout is enabled and a timeout occurs and at least one captured image has been processed. Depending on the combination of enabled symbologies, the imager may take longer than the timeout to process a captured image. Note: When to Output and No Read options have no affect on Continuous Read. <K200,0>

MINI Hawk Xi High Performance Imager User Manual